6 floors · 144 apartments · 115,396 sq ft · built 1956 · class D4 · owner of record: Park Hill Owners Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 44 days | Annual |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-26 (Accepted). Agency page | Dec 31, 2026 in 44 days | 1 of 2 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 60 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 115,396 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 165 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 165 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 288 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1140 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2030) Likely applies Local Law 87 · Calendar year 2030 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5180). Agency page | Dec 31, 2030 in 1505 days | Next due 2030 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 1, 2021 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #811404.AGG1:PRIOR NOV 37013095P UNDER 28- #37021801N | Oct 26, 2021 ADMIT/IN-VIO | $0 |
| Oct 15, 2018 | Local Law CLASS - 2 FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #811404.RMDY: SUBMIT REQUIRED TECHNICAL REPORT. #37013095P | Sep 17, 2019 IN VIOLATION | $0 |
| Mar 21, 2008 | Plumbing Non-Hazardous USE OF INSTALLATION OF PLUMBING MATERIALS OR EQUIPMENT WHICH DOES NOT COMPLY W/RS-16. GAS DRYERS IN LAUNDRY ROOM MUST HAVE PIPE CONNECTIONS NOT FLEXIBLE GAS CONNECTIONS. REMEDY: REMOVE NON-COMPLYING MATERIAL #34609565Z | May 13, 2008 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2023 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023 #00067 | DOB VIOLATION - ACTIVE |
| Aug 21, 2012 | LL11/98-LOCAL LAW 11/98 - FACADE FILE UNSAFE REPORT CYCLE 7 #HAZ73689 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
| Feb 22, 2023 | Facades FISPNRF CYCLE 9B NO REPORT FILED | Active |
| Jul 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018 | Active |
| Aug 21, 2012 | Facades LL11/98 FILE UNSAFE REPORT CYCLE 7 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Apr 30, 2026 | A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Aug 3, 2026 |
| Aug 23, 2024 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND NORTH WALL AT BASEMENT AT LOBBY | Sep 27, 2024 |
| Aug 23, 2024 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND NORTH WALL AT BASEMENT AT LOBBY | Nov 26, 2024 |
| Aug 23, 2024 | B | § 27-2005 HMC: REFIT DOOR AND FRAME AT SOUTH 2 DOOR TO FIRE STAIRS LABELED ''B'' AT PUBLIC HALL, 3rd STORY | Sep 27, 2024 |
| Aug 23, 2024 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND NORTH WALL AT BASEMENT AT LOBBY | Nov 26, 2024 |
| Jun 13, 2023 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE BUILDING ENTRANCE DOOR , 1st STORY | Jun 27, 2023 |
| May 19, 2023 | C | Apt 5G · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 5G, 5th STORY, 4th APARTMENT FROM EAST AT SOUTH | May 25, 2023 |
| May 19, 2023 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE SOUTH 2 TO FIRE STAIRS AT SOUTH SECTION AT PUBLIC HALL, 5th STORY | Jun 2, 2023 |
| Jan 23, 2023 | C | § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE SELF CLOSING HINGES AT FIRE DOOR AT FIRE STAIRS ( B ) AT PUBLIC HALL, 1st STORY, SECTION AT SOUTH | Feb 6, 2023 |
| Jan 23, 2023 | C | Apt 1B · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 4th APARTMENT FROM WEST AT NORTH , SECTION AT SOUTH | Jan 29, 2023 |
| Nov 29, 2021 | A | Apt 5M · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''A-M'', AT EAST | Mar 4, 2022 |
| Nov 29, 2021 | B | Apt 5M · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL. IN THE BATHROOM LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''A-M'', AT EAST | Jan 3, 2022 |
| Nov 29, 2021 | A | Apt 5M · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE AT NORTH WALL. IN THE BATHROOM LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''A-M'', AT EAST | Mar 4, 2022 |
| Nov 29, 2021 | B | Apt 5M · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET .. IN THE BATHROOM LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''A-M'', AT EAST | Jan 3, 2022 |
| Nov 29, 2021 | B | Apt 5M · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL AND BUZZER IN THE ENTRANCE LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''A-M'', AT EAST | Jan 3, 2022 |
| Nov 29, 2021 | A | Apt 5M · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING. IN THE 1st ROOM FROM EAST LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''A-M'', AT EAST | Mar 4, 2022 |
| Nov 29, 2021 | A | Apt 5M · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL. IN THE 1st ROOM FROM EAST LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''A-M'', AT EAST | Mar 4, 2022 |
| Nov 29, 2021 | A | Apt 5M · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING. IN THE KITCHEN LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''A-M'', AT EAST | Mar 4, 2022 |
| Nov 29, 2021 | A | Apt 5M · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND WEST WALL. IN THE KITCHEN LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''A-M'', AT EAST | Mar 4, 2022 |
| Sep 29, 2021 | B | Apt 5M · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 3, 2021 |
| Sep 29, 2021 | B | Apt 5M · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 3, 2021 |
| Sep 29, 2021 | B | Apt 5M · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 3, 2021 |
| Sep 29, 2021 | B | Apt 5M · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 3, 2021 |
| Sep 29, 2021 | B | Apt 5M · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 3, 2021 |
| Sep 29, 2021 | B | Apt 5M · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5M, 5th STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 3, 2021 |
| Aug 27, 2021 | B | Apt 6V · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). IN THE ENTIRE APARTMENT LOCATED AT APT 6V, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 1, 2021 |
