18 floors · 273,898 sq ft · built 2013 · class H9 · owner of record: X & Y Development Group, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 273,898 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 183 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 183 days | Annual filing |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page | Feb 21, 2029 in 845 days | Filing window not open yet |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1158 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5181). Agency page | Dec 31, 2031 in 1888 days | Next due 2031 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 5, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. DURING INSPECTION, IT WAS OBSERVED THAT THERE ARE SEVERAL CURTAIN WALL PANELS THAT ARE CRACKED AT EXPOSURE 1 AND 4 OF THE FACADE, REPAIR AND/REPLACE #39166645K | Jan 20, 2026 DEFAULT | $12,500 |
| Apr 29, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN THE FACADE OF THE BUILDING. AT TIME OF INSPECTION, IT WAS OBSERVED THAT THERE ARE SEVERAL CURTAIN WALL PANELS THAT ARE CRACKED AT EXPOSURE 1 AND 4 OF THE FACADE., REPAIR AND/REPLACE #39146424Z | Aug 19, 2025 PENDING | $2,500 |
| Nov 8, 2024 | Unknown CLASS - 2 3301.2 HOLES IN FLOOR. AT TIME OF INSPECTION I OBSERVED HOLES GREATER THEN 2 INCHES COVERED BY 2 PLANKS THROUGHOUT JOBSITE HOLES WERE APPROX. 5X5 AND NOT PROPERLY COVERED.;CREATING A HAZARD FOR WORKERS AND PERS #39534284K | Mar 5, 2026 DEFAULT | $10,000 |
| Nov 8, 2024 | Construction CLASS - 1 AT TIME OF INSPECTION ON OF A 18 STORY BUILDING WITH A STOP WORK ORDER , I OBSERVED # 3FLAMMABLE OXYGEN TANKS UN STORED PROPERLY AS PER FDNY AT 1ST FLOOR LEVEL, IMPROPER STORAGE OF COMBUSTIBLE MATERIALS COULD #39534286Y | Mar 5, 2026 DEFAULT | $12,500 |
| Nov 8, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. A TIME OF INSPECTION I OBSERVED THAT STANDPIPE SYSTEM IS NOT PRESSURIZED. STANDPIPE SYSTEM MUST BE PRESSURIZED AS PER 3303.7.7.2 OF NYC BC, REPAIR AND/REPL #39129860K | Mar 5, 2026 DEFAULT | $6,250 |
| Nov 8, 2024 | Unknown CLASS - 2 3303.2.3.1TEMPORARY LIGHTING FOR CONSTRUCTION SITES.NOTICED 18 STORY BUILDING WITH STOP WORK ORDER .AT VARIOUS LOCATION I OBSERVED NO CONSTRUCTION LIGHTING CREATING DARK PASSAGEWAY AND DARK STAIRCASE. THIS CR #39534285M | Mar 5, 2026 DEFAULT | $10,000 |
| Oct 1, 2024 | Construction CLASS - 1 FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMENTING THE CONDITIONS OF PSID#Q0003116 BY THE AUGUST 1,2024 DEADLINE.TO DATE,THE DEPARTMENT HAS #37030648K | Sep 23, 2025 DEFAULT | $12,500 |
| Jun 21, 2022 | Plumbing CLASS - 1 FAILURE TO PROVIDE AIR PRESSURIZED ALARM SYSTEM FOR STANDPIPE SYSTEM DURING CONSTRUCTION AND DEMOLITION OPERATION. AT TIME OF INSPECTION I OBSERVED STANDPIPE SYSTEM NOT PRESSURIZED., PROVIDE STANDPIPE OR AIR PR #39064467J | Sep 6, 2022 DEFAULT | $12,500 |
