Brooklyn · Block 3278 · Lot 27 · 11237

412 Knickerbocker Avenue

3 floors · 2,500 sq ft · built 1931 · class K9 · owner of record: 412 Knickerbocker Realty Llc

3open violations
$9,550ECB/OATH penalties owed
0HPD class C (immediately hazardous)
69dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 69 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)

Open violations

ECB / OATH (5) · $9,550 owed
IssuedViolationHearingBalance
Sep 23, 2026Unknown CLASS - 2
WEATHERPROOF INTEGRITY OF ADJOINING BUILDINGS. AT TIME OF INSPECTION OBSERVED: BUILDING FULLY DEMOLISHED TO CELLAR LEVEL. NO WEATHERPROOF AT ADJOINING PROPERTY EXPO# 4 3RD FL. LEVEL OF 410 KNICKERBOCKER AVE. CO
#39559548X
Dec 2, 2026
PENDING
$2,500
Aug 6, 2026Construction CLASS - 2
I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1 CONTRARY TO CODE. MESH SIDEWALK SHED PARAPET NOT INSTALLED CONTRARY TO CODE 3307.6.4.6 PARAPET. VERTICAL MEMBERS PLACED WITHIN 18IN FROM THE FACE OF THE CURB CONT
#39557605Y
Oct 14, 2026
$2,400
Aug 6, 2026Construction CLASS - 2
UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1 NOT CONSTRUCTED OR MAINTAINED ACCORDING TO CODE. FENCE NOT MAINTAINED IN SOUND CONDITION. EXCESSIVE GRAFFITI ON FENCE (NOT FULLY PAINTED HUNTER GREEN). PR
#39557600P
Oct 14, 2026
PENDING
$1,000
Aug 6, 2026Construction CLASS - 2
UPON INSPECTION I OBSERVED PEDESTRIAN PROTECTION (JERSEY BARRIERS IN STREET) NOT MAINTAINED ACCORDING TO CODE 3307.8 MAINTAINING DEPARTMENT OF TRANSPORTATION PEDESTRIAN AND BICYCLIST PROTECTION IN PLACE. BARRIE
#39557603K
Oct 14, 2026
$2,400
Aug 6, 2026Construction CLASS - 2
UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1 WITH A INADEQUATE FENCE PROJECT INFO PANEL INSTALLED CONTRARY TO CODE. MISSING REQUIRED OWNER INFORMATION (CONTACT NUMBER) AND REQUIRED GC INFORMATION (CO
#39557601R
Oct 14, 2026
$1,250
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 4)
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 23, 2026ECBUnknown: WEATHERPROOF INTEGRITY OF ADJOINING BUILDINGS. AT TIME OF INSPECTION OBSERVED: BUILDING FULLY DEMOLISHED TO CELLAR LEVEL. NO WEATHERPROOF AT ADJOINING PROPERTY EXPO# 4 3RD FL. LEVEL OF 410 KNICKERBOCKER AVE. COOpen
Aug 6, 2026ECBConstruction: I OBSERVED A SIDEWALK SHED INSTALLED AT EXPOS 1 CONTRARY TO CODE. MESH SIDEWALK SHED PARAPET NOT INSTALLED CONTRARY TO CODE 3307.6.4.6 PARAPET. VERTICAL MEMBERS PLACED WITHIN 18IN FROM THE FACE OF THE CURB CONTClosed
Aug 6, 2026ECBConstruction: UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1 NOT CONSTRUCTED OR MAINTAINED ACCORDING TO CODE. FENCE NOT MAINTAINED IN SOUND CONDITION. EXCESSIVE GRAFFITI ON FENCE (NOT FULLY PAINTED HUNTER GREEN). PROpen
Aug 6, 2026ECBConstruction: UPON INSPECTION I OBSERVED PEDESTRIAN PROTECTION (JERSEY BARRIERS IN STREET) NOT MAINTAINED ACCORDING TO CODE 3307.8 MAINTAINING DEPARTMENT OF TRANSPORTATION PEDESTRIAN AND BICYCLIST PROTECTION IN PLACE. BARRIEClosed
Aug 6, 2026ECBConstruction: UPON INSPECTION I OBSERVED A FENCE INSTALLED AT EXPOS 1 WITH A INADEQUATE FENCE PROJECT INFO PANEL INSTALLED CONTRARY TO CODE. MISSING REQUIRED OWNER INFORMATION (CONTACT NUMBER) AND REQUIRED GC INFORMATION (COClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 6:20 AM ET. BBL 3032780027.

Look up another building