Bronx · Block 4821 · Lot 51 · 10466

4040 Bronx Boulevard

6 floors · 58 apartments · 54,177 sq ft · built 1929 · class D1 · owner of record: 4040 Ba Llc D

21open violations
$15,625ECB/OATH penalties owed
7HPD class C (immediately hazardous)
69dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 69 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 85 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 54,177 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 190 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 190 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 313 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 434 days
Next cycle year 2027
Energy audit and retro-commissioning (2031) Likely applies
Local Law 87 · Calendar year 2031
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 4821). Agency page

Dec 31, 2031
in 1895 days
Next due 2031
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-12 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (6) · $15,625 owed
IssuedViolationHearingBalance
Jan 27, 2026Elevators CLASS - 2
CLASS 2 ITEMS: CAR GUIDE SHOES AR WORN AND NEED TO BE REPLACED. CAR DOOR NOISY WHEN OPENING AND CLOSING. EFFECT REPAIR. FIRE FIGHTERS SERVICE CALL CANCELL BUTTON MISSING IN CAR OPERATING PANEL. CLEAN ENTIRE MAC
#39175068Y
Apr 3, 2026
DEFAULT
$3,125
Apr 8, 2025Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #919290. REMEDY: SUBMIT ACCEPTABLE REQU
#37035088Y
Aug 1, 2025
ADMIT/IN-VIO
$0
Jul 30, 2024Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR WALLS/FACADE AND APPURTENANCES:OBSERVED MULTIPLE DETERIORATING CONDITION OF BUILDING FACADE AT EXPOSURE 1 AND EXPOSURE 2:LOOSE BRICKS CRACK/STEP CRACK DEGRADED/OPEN MORTAR JOINTS BR
#35684000H
Oct 4, 2024
DEFAULT
$3,125
Jul 30, 2024Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY AT THE TIME OF INSPECTION VIEW ITEMS STORED AT FIVE ESCAPE LAND AT EXPOSURE 3.EAST REM:REMOVE EGRESS OBSTRUCTION.
#35684001J
Oct 4, 2024
DEFAULT
$3,125
May 22, 2024Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED AT EXPOSURE 1 WEST DISPLACED/BULGING STACKED BOND BRICK RIGHT OF 5TH FL. WINDOW NORTH WEST END.-CRACKED BRICK, SILL
#35685285P
Aug 2, 2024
DEFAULT
$6,250
Jan 5, 2016Elevators CLASS - 1
97-X-10:CLASS 1 -FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER SERVICE EQUIPMENT ELEVATOR PER BC 3001.2;27-987 DOB RECORDS SHOWS THE ONLY ELEVATOR DEVICE IN BLDG AS ACTIVE.UPON INSP THE DEVICE IS FOUND TO B
#38239099K
Feb 19, 2016
WRITTEN OFF
$0
DOB (3)
IssuedViolationStatus
May 22, 2024CONSTRUCTION
EMERGENCY WORK ORDER DUE TO CRACKING/DISPLACED/BULGING STACKED BOND BRICK RIGHT OF 5FL WINDOW OF EXP#2 WEST.EXP#1 WEST EXP#2 NORTH HAVE CRACKED BRICK, WINDOW SILLS MULTIPLE LOCATIONS PRESENTING A SEVERE HAZARD TO THE PUBLIC. REMEDY:TAKE & PROVIDE ADEQUATE SAFETY MEASURES TO SECURE PUBLIC SAFETY AS S
#LL21201DD
DOB VIOLATION - ACTIVE
Feb 22, 2024NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
#01318
DOB VIOLATION - ACTIVE
Nov 8, 2019LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
#03801
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Jan 14, 2026Facades FTC-FC-UNSAFE
Unsafe report filed
Active
Feb 22, 2024Facades FISPNRF
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
Active
Nov 8, 2019Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Active
HPD (12) · C 7 · B 5 · A 0
IssuedClassViolationCorrect by
Aug 15, 2025CApt 3B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 3B, Sep 8, 2025
Aug 15, 2025CApt 3B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM EAST AT SOUTH WALL DOOR, 1st CLOSET FROM EAST AT SOUTH WALL DOOR FRAMESep 8, 2025
Aug 15, 2025BApt 3B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTSep 19, 2025
Aug 15, 2025CApt 3B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM SOUTH AT WEST WALL IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT ASep 8, 2025
Aug 15, 2025CApt 3B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) BASEBOARD AT WEST WALL, 1st CLOSET FROM NORTH AT EAST WALL DOOR, 1st CLOSET FROM NORTHSep 8, 2025
Aug 14, 2025BApt 3B · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTSep 18, 2025
Aug 14, 2025CApt 3B · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE INOPERABLE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTAug 28, 2025
Aug 14, 2025BApt 3B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MEDICINE CABINET AT WEST WALL IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTSep 18, 2025
Jun 16, 2025B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSE HOLD ITEMS AT WEST EXTERIOR AT FIRE ESCAPE, 4th STORYJul 21, 2025
May 2, 2025BApt 6D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6D, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTJun 6, 2025
Feb 23, 2023CApt 6E · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 2ndMar 19, 2023
Feb 23, 2023CApt 6E · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM EAST AT SOUTH WALL DOOR FRAME IN THE FOYER LOCATED AT APT 6E, 6th STORMar 19, 2023

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 7:22 AM ET. BBL 2048210051.