| Aug 27, 2021 | B | Apt 6V · § 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6V, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 1, 2021 |
| Aug 27, 2021 | B | Apt 6V · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSE ELECTRICAL OUTLET AT SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6V, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 1, 2021 |
| Aug 19, 2021 | B | Apt 6V · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF BEDBUGS IN THE ENTIRE APARTMENT LOCATED AT APT 6V, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 23, 2021 |
| Aug 19, 2021 | B | Apt 6V · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE THE LOCK ASSEMBLY AT DOOR IN THE ENTRANCE LOCATED AT APT 6V, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 23, 2021 |
| Aug 19, 2021 | C | Apt 6V · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6V, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 14, 2021 |
| Aug 19, 2021 | A | Apt 6V · § 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT 6V, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 22, 2021 |
| Apr 6, 2015 | A | SECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD., 1st STORY | Jul 10, 2015 |
| Sep 24, 2014 | B | Apt 6V · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTER COMMUNCATION SYSTEM IN THE ENTIRE APARTMENT LOCATED AT APT 6V, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 29, 2014 |
| Mar 24, 2014 | B | Apt 3B · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WALLS IN THE KITCHEN LOCATED AT APT 3B, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH | Apr 28, 2014 |
| Mar 24, 2014 | B | Apt 3B · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE AT WALLS IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH | Apr 28, 2014 |
| Mar 24, 2014 | B | Apt 3B · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL UNDER SINK IN THE KITCHEN LOCATED AT APT 3B, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH | Apr 28, 2014 |
| Mar 24, 2014 | B | Apt 3B · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH | Apr 28, 2014 |
| Mar 24, 2014 | B | Apt 3B · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH | Apr 28, 2014 |
| Oct 15, 2013 | B | Apt 3B · SECTION 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... CEILING & WEST WALL IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 19, 2013 |
| Oct 15, 2013 | B | Apt 3B · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS WASH BASIN IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 19, 2013 |
| Oct 15, 2013 | B | Apt 3B · SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION LOCKNUT AT WASTE LINE, WASH BASIN IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH | Nov 19, 2013 |
| Oct 15, 2013 | B | Apt 3B · SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION LOCKNUT AT SINK WASTELINE IN THE KITCHENETTE LOCATED AT APT 3B, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH | Nov 19, 2013 |
| Oct 15, 2013 | B | Apt 3B · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC WALL OUTLET IN THE KITCHENETTE LOCATED AT APT 3B, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH | Nov 19, 2013 |
| Oct 15, 2013 | B | Apt 3B · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE REFRIGERATOR DOOR GASKET IN THE KITCHENETTE LOCATED AT APT 3B, 3rd STORY, 5th APARTMENT FROM WEST AT NORTH | Nov 19, 2013 |
| Oct 15, 2013 | B | Apt 3B · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING & WEST WALL IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH | Nov 19, 2013 |
| Oct 15, 2013 | A | Apt 3B · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS, CEILING & TRIM THROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH | Jan 18, 2014 |
| Sep 9, 2013 | B | Apt 4D · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 14, 2013 |
| Sep 9, 2013 | B | Apt 4D · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND WALLS IN THE BATHROOM LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 14, 2013 |
| Sep 9, 2013 | B | Apt 4D · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE KITCHEN LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 14, 2013 |
| Mar 15, 2012 | B | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EVIDENCE OF WATER LEAK AT CEILING AT PUBLIC HALL (LOBBY) AT CELLAR | Apr 19, 2012 |
| Mar 15, 2012 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDED PLASTER CEILING AND WALLS AT PUBLIC HALL (LOBBY) AT CELLAR | Apr 19, 2012 |
| Mar 15, 2012 | A | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING AT PUBLIC HALL (LOBBY) AT CELLAR | Jun 18, 2012 |
| Feb 23, 2011 | B | Apt 1T · SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE PADLOCKED GATES IN THE ENTIRE APARTMENT LOCATED AT APT 1T, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | Mar 30, 2011 |
| Feb 23, 2011 | A | Apt 1T · SECTION 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION RADIATOR IN THE 6th ROOM FROM EAST LOCATED AT APT 1T, 1st STORY, 2nd APARTMENT FROM SOUTH AT WEST | May 29, 2011 |
| Jul 12, 2010 | B | Apt 6V · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 6V, 6th STORY | Aug 16, 2010 |
| Jul 12, 2010 | B | Apt 6V · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 6V, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 16, 2010 |
| Jul 12, 2010 | B | Apt 6V · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 6V, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 16, 2010 |
| Jul 12, 2010 | B | Apt 6V · SECTION 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 6V, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Aug 16, 2010 |
| Nov 6, 2009 | B | Apt 6H · SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6H, 6th STORY, 5th APARTMENT FROM EAST AT SOUTH , SECTION AT SOUTH | Dec 11, 2009 |
Showing 60 of 138. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 7:21 AM ET. BBL 4051800015.