Bronx · Block 3030 · Lot 136 · 10457

405 East 182 Street

5 floors · 24 apartments · 20,250 sq ft · built 1915 · class C1 · owner of record: Nys Mgmt Llc

95open violations
$5,000ECB/OATH penalties owed
21HPD class C (immediately hazardous)
47dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-27 (Accepted). Agency page

Dec 31, 2026
in 47 days
1 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01

Open violations

ECB / OATH (13) · $5,000 owed
IssuedViolationHearingBalance
Jul 21, 2024Construction CLASS - 1
SUMMONS ISSUED FOR WORK WITHOUT A PERMIT DUE TO EXTERIOR FIRE ESCAPE EXTENDED AT 3RD FLOOR OF BUILDING AT EXPOSURE 1. NO PERMITS ON FILE, OBTAIN PERMIT
#39119513R
Nov 18, 2025
IN VIOLATION
$2,500
Jul 21, 2024Construction CLASS - 1
SUMMONS ISSUED FOR FAILURE TO MAINTAIN DUE DUE TO UNSECURED BRACKET ON FIRE ESCAPE AT 3RD FLOOR LEVEL AT EXPOSURE #1 OF BUILDING, REPAIR AND/REPLACE
#39119514Z
Nov 18, 2025
IN VIOLATION
$1,250
Jul 15, 2024Construction CLASS - 2
OCCUPANCY IN CONTRARY TO THAT ALLOWED BY C/O AND/OR DEPARTMENT OF BUILDING RECORD. ILLEGALLY CREATED ROOMS. 3RD STORY SOUTH 1 APARTMENT #3C ILLEGALLY SUB-DIVIDED STUDIO APARTMENT CREATED AT SOUTH 1 AND LARGE RO
#35483151Y
Apr 24, 2025
IN VIOLATION
$1,250
Jan 5, 2024Boilers CLASS - 1
FOUND WEIL MCLAIN STEAM 15PSI BOILER WITH A 30PSI SAFETY VALVE. CEASED USE DUE TO HAZARDOUS CONDITION.DO NOT OPERATE BOILER UNTIL HAZARDOUS CONDITIONS ARE IMMEDIATELY CORRECTED AND DOB IS NOTIFIED TO LIFT CEASE
#39102894Z
Mar 15, 2024
DEFAULT
$0
Feb 3, 2020Boilers CLASS - 2
BOILER NOT REGISTERED AS PER DOB RECORDS, PULL PERMIT BRING BOILER AND BOILER ROOM UP TO CURRENT CODE AND CALL FOR INSPECTION. REMOVE ALL COMBUSTIBLES FROM BOILER ROOM.
#39016729Y
Nov 27, 2020
IN VIOLATION
$0
Feb 3, 2020Boilers CLASS - 1
CEASE USE WEIL MCLAIN MODEL #878, DUE TO WATER LEAK COMING FROM BOILER, DO NOT OPERATE BOILER TIL ALL HAZARDOUS CONDITIONS ARE CORRECTED AND DOB IS NOTIFIED TO RE INSPECT TO LIFT CEASE USE ORDER
#39016727K
Nov 27, 2020
IN VIOLATION
$0
May 28, 2019Construction CLASS - 1
UNLAWFUL ACTS,FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.IN APRIL 2,18,2019 TWO ADMINISTRATIVE CODE VIOLATIONS WEA ISSUED TO THE RESPONDENT THE RESPONDENT FAILED TO COMPLY WITH NYCADMINISTRATIVE CODE #
#35359908Z