| Jan 13, 2022 | Construction CLASS - 2 SEC. AC 27-1009(2) FAILURE TO SAFEGUARD PUBLIC AFFECTED BY CONSTRUCTION OPERATIONS. I OBSERVED PERIMETER FENCE AT EXP#3 HAD A 4X6' OPENING ALLOWING UNOBSTRUCTED ACCESS FROM TENANTS OF THE NEIGHBORING BLDG TO AC #35636723P | Oct 25, 2022 DEFAULT | $10,000 |
| Jan 13, 2022 | Construction CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTIE OF A STOP WORK ORDER(SWO). I OBSERVED SEVERAL WORKERS UNLOADING MATERIALS FROM A CONTAINER ON THE ROADWAY INTO THE CONSTRUCTION SITE. WORKERS HAD TO CROSS AN ACTIVE SIDE #35636722N | Oct 25, 2022 DEFAULT | $25,000 |
| Nov 12, 2021 | Construction CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER.AT TIMEOF INSPECTION ON AN ACTIVE 18 STORY NEW BUILDING CONSTRUCTION SITE.NOTICE ACTIVE CONSTRUCTION WORK BY A WORKER ON THE UPPER FLOOR OF THE BUI #35632824X | Mar 8, 2022 DEFAULT | $12,500 |
| Oct 25, 2021 | Site Safety CLASS - 1 FAILURE TO COMPLY WITH A COMMISSIONER'S ORDER(COMMISSIONER'S ORDER MANDATING SCO)AT TIME OF INSPECTION ON AN ACTIVE 18 STORY NEW BUILDING CONSTRUCTION SITE,NOTICE ACTIVE WORK ONSITE.ALSO OBSERVED THAT THE CONTR #35633002L | Jul 25, 2022 DEFAULT | $25,000 |
| Oct 25, 2021 | Construction CLASS - 2 PERMIT HOLDER FAILED TO PROVIDE ACCESS OR EXPOSE CONSTRUCTION WORK ON ACTIVE SITE. AT TIME OF INSPECTION ON AN ACTIVE 18 STY NO CONSTRUCTIONSITE NOTICE AN INDIVIDUAL ON SITE,WHEN I CALLED OUT STATING MY NAME & #35632813K | Dec 12, 2023 DEFAULT | $10,000 |
| Oct 25, 2021 | Construction CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER. FOR COMPLAINT#4812664. AT TIME OF INSPECTION ON AN ACTIVE 18 STY NB CONSTRUCTION SITE NOTICE 2 INDIVIDUALS ON SITE ONE AT EXP#1 ON 2 PHONE THE OTH #35632812Z | Dec 12, 2023 DEFAULT | $25,000 |
| Oct 12, 2021 | Construction CLASS - 2 FAILURE OF PERMIT HOLDER TO PROVIDE INSPECTION ACCESS TO AND/OR EXPOSEONGOING CONSTRUCTION OR WORK ON AN ACTIVE AND PERMITTED WORK SITE.AT TIME OF INSPECTION AT A 18 STORY NEW BUILDING,OBSERVED THAT JOBSITE IS #35632854R | Oct 25, 2022 DEFAULT | $10,000 |
| Sep 13, 2021 | Construction CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF STOP WORK ORDER. AT TIME OF INSPECTION ON AN ACTIVE PERMIT 18 STY NEW BLDG W/1 PARTIAL STOP WORK ORDER COMPLAINT#4738045 2 FULL STOP WORK ORDER COMPLAINT#4812664/#48 #35582781M | Feb 1, 2022 DEFAULT | $25,000 |
| Sep 1, 2021 | Construction CLASS - 1 WORK W/O PERMIT ATOI ON ACTIVE 18STYNB CONST SITE.NOTICE MINI CRANE ON1FL BACK OF BLDG OVERHANGING DRIVEWAY DOWN TO GARAGE INSIDE BLDG WHEN REQUEST WAS MADE FOR PERMIT FOR THIS CRANE ALONG W/DRAWINGS,LOADS IMPO #35589800K | Oct 25, 2022 DEFAULT | $12,500 |
| Sep 1, 2021 | Site Safety CLASS - 1 FAILURE TO MAINTAIN/DISPLAY ONSITE DOCS ATOI ON ACTIVE 18STYNB CONST SITE WHEN REQUEST WAS MADE FOR ALL APPROVE DOCS THAT AS PER CODE REQUIRED TO REMAIN ONSITE REQUESTED DOCS WERENT PROVIDED (1)APPROVE CONST DR #35582948P | Oct 25, 2022 DEFAULT | $12,500 |
| Sep 1, 2021 | Construction CLASS - 1 AC28-111.1 NO TEMP C/O-TCO/TEMP USE PERMIT (MODEL APT/SALES OFFICE) ATOI ON ACTIVE 18STYNB CONST SITE NOTICE ON 3&4FL OF CONST SITE 2MODEL APT THAT WHEN REQUEST WAS MADE FOR TCO FOR TEMP USE PERMIT/TCO COULDNT #35589801M | Oct 25, 2022 DEFAULT | $12,500 |
