Brooklyn · Block 3290 · Lot 26 · 11237

412 Harman Street

3 floors · 6 apartments · 4,130 sq ft · built 1931 · class C2 · owner of record: Bologna, Mario

62open violations
$0ECB/OATH penalties owed
3HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-31 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (12)
IssuedViolationStatus
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
#25772
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#05928
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#27325
DOB VIOLATION - ACTIVE
Feb 24, 2017LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
#10512
DOB VIOLATION - ACTIVE
Oct 1, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
#09522
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#12010
DOB VIOLATION - ACTIVE
Mar 1, 2013LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
#09041
DOB VIOLATION - ACTIVE
Dec 13, 2011LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
#12058
DOB VIOLATION - ACTIVE
Dec 31, 2009LOW PRESSURE BOILER

#14072
DOB VIOLATION - ACTIVE
Jan 1, 2009LOCAL LAW 62/91 - BOILERS

#17813
DOB VIOLATION - ACTIVE
Jan 3, 2008LOCAL LAW 62/91 - BOILERS

#17793
DOB VIOLATION - ACTIVE
Jul 25, 1994LOCAL LAW 62/91 - BOILERS

#04400
DOB VIOLATION - ACTIVE
DOB NOW Safety (12)
IssuedViolationStatus
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Feb 24, 2017Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
Active
Oct 1, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
Mar 1, 2013Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
Active
Dec 13, 2011Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
Active
Dec 31, 2009Boiler LBLVIO
Active
Jan 1, 2009Boiler LL6291
Active
Jan 3, 2008Boiler LL6291
Active
Jul 25, 1994Boiler LL6291
Active
HPD (38) · C 3 · B 23 · A 12
IssuedClassViolationCorrect by
Jul 15, 2013AApt L1 · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM , THE 3rd ROOM FROM NORTH, THE 2nd ROOM FROM NORTH, THE KITCHEN LOCATED AT APT L1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOct 18, 2013
Jul 15, 2013BApt L1 · SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE LOCATED AT APT L1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTAug 19, 2013
Jul 15, 2013BApt L1 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE LOCATED AT APT L1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTAug 19, 2013
Jul 15, 2013BApt L1 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BALANCE AT LOWER SASH AT SOUTH TWO WINDOW IN THE KITCHEN LOCATED AT APT L1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTAug 19, 2013
Jul 15, 2013BApt L1 · SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION UNDER SINK IN THE KITCHEN LOCATED AT APT L1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTAug 19, 2013
Jul 15, 2013BApt L1 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITCHEN LOCATED AT APT L1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTAug 19, 2013
Jul 15, 2013BApt L1 · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT L1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTAug 19, 2013
Aug 18, 2008CApt 1R · SECTION 27-2056.7 ADM CODE -CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNERSep 13, 2008
Jun 12, 2008ASECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING.Sep 15, 2008
Jun 12, 2008BApt 3R · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 3 STY SOUTH APT 3R SANCHEZ. , SECTION '' ''Jul 17, 2008
Jun 12, 2008BApt 3R · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK 3 STY SOUTH APT 3R KITCHEN. , SECTION '' ''Jul 17, 2008
Jun 12, 2008BApt 3R · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE 3 STY SOUTH APT 3R. , SECTION '' ''Jul 17, 2008