Jul 19, 2019
DEFAULT
$0
Apr 12, 2019Construction CLASS - 1
UNLAWFUL ACTS.FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER.IN MARCH 6 & 8,2019,2 ELECTRICAL VIOLATIONS WAS GIVEN TO THE RESPONDENT,THE RESPONDENT.THE RESPONDENT FAILED TO COMPLY W/ELECTRICAL CODE #27-3018(B
#35359867L
May 31, 2019
DEFAULT
$0
Mar 8, 2019Unknown CLASS - 1
ELECTRICAL WORK W/O A PERMIT. OBSERVED AT THE TIME OF MY INSPECTION A MAN INSTALLING FLUORESCENT LIGHT FIXTURE IN THE HALLWAY. I ASKED HIM FOR A PERMIT HE SAID NO ENGLISH. AT THAT TIME I ASKED HIM TO STOP WORKI
#35359011Y
Nov 29, 2019
IN VIOLATION
$0
Oct 22, 2018Unknown CLASS - 1
UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENTS, APPARATUS, MATERIALS, DEVICES, APPLIACNES, OR WIRING IN USE. OBSERVED EXTENSION CORDS USED AS PERMANENT WIRING,M OPEN UN() SWITCHES, AND JUNCTION BOXES, BEA
#35346224P
Mar 29, 2019
IN VIOLATION
$0
Aug 5, 2016Unknown CLASS - 2
ELECTRICAL WORK W/O A PERMIT.THE ENTIRE BLDG HALLWAYS:REPLACING LIGHTING FIXTURES."PLEASE NOTE" THIS IS NOT A FINAL INSPECTION.REMEDY:OBTAINPERMIT
#35202219H
Feb 10, 2017
IN VIOLATION
$0
Jun 29, 2005Boilers Non-Hazardous
BQ9/10/16/32A/34A/36/B4A/50/50A/50B/50C/50D. BQ9-BOILER INSTALLED WITHOUT PERMITS ISSUED AND NO SIGN OFF FOR WEILMCLAIN BOILER,WITH CARLIN OIL BURNER. 34A-#1 DOOR DOES NOT GO OUT TOWARDS EGRESS AND #2 DOOR MISS
#32047368P
Aug 19, 2005
IN VIOLATION
$0
Sep 24, 2004Boilers Hazardous
3B 50A 32A 34A 36 50G 50A 50B 50C 50D 50E 50F 50A EXCESSIVE FOOT ESCAPING FROM BOILER VSECTION 50B FLUE PIPE WILL COLLAPOSED NEED SUPPORT STRAPS 50C PIPE SAFETY OR RELIEF VALUE UPRIGHT 50D MANUEL RESET CONTROLL
#32045509K
Sep 20, 2011
IN VIOLATION
$0
DOB (23)
IssuedViolationStatus
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#09519
DOB VIOLATION - ACTIVE
Sep 2, 2020FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#02278
DOB VIOLATION - ACTIVE
May 29, 2019FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00240
DOB VIOLATION - ACTIVE
Jan 23, 2019FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00190
DOB VIOLATION - ACTIVE
Oct 1, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
#04987
DOB VIOLATION - ACTIVE
Mar 1, 2013LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
#04300
DOB VIOLATION - ACTIVE
Dec 31, 2009LOW PRESSURE BOILER

