6 floors · 85,176 sq ft · built 1925 · class G9 · owner of record: 177th Upper Broadway Holdings Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 85,176 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 191 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 191 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 435 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2035) Likely applies Local Law 87 · Calendar year 2035 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2145). Agency page | Dec 31, 2035 in 3357 days | Next due 2035 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 15, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION OBSERVED SPALLED /CRACKED CONCRETE AT CELLAR AND 1ST FLOOR LEVEL ALSO VIOLATION #35717621Z ISSUED ON 10-18-2025 FOR FAILURE TO MAINTAIN - PARKING STRUCTURE., COMPLY WITH CODE. #39204134N | Nov 19, 2026 PENDING | $6,250 |
| Apr 20, 2026 | Construction CLASS - 2 NOTE AT THE TIME FOR REINSPECTION FOR CLASS 1 SUMMONS ENDING IN #0846N I OBSERVED SITE CLOSED AND NO CERTIFICATE OF CORRECTION FILED UPON REVIEWING THE DEPARTMENT RECORDS. COMPLY WITH CODE #39553219H | Dec 21, 2026 | $1,250 |
| Feb 24, 2026 | Construction CLASS - 2 PROJECT INFORMATION PANEL/SIDEWALK SHED PARAPET PANEL/CONSTRUCTION SIGN NOT PROVIDED OR NOT IN COMPLIANCE WITH SECTION DURING INSPECTION OF A SIDEWALK SHED IN PLACE, I OBSERVED THAT THERE WAS NO INFO PANEL AFFI #39550852J | Dec 21, 2026 | $300 |
| Feb 24, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION, SUPPORTED SCAFFOLD INSTALLED ALONG MULTIPLE ELEVATIONS WAS OBSERVED WITH LOOSE, SAGGING,&INADEQUATELY SECURED DEBRIS NETTING THROUGHOUT. NETTING WAS TORN &NOT PROPERLY FASTENED TO THE FRA #39550846N | Dec 21, 2026 | $5,000 |
| Feb 24, 2026 | Unknown CLASS - 2 MISCELLANEOUS VIOLATIONS. 3307.6.4.4 VERTICAL MEMBERS AND BEAMS: I OBSERVED AT EXPOSURE #1&2 SEVERAL VERTICAL POLES HAD NO HIGH VISIBILITY AFFIXED. THE VERTICAL MEMBERS NEAREST VEHICULAR ACCESS POINT SHALL BE P #39550851H | Dec 21, 2026 PENDING | $2,500 |
| Feb 24, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, IT WAS OBSERVED THAT CONTRACTOR FAILED TO POST REQUIRED WORK PERMIT IN A CONSPICUOUS PLACE AT THE SITE. NO WORK PERMITS WERE VISIBLY DISPLAYED FOR ONGOING CONSTRUCTION WORK. FAILURE TO PO #39550853L | Dec 21, 2026 PENDING | $2,500 |
| Oct 18, 2025 | Unknown CLASS - 1 FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION.AS NOTED:AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 5 LEVELS ABOVE GROUND LEVEL AND CELLAR,OBSERVED SPALLED/CRACKED CONCRETE AT #35717621Z | Dec 29, 2026 DEFAULT | $12,500 |
| Apr 11, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER DUE TO MISSING MORTAR JOINTS IN MULTIPLE AREAS THROUGHOUT EXPOSURES 1&2. STEP CRACKS WITH BULGING CONDITIONS AND DETERIORATION OF BRICKS AT THE CORNERS OF T #39144693H | Feb 5, 2026 IN VIOLATION | $2,500 |
| Apr 5, 2025 | Unknown CLASS - 1 FAILURE TO MAINTAIN PARKING STRUCTURE. NOTE: AT TIME OF INSPECTION ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 6 LEVELS(1 BELOW GL, 5 ABOVE GL) I OBSERVED (1)CRACKED/SPALLING CONCRETE WITH EXPOSED STEEL REIN #35716930H | Dec 8, 2025 IN VIOLATION | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Apr 11, 2025 | CONSTRUCTION REQUESTING ENGINEERING REPORT DUE TO MULTIPLE STEP CRACKS WITH BULGING CONDITIONS THROUGHOUT EXP 1&2. MORTAR JOINTS MISSING AT MULTIPLE AREAS AT EXP 1&2, ALSO THE DETERIORATION OF BRICKS. #25-00609 | DOB VIOLATION - ACTIVE |
| Apr 5, 2025 | CONSTRUCTION EWO PARKING STRUCT CONSIST OF 6 LVL.OBSERVED CRACKIG/SPALLIGCONCRETE SLAB, CONCRETE @ BEAMS, CONCRETE COLUMN & CRACKED/SPALLIG BRICK/FIRE PROOFING AS WELL AS EXPOSED/RUSTED REINFORCMNT @ MULTI LOCAT.REMDY:RET -AIN A NYS RDP TO DIRECT/SUPERV THE INSTALLN OF SAFTY MEAS @CELLAR,GL ,3-6 & PROVIDE SHORIN #FA1201DD | DOB VIOLATION - ACTIVE |
| Oct 19, 2005 | CONSTRUCTION #ZMTF01RNS | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Sep 23, 2026 | Parking Structures FTF-PS-INITL Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13 | Active |
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Sep 23, 2026 | DOB Safety | Parking Structures: Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13 | Open |
| Sep 15, 2026 | ECB | Unknown: AT TIME OF INSPECTION OBSERVED SPALLED /CRACKED CONCRETE AT CELLAR AND 1ST FLOOR LEVEL ALSO VIOLATION #35717621Z ISSUED ON 10-18-2025 FOR FAILURE TO MAINTAIN - PARKING STRUCTURE., COMPLY WITH CODE. | Open |
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |