Brooklyn · Block 1885 · Lot 10 · 11205

41 Franklin Avenue

32 apartments · 79,253 sq ft · built 2025 · class D1 · owner of record: Lot 15 Llc

7open violations
$42,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 65 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 65 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 81 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 79,253 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 186 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 186 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 796 days
Next cycle year 2028
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1885). Agency page

Dec 31, 2035
in 3352 days
Next due 2035

Open violations

ECB / OATH (13) · $42,500 owed
IssuedViolationHearingBalance
Sep 15, 2026Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. ASNOTED: AT THE TIME OF INSPECTION OF A 7 STORY NEW BULDING ACTIVELY DOING INTERIOR WORK AND EXTERIOR DIGGING. I OBSERVED LARGED AMOUNT OF CON
#35730255Y
Nov 25, 2026
PENDING
$2,500
Sep 15, 2026Construction CLASS - 1
FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO GUARD RAILS. AS NOTED: AT TIME OF INSPECTION OF AN ACTIVE JOBSITE OF A 7 STORY NEW BUILDING CURRENTLY AT THE BULKHEAD, I OBSE
#35730254M
Nov 25, 2026
PENDING
$5,000
Sep 1, 2026Construction CLASS - 1
UPON INSPECTION I OBSERVED INADEQUATE AND HAZARDOUS HOUSEKEEPING PRACTICES. LARGE PILES OF ACCUMULATED COMBUSTIBLE MATERIAL/TRASH INADEQUATELY STORED IN YARD & INTERIOR AT EXPOS 1, EGRESS COMPROMISED (FIRE HAZA
#39558656Z
Nov 18, 2026
PENDING
$2,500
Sep 1, 2026Construction CLASS - 2
UPON INSPECTION OF AN ACTIVE 7 STORY NB CONSTRUCTION SITE I OBSERVED NO "NO SMOKING" SIGNS POSTED AT THE SITE IN ACCORDANCE WITH THE PROVISIONS OF THE NEW YORK CITY FIRE CODE. NO SIGNS POSTED ON FENCE OR INTER
#39558660L
Nov 18, 2026
PENDING
$1,250
Sep 1, 2026Unknown CLASS - 1
UPON INSPECTION I OBSERVED PIPE SCAFFOLD INSTALLED AND IN USE AT EXPOS 1 IN A UNSAFE MANNER CONTRARY TO CODE 3314.1 . INADEQUATE AND UNSAFE FOOTINGS INSTALLED. NO STACKING PINS INSTALLED. MISSING GUARDRAILS AND
#39558648Z
Nov 18, 2026
PENDING
$5,000
Sep 1, 2026Unknown CLASS - 1
UPON INSPECTION I OBSERVED MISSING AND DEFECTIVE FIRE EXTINGUISHERS AT MULTIPLE LOCATIONS ON 1ST, 2ND, 3RD, 5TH FLOORS, ROOF, SETBACK EXPOS 3 & CELLAR. EXTINGUISHERS WERE NO LONGER CHARGED, MISSING, NOT PROPERL
#39558658M
Nov 18, 2026
PENDING
$1,250
Feb 18, 2026Construction CLASS - 2
SOME WINDOWS WERE INSTALLED WITH U-FACTOR 0.30 & 0.28 CONTRARY TO EN DRAWINGS AND ARCHITECTURAL DRAWINGS THAT INDICATE 0.25 & 0.26., CONFORMWORK TO APPROVED CONSTRUCTION DOCUMENTS/AMENDMENTS; PLEASE GO TO HTTP:
#39177635K
May 6, 2026
IN VIOLATION
$0
Feb 1, 2026Unknown CLASS - 2
7 STORY NB BUILDING FOOTPRINT 10319 SQ. FT. NO CONSTRUCTION ACTIVITY TAKIN PLACE AT THE TIME OF INSPECTION. I WALKED AROUND THE OUTSIDE OF THE BUILDING BANGED ON DOOR AND YELLED INTO THE SITE THROUGH THE GATE.
#39549777K