#07168
DOB VIOLATION - ACTIVE
Jan 3, 2008LOCAL LAW 62/91 - BOILERS

#09264
DOB VIOLATION - ACTIVE
Jan 19, 2007LOCAL LAW 62/91 - BOILERS

#09784
DOB VIOLATION - ACTIVE
Jan 6, 2006LOCAL LAW 62/91 - BOILERS

#09363
DOB VIOLATION - ACTIVE
Jan 31, 2005LOCAL LAW 62/91 - BOILERS

#10066
DOB VIOLATION - ACTIVE
Feb 13, 2004LOCAL LAW 62/91 - BOILERS

#10769
DOB VIOLATION - ACTIVE
Mar 19, 2003LOCAL LAW 62/91 - BOILERS

#10085
DOB VIOLATION - ACTIVE
Mar 26, 2002LOCAL LAW 62/91 - BOILERS

#11119
DOB VIOLATION - ACTIVE
Feb 27, 2001LOCAL LAW 62/91 - BOILERS

#10257
DOB VIOLATION - ACTIVE
Feb 7, 2000LOCAL LAW 62/91 - BOILERS

#10648
DOB VIOLATION - ACTIVE
Mar 16, 1999LOCAL LAW 62/91 - BOILERS

#10503
DOB VIOLATION - ACTIVE
May 4, 1998LOCAL LAW 62/91 - BOILERS

#14140
DOB VIOLATION - ACTIVE
Sep 16, 1997LOCAL LAW 62/91 - BOILERS

#202325
DOB VIOLATION - ACTIVE
Feb 10, 1997LOCAL LAW 62/91 - BOILERS

#13638
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#19597
DOB VIOLATION - ACTIVE
Jun 9, 1994LOCAL LAW 62/91 - BOILERS

#04736
DOB VIOLATION - ACTIVE
May 17, 1993LOCAL LAW 62/91 - BOILERS

#04660
DOB VIOLATION - ACTIVE
DOB NOW Safety (24)
IssuedViolationStatus
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
Sep 2, 2020AEUHAZ FTC-AEU-HAZ
Active
May 29, 2019AEUHAZ FTC-AEU-HAZ
Active
Jan 23, 2019AEUHAZ FTC-AEU-HAZ
Active
Oct 1, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
Active
Mar 1, 2013Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT
Active
Dec 31, 2009Boiler LBLVIO
Active
Jan 3, 2008Boiler LL6291
Active
Jan 19, 2007Boiler LL6291
Active
Jan 6, 2006Boiler LL6291
Active
Jan 31, 2005Boiler LL6291
Active
Feb 13, 2004Boiler LL6291
Active
Mar 19, 2003Boiler LL6291
Active
Mar 26, 2002Boiler LL6291
Active
Feb 27, 2001Boiler LL6291
Active
Feb 7, 2000Boiler LL6291
Active
Mar 16, 1999Boiler LL6291
Active
May 4, 1998Boiler LL6291
Active
Sep 16, 1997Boiler LL6291
Active
Feb 10, 1997Boiler LL6291
Active
Aug 29, 1995Boiler LL6291
Active
Jun 9, 1994Boiler LL6291
Active
May 17, 1993Boiler LL6291
Active
HPD (36) · C 21 · B 14 · A 1
IssuedClassViolationCorrect by
Oct 13, 2026CApt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM SOUTH AT WESTNov 8, 2026
Oct 13, 2026CApt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM SOUTH AT WESTNov 8, 2026
Oct 13, 2026CApt 5E · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 2nd APARNov 8, 2026
Sep 10, 2026C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DISCARDED REFRIDGERATOR WITH DOOR INTACT YARDSep 16, 2026
Aug 12, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCHSET AT DOOR LEADING TO NORTH YARD AT PUBLIC HALL, 1st STORYAug 26, 2026
Jun 9, 2026BApt 5E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT EAST WALL AND AROUND WINDOW IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM SOUTH AT WESTJul 14, 2026
Jun 9, 2026B§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLES AT LANDING AT 1st PUBLIC HALL BULKHEAD FROM NORTH, 5th STORYJul 14, 2026
May 26, 2026BApt 3A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE , LIFTING CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTJun 30, 2026
May 26, 2026B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXIGLASS INSTALLED AT SIDELIGHTS AT BUILDING ENTRANCE (FROM STREET TO VESTIBULE) , 1st STORYJun 30, 2026
May 26, 2026BApt 5E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10SQFT AT NORTH, EAST WALL AND CEILING IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM SOUTH AT WESTJun 30, 2026
May 26, 2026CApt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM SOUTH AT WESTJun 21, 2026
May 26, 2026CApt 5C · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH AJun 19, 2026
May 26, 2026B§ 27-2005 ADM CODE PROVIDE APPROVED GLASS AT SIDELIGHTS AT BUILDING ENTRANCE (FROM STREET TO VESTIBULE) , 1st STORYJun 30, 2026
May 26, 2026BApt 5C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ.FT AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 30, 2026
May 26, 2026CApt 3A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTJun 21, 2026
May 12, 2026CApt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM SOUTH AT WESTJun 7, 2026