| Sep 1, 2021 | Construction CLASS - 1 FAILURE TO PROVIDE SAFETY EQUIPMENT OR INFORM WORKERS OF DANGER AFFECTED BY CONST OPS-FAILURE TO PROVIDE FALL PROTECTION.ATOI ON ACTIVE 18STYNB CONST SITE.NOTICE EXTENSIVE AMY OF OPENINGS UNPROTECTED&W/O FALL P #35582949R | Oct 25, 2022 DEFAULT | $25,000 |
| Sep 1, 2021 | Construction CLASS - 2 BC3314.4.8 FAILURE TO MAINTAIN PIPE SCF AS PER CODE ATOI ON ACTIVE 18STYNB CONST SITE NOTICE PIPE SCF THAT CONTRACTOR WORKERS FAILED TO MAINTAIN AS PER CODE SCF WAS ON 17&18FL SCF HALL (1)INADEQUATE PLANKING,(2 #35589802Y | Oct 25, 2022 DEFAULT | $6,250 |
| Sep 1, 2021 | Construction CLASS - 1 UNLAWFULLY CONTD WORK WHILE ON NOTICE OF SWO.ATOI ON ACTIVE 18STYNB CONST SITE,NOTICE@EXP3 OF CONST WALKWAY THAT ONCE WAS OPEN SIDE OF EXCAVATION THAT INSTRUCTION WAS GIVEN TO CONTRACTOR W/V INSTRUCTING NO FURT #35582947N | Oct 25, 2022 DEFAULT | $25,000 |
| Mar 4, 2021 | Plumbing CLASS - 2 EMERGENCY VENT NOT PIPED CORRECTLY MUST BE COMBINED AND TERMINATE OUTDOORS MC 1305.8 CONSTRUCTION DOCUMENTS SHALL SHOW CORRECT OIL LINE SIZING FGC 106.7 PORTABLE FIRE EXTINGUISHER SHALL BE PROVIDED MC 1301.8 OW #39037192X | Jun 8, 2021 DEFAULT | $6,250 |
| Feb 26, 2019 | Construction CLASS - 1 FAILURE TO INSTITUTE /MAINTAIN SAFETY EQUIPMENT MEASURES.(NO GUARDRAILS) AT THE TIME OF INSPECTION ON AN ACTIVE 18 STORY BUILDING OBSERVED ON THE 2ND FLOOR SKY LIGHTS MADE OF ALL GLASS WITH NO GUARDRAILS #35382818K | Sep 10, 2019 IN VIOLATION | $2,500 |
| Feb 26, 2019 | Construction CLASS - 1 FAILURE TO HAVE SITE SAFETY MANAGER PRESENT AS REQUIRED . AT THE TIME OF INSPECTION ON AN ACTIVE 18 STORY BUILDING WHEN SITE SAFETY MANAGER WAS REQUESTED BY INSPECTOR AT TIME OF INSPECTION NO ON ON THE JOB WAS #35382817Z | Sep 10, 2019 IN VIOLATION | $10,000 |
| Feb 26, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING . AT THE TIME OF INSPECTION ON AN ACTIVE 18 STORY BUILDING OBSERVED POOR HOUSEKEEPING THROUGHOUT THE CONSTRUCTION SITE,GARBAGE DEBRIS ON FLOORS 1 AND 2 YARD AT CELLAR #35382819M | Sep 10, 2019 IN VIOLATION | $2,500 |
| Feb 14, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. @ TIME OF INSP ON AN ACTIVE CONST. SITE NOTICED GARBAGE/DEBRIS THROUGHOUT THE FLOORS OF THIS 18 STORY BLDG WHEN CONST. DEBRIS/GARBAGE IS UNCHE #35421362K | Feb 18, 2020 IN VIOLATION | $2,500 |
| Feb 14, 2019 | Construction CLASS - 1 FAILURE TO HAVE SITE SAFETY MANAGER PRESENT AS REQUIRED. @ TIME OF INSP. ON AN ACTIVE 18 STORY BLDG WHEN SITE SAFETY MANAGER WAS REQUESTED BY INSPECTOR @ TIME OF INSP. NO ONE ON SITE WAS ABLE TO LOCATE DESIGNAT #35421360R | Feb 13, 2020 IN VIOLATION | $10,000 |
| Feb 14, 2019 | Construction CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMP. CONST. NO GUARDRAILS. @ TIME OF INSP ON AN ACTIVE CONST SITE NOTICED MAJOR HOLES/OPENINGS THROUGHOUT THE CONST. SITE W/O GUARDRAILS & ADEQUATE NE #35421361Z | Feb 11, 2020 IN VIOLATION | $2,500 |
