5 floors · 56,145 sq ft · built 1920 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 47 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 56,145 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1568). Agency page | Dec 31, 2028 in 778 days | Next due 2028 |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-19 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 20, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: EMERGENCY LIGHYTS NOT WORKING AT: MAIN EXIT #1, EXIT #2, EXIT #3, EXIT #4, 3RDFLOOR HALLWAY AT ALL EXITS TO STAIRWAYS. 2ND FLOOR AT ALL EXITS TO STA #35729017K | Mar 18, 2026 POP/IN-VIO | $0 |
| Feb 20, 2026 | Construction CLASS - 2 REISSUE ECB #35691893J. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANTMANNER. NOTED: AT CELLAR LEVEL(BOILER ROOM, ELECTRIC METER ROOM) THEREARE SEVERAL STEEL BEAMS MISSING THE FIRE PROOF COATING. REMEDY: REPAIR #35729016Z | Mar 18, 2026 POP/IN-VIO | $0 |
| Mar 27, 2025 | Construction CLASS - 2 REISSUE: 35678951M-FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: AT CELLAR THERE ARE SEVERAL STEAL BEAM MISSING THE FIREPROOF COATING. REMEDY: COMLY WITH CODE. #35691893J | May 19, 2025 POP/IN-VIO | $0 |
| Mar 29, 2024 | Construction CLASS - 2 RE-ISSUE #35672906X-FAILURE TO MAINTAIN BUILDING IN CODE-COMLIANT MANNER. NOTED: OBSERVED AT BASEMENT LEVEL, NUMEROUS STRUCTED STEEL BEAMSARE MISSING THE FIREPROOF COATING AT VARIOUS LOCATIONS THAT ARE EXPOSING #35678951M | May 6, 2024 POP/IN-VIO | $0 |
| Mar 15, 2023 | Construction CLASS - 2 REISSUE #35643216X.FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:OBSERVED AT VARIOUS LOCATIONS THROUGHOUT BASEMENT LEVEL FIREPROOF COATING FROM STEEL BEAMS MISSING/FALLEN,EXPOSING STRUCTURAL STEEL MEMBE #35672906X | Jun 15, 2023 POP/IN-VIO | $0 |
| Mar 25, 2022 | Construction CLASS - 2 REISSUE#35553753M.FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT TIME OF INSPECTION I OBSERVED AT VARIOUS LOCATIONS THROUGHOUT THEBASEMENT LEVEL FIRE POST CONTAINING FROM STEEL BEAMS IS MISSING FALLEN #35643216X | Jul 14, 2022 POP/IN-VIO | $0 |
| Feb 19, 2021 | Construction CLASS - 2 FALIRE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED OBSERVED AT VARIOUS LOCATIONS THROUGHOUT BASMENET FIREPROOF COATNG FROM STEEL BEAMS IS MISSING.FALLEN ALSO IN GYM ROOM 301 AN APPROX 4FT X 8 FT SHEET #35553753M | May 20, 2021 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #01432 | DOB VIOLATION - ACTIVE |
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 13, 2026, 5:50 PM ET. BBL 1015680008.