Jun 12, 2008AApt 3R · SECTION 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO HEAVY DUTY LATCH SET HEAVY DUTY DEAD BOLT CHAIN DOOR GUARD 3 STY SOUTH APT 3R. , SECTION '' ''Sep 15, 2008
Jun 12, 2008CD26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUB HALL & ON BOILER ROOM DOOR.Jun 18, 2008
Jun 12, 2008BD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT PLASTER CLG CELLAR REAR.Jul 17, 2008
Jun 12, 2008AD26-19.07 ADM CODE INSTALL AND MAINTAIN SUFFICIENT LIGHT OR LIGHTS OF AT LEAST 40 WATTS INCANDESCENT OR EQUIVALENT EACH, TO LIGHT ADEQUATELY FROM SUNSET TO SUNRISE THE REAR YARD.Sep 15, 2008
Jun 12, 2008ASECTION 62 M/D LAW REARRANGE TELEVISION AND/OR RADIO ANTENNA TO BE AT LEAST 10 FEET ABOVE ROOF AND NOT ATTACHED TO ANY FIRE ESCAPE OR SOIL OR VENT LINE GOOSE NECK LADDER ROOF AT REAR.Sep 15, 2008
Jun 12, 2008AD26-20.08 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING.Sep 15, 2008
Jun 12, 2008CD26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCUTTLE COVER UNOPENABLE 3 STY PUB HALL TO ROOF ER1.Jun 18, 2008
Jun 12, 2008BD26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION 1 STORY PUBLIC HALL.Jul 17, 2008
Jul 28, 2006AApt 1R · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS THRU OUT 1 STY WEST APT 1R. , SECTION '' ''Nov 24, 2006
Jul 28, 2006AApt 1R · SECTION 27-2005 ADM CODE REFIT DOOR FRONT ENTRANCE 1 STY WEST APT 1R. , SECTION '' ''Nov 24, 2006
Jul 28, 2006AApt 1R · SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILINGS THRU OUT 1 STY WEST APT 1R. , SECTION '' ''Nov 24, 2006
Jul 28, 2006AApt 1R · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING VINYL TILES FLOORS KITCHEN & 1 ROOM FROM KITCHEN 1 STY WEST APT 1R. , SECTION '' ''Nov 24, 2006
Jul 28, 2006AApt 1R · SECTION 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO HEAVY DUTY LATCH SET DEAD BOLT & CHAIN DOOR GUARD ENTRANCE 1 STY WEST APT 1R , SECTION '' ''Nov 24, 2006
Jul 28, 2006AApt 1R · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE INTERIOR WOOD TRIM WINDOWS FRONT ROOM 1 STY WEST APT 1R. , SECTION '' ''Nov 24, 2006
May 18, 1999BSECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 200 WATTS MINIMUM REQUIRED FIXTURE PRESENT LIGHT NOT ONJul 5, 1999
Aug 6, 1996BApt 1R · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE OVEN RANGE DOOR KITCHEN 1 STY WEST APT 1R. , SECTION '' ''Sep 23, 1996
Aug 6, 1996BApt 1R · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE 1 STY WEST APT 1R. , SECTION '' ''Sep 23, 1996
Aug 6, 1996BApt 1R · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRES EXTENSION CORDS 2 ROOM FROM FRONT 1 STY WEST APT 1R. , SECTION '' ''Sep 23, 1996
Aug 6, 1996BApt 1R · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 1 STY WEST APT 1R BRERRIOS. , SECTION '' ''Sep 23, 1996
Aug 6, 1996BApt 1R · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CABINET UNDER SINK KITCHEN 1 STY WEST APT 1R. , SECTION '' ''Sep 23, 1996
Aug 6, 1996BApt 1R · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES & MICE THRU OUT 1 STY WEST APT 1R. , SECTION '' ''Sep 23, 1996
Jul 9, 1996BApt 1R · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FACING AROUND WEST WINDOW NORTH ROOM 1 STY WEST APT 1R. , SECTION '' ''Aug 26, 1996
Jul 9, 1996BApt 1R · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR KITCHEN 1 STY WEST APT 1R. , SECTION '' ''Aug 26, 1996
Jul 9, 1996BApt 1R · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE DOOR OVEN GAS RANGE KITCHEN 1 STY WEST APT 1R. , SECTION '' ''Aug 26, 1996
Jul 9, 1996BApt 1R · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES THRU OUT 1 STY WEST APT 1R. , SECTION '' ''Aug 26, 1996
Feb 26, 1991BApt 2L · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 2 STY EAST APT 2L METO. , SECTION '' ''Apr 15, 1991

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 5:11 PM ET. BBL 3032900026.

Look up another building