| Feb 14, 2019 | Construction CLASS - 1 FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONST. OPERATIONS. @ TIME OF INSP ON AN ACTIVE CONST. SITE NOTICE THE JOBSITE CONCRETE FLOOR @ VARIOUS LEVEL OF THE 18 STORY BLDG WITH LARGE HOLES UNCOVER #35421372Y | Feb 11, 2020 IN VIOLATION | $10,000 |
| Dec 6, 2018 | Construction CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY:GUARDRAILS;AT THE TIME OF MY INSPECTION OF A 18 STORY BUILDING CURRENTLY AT ROOF LEVEL WITH CONSTRUCTION OPERATIONS IN PROGRESS.I OBSERVED WORKERS WORKING AT ROOF LEVEL AT E #35380626R | Jun 11, 2019 IN VIOLATION | $2,500 |
| Dec 6, 2018 | Construction CLASS - 1 WORK DOES NOT CONFORM TO APPROVED DOCUMENTS AND OR AMENDMENT;AT TIME OF INSPECTION OF A 18 STORY BUILDING CURRENTLY AT ROOF LEVEL WITH CONSTRUCTION OPERATIONS IN PROGRESS.I OBSERVED THE HOIST HAD BEEN REMOVED F #35380627Z | Jun 11, 2019 IN VIOLATION | $1,250 |
| Aug 15, 2018 | Construction CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER. AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE. THE WORKERS WAS WORKING EXP#1 GROUND FLOOR CLOSE TO GATE,1ST FL & OTHERS LOCATIONS. STOP WORK ORDE #35345147X | Jun 11, 2019 IN VIOLATION | $5,000 |
| Jul 30, 2018 | Construction CLASS - 1 BC3303.12 ELEVATORS AND HOISTS DURING CONSTRUCTION OR DEMOLITION. AT THE TIME OF MY INSPECTION OF AN ACTIVE CONSTRUCTION SITE, I OBSERVED THAT THE HOIST WAS NOT IN READINESS AND THE ELEVATOR INSPECTION WAS EXPI #35345229J | Feb 7, 2019 IN VIOLATION | $2,500 |
| Jul 30, 2018 | Construction CLASS - 2 FAILURE TO PROVIDE APPROVED CONSTRUCTION. DOCUMENTS AT JOBSITE AT TIME OF INSPECTION OF AN ACTIVE JOBSITE, NOTED: LARGE CUT-OUTS IN CONCRETE FLOOR SLABS 1ST, 2ND, CELLAR AND SUB-CELLARS. UPON REQUEST FOR STRUCT #35345235X | Feb 7, 2019 IN VIOLATION | $500 |
| Jul 16, 2018 | Construction CLASS - 1 SEC. 3301.2 HOLES NOT COVERED AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE. HOLES ARE FOUND ON FLOORS 2,5,9,12,18 IN THE SLAB NOT COVER ASREQUIRED. PUTTING PERSONS AT RISK OF A TRIPPING HAZAROUS & PUTTING #35345129M | Feb 7, 2019 IN VIOLATION | $2,500 |
| Jul 16, 2018 | Construction CLASS - 1 SEC. 3308.5.3 CABLES AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE. THE CABLE SYSTEM PROVIDED FOR THE PERIMETER EDGE OF THE BLDG ON FLOORS,2,5,9,12,18,19(ROOF)ARE INADEQUATE & ARE LOOSE,HANGING & MISSING SOME #35345130J | Feb 7, 2019 IN VIOLATION | $2,500 |
| Jun 8, 2018 | Construction CLASS - 1 INADEQUATE GUARDRAILS & NETTING. AT TIME OF INSPECTION, OBSERVED CABLE SYSTEM WITH CABLES MISSING, CABLES NOT TAUT, SECURED IMPROPERLY WITH INADEQUATE NUMBER OF UBOLTS AND MISSING IN SEVERAL AREAS. THIS CONDIT #35327198R | Jun 11, 2019 IN VIOLATION | $5,000 |
| Jun 8, 2018 | Construction CLASS - 1 BC3301.7 FAILURE TO COMPLY WITH DESIGN DRAWINGS. AT TIME OF INSPECTION OBSERVED A CLEARANCE MORE THAN 2.5" BETWEEN HOIST CAGE AND LANDING PLATFORM AT SEVERAL FLOORS. THIS CLEARANCE DOES NOT CONFORM WITH DESIGN #35327153N | Jun 11, 2019 IN VIOLATION | $625 |
