| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 43 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 43 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 59 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 179,213 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 164 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 164 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 287 days | Registered through 2027-09-01 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $96,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 826 days | Filing window not open yet |
| Energy audit and retro-commissioning (2033) Likely applies Local Law 87 · Calendar year 2033 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1363). Agency page | Dec 31, 2033 in 2600 days | Next due 2033 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | CONSTRUCTION EMERGENCY WORK ORDER.OBSRVD@EXP 3 1STFL,FACADE MASONRY WALL BLOWN OUT DUE TO IMPROPER CNCRTE PLCMNT@NEIGHBORNG CONSTRUCTN SITE 405E 1ST ST BRCK MASNRY FACADE WALL IS PRTLLY CLLPSD,BULGD,CRCKD,DELAMNTD.OWNR TO ENGAGE NYSPE&ENDRSD CNTRCTR TO IMMED TEMP STABILIZE THE CMPRMSD FACADE WALL.NYSPE TO SBMT M #FEU10601AK | DOB VIOLATION - ACTIVE |
| Oct 31, 2025 | CONSTRUCTION FAILURE TO MAINTAIN.OBSRVD@EXP3 1STFL FACADE MASONRY WALL BLOWN OUT DUE TO IMPROPER CNCRTE PLCMNT@NEIGHBORNG CONSTRUCTION SITE 405 E51 ST BRCK MASONRY FACADE WALL IS PRTLLY CLLPSD,BULGD,CRCKD&DLMNT.OWNR TO ENGAGE NYSPE&ENDRSD CNTRCTR TO EVAL THE ENT BLDG&RPAIR UNDR PRMT.FILE FOR PRMTS BY 12/1/25.SGN #FEU10602AK | DOB VIOLATION - ACTIVE |
| Feb 22, 2024 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 #01513 | DOB VIOLATION - ACTIVE |
| May 5, 1992 | CONSTRUCTION #B2MC06 | VIOLATION UNSERVED ECB-ACTIVE |
| Mar 28, 1989 | ELEVATOR (32)RENEW LININGS (43)ADJUST OR REPLACE #14553\4 | DOB VIOLATION - ACTIVE |
| Nov 14, 1988 | ELEVATOR #14556-3 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Feb 22, 2024 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 3, 2026 | B | § 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL. | Jul 8, 2026 |
| Oct 16, 2019 | B | Apt 12D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL APPRX 2 SQUARE FEET IN THE BATHROOM LOCATED AT APT 12D, 12th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH ORIGINAL VIOLATION 13103864 ISSUED 03-JUN-19 HAS BEEN UPGRADED TO CLASS B PER ADMI | Nov 20, 2019 |
| Jun 18, 2019 | B | Apt 12D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST WALL IN THE BATHTUB IN THE BATHROOM LOCATED AT APT 12D, 12th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH | Jul 23, 2019 |
| Jun 4, 2019 | B | Apt 12D · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WEST WALL IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 12D, 12th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH | Jul 9, 2019 |
| Jun 4, 2019 | B | Apt 12D · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WEST WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 12D, 12th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH | Jul 9, 2019 |
| May 29, 2019 | B | Apt 12D · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WEST WALL IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 12D, 12th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 3, 2019 |
| May 29, 2019 | B | Apt 12D · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE THE CERAMIC TOWEL BAR AT EAST WALL IN THE BATHROOM LOCATED AT APT 12D, 12th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 3, 2019 |
| May 29, 2019 | B | Apt 12D · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 12D, 12th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 3, 2019 |
| May 29, 2019 | B | Apt 12D · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH, EAST AND WEST WALLS IN THE 2nd ROOM FROM EAST LOCATED AT APT 12D, 12th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 3, 2019 |
| May 29, 2019 | B | Apt 12D · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 12D, 12th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 3, 2019 |
| May 23, 2019 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Aug 26, 2019 |
| May 23, 2019 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | Aug 26, 2019 |
| May 23, 2019 | A | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY | Aug 26, 2019 |
| May 23, 2019 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY | Aug 26, 2019 |
| May 23, 2019 | A | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX SIGN MISSING AT PUBLIC HALL, 1st STORY | Aug 26, 2019 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 18, 2026, 11:00 PM ET. BBL 1013630043.