2 floors · 2 apartments · 4,750 sq ft · built 1929 · class K4 · owner of record: Delerimar Rlty Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1162 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 9, 2023 | Construction CLASS - 2 I OBSERVED IN CELLAR OF STORE GAS METER ROOM NEWLY INSTALLED GAS PIPING AND FITTINGS. NO PERMITS ON FILE FOR ANY WORK PERFORMED. WORK WAS 100% COMPLETED AT TIME OF INSPECTION., OBTAIN ALL PERMITS #39081105R | Oct 7, 2024 IN VIOLATION | $0 |
| Nov 3, 2017 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS. NOTED: IN RECORD INDICATED FAILURE TO CERTIFY CORRECTION CLASS 1 VIOLATIONS #34874244P DATED: 11/ #35237269X | Mar 5, 2018 WRITTEN OFF | $0 |
| Nov 30, 2010 | Construction CLASS - 1 WORK W/O PERMIT.HAZARDOUS.OBSERVED IN THE CELLAR THE REMOVAL OF GAS FIRED BOILERS & REPLACED W/1 GAS FIRED BOILER,2 GAS FIRED WATER HEATERS.RESEARCHED DOB RECORDS & FOUND NO PERMITS ISSUED TO THIS WORK IN CELLA #34874244P | Sep 16, 2011 IN VIOLATION | $0 |
| Nov 30, 2010 | Plumbing CLASS - 1 FAILURE TO HAVE NEW PLUMBING OR ALTERED PLUMBING SYSTEM TESTED.HAZARDOUS.RESEARCHED DOB RECORDS & FOUND NO TESTS OR INSPECTION PERFORMED FOR THE BOILER REPLACEMENT OR WATER HEATER INSTALLATIONS.PERFORM TEST & I #34874245R | Sep 16, 2011 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 23, 2011 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00184 | DOB VIOLATION - ACTIVE |
| Feb 23, 2011 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00183 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 7) | Active |
| Feb 23, 2011 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 23, 2011 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 21, 2024 | B | Apt 2B · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 25, 2024 |
| Aug 21, 2024 | B | Apt 2B · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 25, 2024 |
| Aug 21, 2024 | B | Apt 2B · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 25, 2024 |
| Aug 21, 2024 | C | § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE AT ENTRANCE DOOR TO BUILDING AT PUBLIC HALL, 1st STORY | Aug 27, 2024 |
| Aug 21, 2024 | C | § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCKING DEVICE AT ENTRANCE DOOR TO BUILDING AT PUBLIC HALL | Aug 27, 2024 |
| Aug 21, 2024 | B | § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING COVER PLATE FOR ELECTRIC OUTLET AT EAST WALL AT PUBLIC HALL, 1st STORY | Sep 25, 2024 |
| Aug 21, 2024 | C | § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK DEVICE BUILDING ENTRANCE DOOR | Aug 27, 2024 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 8:02 AM ET. BBL 3007170046.