| Jun 8, 2018 | Construction CLASS - 1 FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED. AT TIME OF INSPECTION, OBSERVED BUILDING FACADE AT EXP #1 (FRONT) WAS NOT COMPLETED UP TO 5TH FLOOR AND LOCATED DIRECTLY NEXT TO WALKWAY. NO PROTECTION FOR PUBLI #35327197P | Jun 11, 2019 IN VIOLATION | $10,000 |
| Jun 8, 2018 | Construction CLASS - 1 BC3301.7 FAILURE TO PROVIDE DESIGN DRAWINGS. OBSERVED GUARD RAILS, SYSTEM ATTACHED TO RESHORES AT MOST FLOORS. WHEN ASKED FOR DESIGN DRAWING NONE WERE PROVIDED. ALSO, OBSERVED INSTALLATION WAS NOT TYPICAL AND A #35327199Z | Jun 11, 2019 IN VIOLATION | $625 |
| Jun 8, 2018 | Construction CLASS - 1 MANUFACTURER SPECIFICATIONS: ELECTRICAL CORDS AND TOOLS. AT TIME OF INSPECTION, OBSERVED ELECTRICAL TOOL BEING USED WHILE HAVING A DEFECTIVE ELECTRICAL CORD. ALSO, OBSERVED SEVERAL ELECTRICAL CORDS IN USE WITH #35327152L | Feb 12, 2019 IN VIOLATION | $2,500 |
| Jan 27, 2017 | Construction CLASS - 1 FAILURE TO SAFEGUARD. NOTED: WORKER STEPPED ON HOLE COVER ON 18TH FLR WHILE CURTAIN WALL INSTALLATION IN PROGRESS, HOLE COVER GAVE IN UNDER WORKER'S WEIGHT, FELL ABOUT 20-25FT DOWN TO FLR BELOW. SWO ISSUED PURS #35217324L | Feb 12, 2019 IN VIOLATION | $25,000 |
| Jan 27, 2017 | Construction CLASS - 1 HOUSEKEEPING. NOTED: ACTIVE CONSTRUCTION SITE INSTALLATION OF CURTAIN WALL IN PROGRESS 18TH FLR. LOOSE DEBRI OBSERVED IN AREAS WHERE CURTAIN WALL NOT INSTALLED YET, PASSED GUARDRAIL SYSTEM, BY THE EDGE. (THROUG #35206475P | Feb 12, 2019 IN VIOLATION | $2,400 |
| Jan 27, 2017 | Construction CLASS - 1 SEC: BC3313.1. COMPRESSED GAS- NOT STORED PROPERLY. NOTED: WELDING EQUIPMENT STORED IN SUB CELLAR ALONG W/ ACETYLENE- COVERED W/ BLANKET TO KEEP HIDDEN. REM: COMPLY W/ CODE. #35206479M | Feb 12, 2019 IN VIOLATION | $1,600 |
| Jan 27, 2017 | Construction CLASS - 1 NO GUARDRAILS/INADEQUATE GUARDRAILS SYSTEM. NOTED: ACTIVE CONSTRUCTION SITE, TOPPED OFF NOT FULLY ENCLOSED. INADEQUATE GUARDRAILS OBSERVED WHERE MIDDLE CABLE LOOSE/MISSING & TOP CABLE LOOSE (NOT TAUT), ALSO ON #35206478K | Feb 12, 2019 IN VIOLATION | $1,200 |
| Jan 27, 2017 | Construction CLASS - 1 SEC: BC3308.3. VERTICAL NETTING NOT MAINTAINED. NOTED: ACTIVE CONSTRUCTIVE SITE, TOPPED OFF NOT FULLY ENCLOSED. VERTICAL NETTING NOT MAINTAINED IN AREAS WHERE CURTAIN WALL IS NOT UP YET (THROUGHOUT THE BLDG, VA #35206480J | Feb 12, 2019 IN VIOLATION | $1,600 |
| Jan 27, 2017 | Construction CLASS - 1 NO TOES BOARDS/ INADEQUATE ZERO CABLE. NOTED: ACTIVE SITE, BLDG TOPPED OFF NOT FULLY ENCLOSED INADEQUATE ZERO CABLE OBSERVED IN AREAS WHERE CURTAIN WALL NOT INSTALLED (ZERO CABLES NOT ON THE GROUND OR LOOSE ALL #35206477Z | Feb 12, 2019 IN VIOLATION | $1,000 |
| Jan 27, 2017 | Construction CLASS - 1 SEC: BC3303.4.5.1. MATERIAL @ THE EDGE OF THE BLDG WHEN NOT BEING USED W/IN 10 FT FROM PERIMETER. NOTED: ACTIVE ACONSTRUCTION SITE BLDG TOPPED OFF MATERIAL/DEBRIS NEXT TO PERIMETER ON FLRS 17,16,13,15. VERTICAL #35206476R | Feb 12, 2019 IN VIOLATION | $1,600 |
