Manhattan · Block 1472 · Lot 44 · 10075

408 East 78 Street

4 floors · 17 apartments · 7,000 sq ft · built 1910 · class C5 · owner of record: Brusco Enterprises,Inc.

39open violations
$5,000ECB/OATH penalties owed
9HPD class C (immediately hazardous)
43dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 43 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 43 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 59 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 287 days
Registered through 2027-09-01
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-11 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (2) · $5,000 owed
IssuedViolationHearingBalance
Feb 17, 2026Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER. #061225PI10802HZ CONTROL #348065 DATED 06/12/25. NO COMPLIANCE ON FILE FOR ANNUAL PARAPET OBSERVATION REPORT. REMEDY: COMPLY WITH COMMISSIONER'S ORDER.
#35718816N
Dec 17, 2026
PENDING
$2,500
Jun 12, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.I OBSERVED HAZARDOUS CONDITION ON THE EXTERIOR PARAPET WALL TO THE BLDG.LEFT SIDE TOP-CORNER OF EXP.ONE DISLODGE COPPING STONE AT EDGE FOUND CRACKED IN TW
#35683167P
Aug 21, 2025
IN VIOLATION
$2,500
DOB (4)
IssuedViolationStatus
Jul 15, 2025CONSTRUCTION
EMERGENCY WORK-ON 6/12/25 DOB OBSVD INWARDLY AREA OF MASONRY ROOF PARAPET WALL W/CHIMNEY @ EXP4 REPORT ISSUED ON 7/14/25 & SIGNED & STAMPED BY SCOTT. J PROFETA,R.A INDICATED MASONRY CHASE REMOVED FROM BELOW THE ROOF LEAVING THE CHIMNEY ONLU PARTIALL SUPPORTED. COMPLY W/ CODE IMMED RETAIN NYSPE&GC TO
#PI10801SR
DOB VIOLATION - ACTIVE
Jun 12, 2025CONSTRUCTION
CORRECTIVE ACTION PLAN REQ'D. OBSVD DISLODGE COPPING STONE ON PARAPET WALL & OVER PUBLIC SIDEWALK LEANING PARAPET WALL 16X6 FT(L+H)2 EXP4 CRACKED MORTAR AROUND CHIMNEY # EXP3 PLUS OTHER BRICKS IN DISREPAIR @ ROOF LEVEL. OWNER TO IMMED RETAIN REG DESIGN PROF TO EVAL THE ENTIRE BLDG & SUBMIT CORRECTIV
#PI10801HZ
DOB VIOLATION - ACTIVE
Jun 12, 2025CONSTRUCTION
FTM BLDG IN CODE COMPLIANT MANNER-OBSVD DISLODGE AND CRACKED COPPING STONE ABOVE PARAPET WALL OF EXP1,LEANING PORTION OF PARAPET WALL AT EXP4 APPROX 16FT BY 6FT,CRACKED MORTAR AROUND THE CHIMNEY AT ROOF LEVEL. AN ANNUAL PARAPET OBSERVATION REPORT IS REQ'D TO BE COMPLETED FOR ENDING YEAR 2025
#PI10802HZ
DOB VIOLATION - ACTIVE
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#00723
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
HPD (31) · C 9 · B 20 · A 2
IssuedClassViolationCorrect by
Oct 13, 2026CApt 1A · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOct 11, 2026
Oct 13, 2026B§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT BASEMENTNov 17, 2026
Sep 3, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT PUBLIC HALL, 1st STORYOct 8, 2026
Aug 26, 2026B§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FRONT BUILDING ENTRANCE AT STOOPSep 30, 2026
Jun 12, 2026BApt 3C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT CEILING AND WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18637979 ISSUED 10-FEB-26 HAS BEEN UPGRADED TO CLASS B PER ADMIJul 17, 2026
May 21, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR AT PUBLIC HALL, 1st STORYJun 25, 2026
Apr 1, 2026BApt 3C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT CEILING AND WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18470614 ISSUED 29-NOV-25 HAS BEEN UPGRADED TO CLASS B PER ADMIMay 6, 2026
Feb 12, 2026CApt 3C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINLY FLOOR TILES IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTFeb 18, 2026
Feb 12, 2026BApt 3C · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTMar 19, 2026
Feb 12, 2026BApt 3C · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTMar 19, 2026
Feb 12, 2026CApt 3C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTFeb 18, 2026
Jan 28, 2026BApt 3C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 1O SQUARE FEET AT WEST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 18255750 ISSUED 26-SEP-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRMar 4, 2026
Dec 2, 2025BApt 3C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION AT WEST WALL IN THE BATHROOM LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 6, 2026
Dec 2, 2025CApt 3C · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTDec 16, 2025
Dec 2, 2025BApt 3C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 6, 2026
Dec 2, 2025CApt 3C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTDec 28, 2025
Dec 2, 2025BApt 3C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL STOPPER AT BATHTUB. IN THE BATHROOM LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 6, 2026
Nov 19, 2025B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING. AT PUBLIC HALL, 3rd STORYDec 24, 2025
Nov 19, 2025C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING A STOPPER INSTALLED AT BUILDING FRONT ENTRANCE DOORDec 3, 2025
Nov 19, 2025B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT PUBLIC HALL, 1st STORYDec 24, 2025
Oct 1, 2025CApt 3C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 7, 2025
Sep 30, 2025CApt 3C · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 14, 2025
Sep 30, 2025BApt 3C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTNov 4, 2025
Sep 30, 2025CApt 3C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 26, 2025
Sep 30, 2025BApt 3C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION AT WEST WALL IN THE BATHROOM LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTNov 4, 2025
Sep 30, 2025BApt 3C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTNov 4, 2025
Sep 11, 2025A§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT PUBLIC HALL, 1st STORYDec 15, 2025
May 20, 2024A§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER WELDED SHOE NEEDS TO BE BOLTED AT DROP LADDER OF FIRE ESCAPE AT BUILDING FRONT AT FIRE ESCAPEAug 23, 2024
Dec 30, 2020BApt G · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT G, 1st APARTMENT FROM NORTH AT EASTFeb 3, 2021
Dec 30, 2020BApt G · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT G, 1st APARTMENT FROM NORTH AT EASTFeb 3, 2021
Dec 30, 2020BApt G · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST AND SOUTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT G, 1st APARTMENT FROM NORTH AT EASTFeb 3, 2021

Issued in the last 120 days

DateSourceWhatNow
Oct 13, 2026HPD C§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOpen
Oct 13, 2026HPD B§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT BASEMENTOpen
Sep 3, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT PUBLIC HALL, 1st STORYOpen
Aug 26, 2026HPD B§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FRONT BUILDING ENTRANCE AT STOOPOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 11:24 AM ET. BBL 1014720044.