Dec 18, 2026
$2,500
Nov 3, 2025Unknown CLASS - 2
3308.6.1.4.2- OBSERVED ACTIVE JOBSITE AT ROOF LEVEL APPROX. 80 FT. NO HORIZONTAL NETTING OR ANY ALTERNATE SYSTEMS OF PROTECTION HAS BEEN PROVIDED, ONGOING STRIPPING TAKING PLACE 6TH & 7TH FLRS. REVIEW OF SITE S
#39546620Z
Jul 9, 2026
IN VIOLATION
$2,500
Oct 3, 2025Construction CLASS - 1
AT TIME OF INSPECTION KNUCKLE BOOM CRANE WAS ON SITE SERVICING THE JOB. THE OPERATOR OF THE USER'S KNUCKLE BOOM CRANE DID NOT HOLD A VALID NEW YORK CITY HMO LICENSE AT TIME OF INSPECTION. THE HMO LICENSE IS REQ
#39162440Z
Jan 19, 2027
$5,000
Oct 3, 2025Cranes and Derricks CLASS - 2
AT TIME OF INSPECTION, A KNUCKLE BOOM WAS ON SITE SERVICING THE JOB SITE W/O CERTIFICATE OF ON-SITE INSPECTION. THE KNUCKLE BOOM WAS WORKING OUTSIDE OF THE EXEMPTION OF BC 3319.10. A CERTIFICATE OF ON-SITE IS R
#39162520Z
Feb 1, 2027
$5,000
Oct 3, 2025Construction CLASS - 1
AT TIME OF INSPECTION, AT JOB SITE OPERATED BY THE GC A KNUCKLE BOOM CRANE WAS ON SITE SERVICING THE SITE WITHOUT A CERTIFICATE OF OPERATION. THE KNUCKLE BOOM CRANE WAS WORKING OUTSIDE OF THE EXEMPTION OF BC 33
#39162518J
Feb 1, 2027
$5,000
Oct 3, 2025Construction CLASS - 1
AT TIME OF INSPECTION KNUCKLE BOOM CRANE WAS ON SITE SERVICING THE JOB. THE OPERATOR OF THE USER'S KNUCKLE BOOM CRANE DID NOT HOLD A VALID NEW YORK CITY HMO LICENSE AT TIME OF INSPECTION. THE HMO LICENSE IS REQ
#39162519L
Feb 1, 2027
$5,000
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 15, 2026ECBConstruction: FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. ASNOTED: AT THE TIME OF INSPECTION OF A 7 STORY NEW BULDING ACTIVELY DOING INTERIOR WORK AND EXTERIOR DIGGING. I OBSERVED LARGED AMOUNT OF CONOpen
Sep 15, 2026ECBConstruction: FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO GUARD RAILS. AS NOTED: AT TIME OF INSPECTION OF AN ACTIVE JOBSITE OF A 7 STORY NEW BUILDING CURRENTLY AT THE BULKHEAD, I OBSEOpen
Sep 1, 2026ECBConstruction: UPON INSPECTION I OBSERVED INADEQUATE AND HAZARDOUS HOUSEKEEPING PRACTICES. LARGE PILES OF ACCUMULATED COMBUSTIBLE MATERIAL/TRASH INADEQUATELY STORED IN YARD & INTERIOR AT EXPOS 1, EGRESS COMPROMISED (FIRE HAZAOpen
Sep 1, 2026ECBConstruction: UPON INSPECTION OF AN ACTIVE 7 STORY NB CONSTRUCTION SITE I OBSERVED NO "NO SMOKING" SIGNS POSTED AT THE SITE IN ACCORDANCE WITH THE PROVISIONS OF THE NEW YORK CITY FIRE CODE. NO SIGNS POSTED ON FENCE OR INTEROpen
Sep 1, 2026ECBUnknown: UPON INSPECTION I OBSERVED PIPE SCAFFOLD INSTALLED AND IN USE AT EXPOS 1 IN A UNSAFE MANNER CONTRARY TO CODE 3314.1 . INADEQUATE AND UNSAFE FOOTINGS INSTALLED. NO STACKING PINS INSTALLED. MISSING GUARDRAILS ANDOpen
Sep 1, 2026ECBUnknown: UPON INSPECTION I OBSERVED MISSING AND DEFECTIVE FIRE EXTINGUISHERS AT MULTIPLE LOCATIONS ON 1ST, 2ND, 3RD, 5TH FLOORS, ROOF, SETBACK EXPOS 3 & CELLAR. EXTINGUISHERS WERE NO LONGER CHARGED, MISSING, NOT PROPERLOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 27, 2026, 12:56 PM ET. BBL 3018850010.