| Issued | Violation | Status |
|---|---|---|
| Jan 22, 2025 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00315 | DOB VIOLATION - ACTIVE |
| Jan 8, 2025 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00294 | DOB VIOLATION - ACTIVE |
| Jan 8, 2025 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00293 | DOB VIOLATION - ACTIVE |
| Jun 23, 2024 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023) #00180 | DOB VIOLATION - ACTIVE |
| Apr 22, 2023 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022) #01092 | DOB VIOLATION - ACTIVE |
| Aug 21, 2022 | FAILURE TO SUBMIT EER FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2021 #10437 | DOB VIOLATION - ACTIVE |
| Apr 13, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00288 | DOB VIOLATION - ACTIVE |
| Feb 2, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00425 | DOB VIOLATION - ACTIVE |
| Jan 19, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00537 | DOB VIOLATION - ACTIVE |
| Dec 22, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00965 | DOB VIOLATION - ACTIVE |
| Nov 24, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00594 | DOB VIOLATION - ACTIVE |
| Nov 24, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00595 | DOB VIOLATION - ACTIVE |
| Nov 24, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00593 | DOB VIOLATION - ACTIVE |
| Nov 24, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00592 | DOB VIOLATION - ACTIVE |
| Nov 24, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00591 | DOB VIOLATION - ACTIVE |
| Aug 7, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00764 | DOB VIOLATION - ACTIVE |
| May 29, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00803 | DOB VIOLATION - ACTIVE |
| May 4, 2016 | CONSTRUCTION #EX0701GG | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 8, 2025 | GHG Emissions - LL97 FTF-EN-LL97320 | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 7) | Active |
| Jan 22, 2025 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 8, 2025 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 8, 2025 | AEUHAZ FTC-AEU-HAZ | Active |
| Jun 23, 2024 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Apr 22, 2023 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Aug 21, 2022 | Retro-Commissioning - LL87 FTF-EN-EARCX | Active |
| Apr 13, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 2, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 19, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 22, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 24, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 24, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 24, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 24, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 24, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Aug 7, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| May 29, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
None open.