May 12, 2026CApt 3B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM NORTH AT EASTJun 7, 2026
May 12, 2026CApt 3B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM NORTH AT EASTJun 7, 2026
Jan 26, 2026CApt 4A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 30 SQUARE FEET OF MOLD AT CEILING, EAST, NORTH, SOUTH, AND WEST WALLS IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM NORTH AT EASTFeb 21, 2026
Jan 6, 2026BApt 5A · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM NORTH AT EASTFeb 10, 2026
Dec 22, 2025BApt 4A · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM NORTH AT EASTJan 26, 2026
Dec 22, 2025BApt 2D · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 26, 2026
Dec 22, 2025BApt 1E · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 1E, 1st STORY, 2nd APARTMENT FROM SOUTH AT WESTJan 26, 2026
Dec 11, 2025CApt 5E · § 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS.Dec 15, 2025
Dec 11, 2025CApt 5E · § 27-2056.7 ADM CODE: CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES.Dec 15, 2025
Oct 15, 2025CApt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM SOUTH AT WESTNov 10, 2025
Sep 5, 2025BApt 3A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 30SQFT AT NORTH WALL AND WEST WALL IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTOct 10, 2025
Sep 2, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCHSET AT DOOR LEADING TO NORTH YARD AT PUBLIC HALL, 1st STORYSep 16, 2025
Aug 11, 2025CApt 4A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQ.FT AT CEILING, NORTH AND WEST WALLS IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM NORTH AT EASTSep 6, 2025
Jul 17, 2025AApt 2D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 20, 2025
Jul 25, 2024B§ 300, 301, 302, M/D LAW FILE PLANS AND OBTAIN A CERTIFICATE OF OCCUPANCY TO LEGALIZE THE FOLLOWING ALTERATION OR RESTORE PREMISES TO PRIOR LEGAL CONDITION 5 STORY 24 CLASS ''A'' APARTMENTS ILLEGALLY CONVERTED TO 26 APARTMENTS AND AN ADDITIONAL ROOM BY CREATING 1 CLASS ''A'' APARTMENT AT CELLAR AND Aug 29, 2024
Jul 2, 2024BApt 3B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM FROM BUILDING ENTRANCE DOOR TO THE APARTMENT WALL PANEL AT SOUTH WALL IN THE FOYER LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM NORTH AT EASTAug 6, 2024
Dec 19, 2023CApt 4C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 14, 2024
Dec 19, 2023CApt 4C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 14, 2024
May 1, 2018CApt 5D · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM EAST AT SOUTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED ATJun 12, 2018
Jul 16, 2007CApt 2A · § 27-2056.7 ADM CODE -CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNERAug 11, 2007

Issued in the last 120 days

DateSourceWhatNow
Oct 13, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Oct 13, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Oct 13, 2026HPD C§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 2, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 2nd APAROpen
Sep 10, 2026HPD C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DISCARDED REFRIDGERATOR WITH DOOR INTACT YARDOpen
Aug 12, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM NORTH AT EASTClosed
Aug 12, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BUILDING ENTRANCE DOORClosed
Aug 12, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER SASH WINDOW AT EAST WALL IN THE KITCHEN LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM NORTH AT EASTClosed
Aug 12, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE UPPER SASH WINDOW AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM NORTH AT EASTClosed
Aug 12, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCHSET AT DOOR LEADING TO NORTH YARD AT PUBLIC HALL, 1st STORYOpen
Jul 20, 2026HPD B§ 27-2021 ADM CODE PROVIDE SUFFICIENT, PROPER AND SEPARATE METAL RECEPTACLES FOR THE DEPOSIT OF GARBAGE, RUBBISH AND OTHER WASTE MATERIAL AND ARRANGE FOR COLLECTION AND DISPOSAL OF SUCH MATERIAL.Closed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 11:15 AM ET. BBL 2030300136.

Look up another building