| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 46 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 62 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 31,200 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 167 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 167 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 290 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1142 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-13 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 23, 2026 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION: OBSERVED THE FOLLOWING. LOOSE/DEFECTED SECTION OF SHED PARAPET CORNER OF EXPOSURE 1 AND 2. REMEDY: COMPLY TO CODE SPECIFICATION. #35730730Y | Nov 20, 2026 PENDING | $2,400 |
| Jun 8, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED AT EXPOSURE 1 OF MIXED-USE 6-STORY BUILDING NOT MAINTAINED IN COMPLIANCE WITH CODE- SHED POSTS INSTALLED LESS THAN 18 INCHES FROM CURB, CREATING POTENTIAL VEHICLE I #39555218P | Mar 19, 2027 PENDING | $2,400 |
| Mar 25, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #1 EAST (1)STEP CRACKED BRICK/MORTARJOINTS, NORTH EAST CORNER OF PARAPET.-EXP #3 WEST-(1)CRACKED/SPALLING/ #35727014X | Nov 6, 2026 IN VIOLATION | $5,000 |
| Oct 8, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER/BLDG WALLS ON APPURTENANCES. OBSERVED COPING STONE APPROX 10 IN X 3FT FALLEN FROM LEFT HANDCORNER. REMEDY: MAINTAIN BLDG WALLS. #35452263R | Nov 29, 2019 STIPULATION/IN-VIO | $0 |
| Aug 22, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS NOTED AT TIME OF INSPECTION OBSERVED COING STONE APPROX 10 IN X 3 FT FALLEN FROM TO LEFT HAND CORNER 9EXPOSURE 1&2) AND LANDED ON PULIC SIDEWALK REPAIR DEFECTS MAINTAIN BUILDI #35407681R | Oct 18, 2019 IN VIOLATION | $12,500 |
| Issued | Violation | Status |
|---|---|---|
| Jul 23, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. DETERIORATION OF BLDG @ EXP1,2&3:CRACKS,STEP CRACKS DAMAGED JOINTS AND BOWED LINTELS CRACK WINDOW PANE AT EXP3.EXP4 DAMAGED WINDOW SILL, SPALLING AND DAMAGED JOINTS. REMEDY: REPAIR AND/OR REPLACE #SR0702NS | DOB VIOLATION - ACTIVE |
| Apr 4, 2025 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE: OBSERVED @ EXP#1 MULTIPLE CRACKED SPALLING WINDOW SILL @ EXP#2 MULTIPLE CRACKED WINDOW SILLS AND SPALLING. AT EXP#3-OBSERVED SPALLING PAINT/TAR MULTIPLE LOCATION & A STEP CRACK. REMEDY: FIX AND/OR REPLACE #SR20702DO | DOB VIOLATION - ACTIVE |
| Nov 13, 2019 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00244 | DOB VIOLATION - ACTIVE |
| Aug 23, 2019 | CONSTRUCTION EMERG WRK ORD:PARAPET COPING STONE@EXP1/2 CRNR FELL ON 8/22/19.COPING STONE@EXP1/2 CRNR@RISK OF COLLAP ONTO 1STORY MEDICAL OFFICE ROOF.EXP3 BRICKS@ROOF PART DETACHED FROM STRUCT& @RISK OF COLLAP INTO EXP3 REAR YARD.OWN RETAIN PE CONTR IMMED TEMP BRACE OR REMOVE LOOSE COPING STONE INSTL SHED@EXP3.WRK #FEU20701PN | DOB VIOLATION - ACTIVE |
| Aug 23, 2019 | CONSTRUCTION FTM:COPING STONE@EXP 1/2 FELL TO SIDEWALK ON 8/22/19.STEEL DUNNAGE@EXP 3/4 CRNR BEARING ON PARAPET WALL.EXP3 BRICK CHIMNEY HAD PART DETACHED BRICKS 4'LONG AT RISK OF PART COLLAP INTO REAR YARD.OWNR RETAIN PE TO EVAL ENTIRE BLDG INCL ROOF,PARAPET,CONNECT,CHIM&FACADES.PE TO PREPARE REPR DWGS.REPRS TO #FEU20702PN | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 13, 2019 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 2, 2026 | B | Apt 26 · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE BATHROOM LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Dec 7, 2026 |
| Nov 2, 2026 | B | Apt 26 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Dec 7, 2026 |
| Nov 2, 2026 | B | Apt 26 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... OBSERVED MORE THAN 10 SQ FT AT NORTH AND EAST WALL IN THE BATHROOM LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Dec 7, 2026 |
| Oct 30, 2026 | C | Apt 56 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 56, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 25, 2026 |
| Oct 30, 2026 | C | Apt 56 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 56, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 25, 2026 |
| Oct 30, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR LEADING TO ROOF AT 1st PUBLIC HALL BULKHEAD FROM EAST, 6th STORY | Nov 13, 2026 |
| Oct 30, 2026 | B | Apt 56 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE CLOSET IN THE FOYER LOCATED AT APT 56, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 4, 2026 |
| Oct 30, 2026 | B | Apt 56 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE CLOSET IN THE FOYER LOCATED AT APT 56, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 4, 2026 |
| Oct 30, 2026 | B | Apt 56 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE CLOSET IN THE PRIVATE HALLWAY LOCATED AT APT 56, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 4, 2026 |
| Oct 30, 2026 | B | Apt 56 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE CLOSET IN THE PRIVATE HALLWAY LOCATED AT APT 56, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 4, 2026 |
| Sep 18, 2026 | B | Apt 26 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 23, 2026 |
| Sep 18, 2026 | B | Apt 26 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 23, 2026 |
| Sep 18, 2026 | B | Apt 26 · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE DRAIN PIPE AT BATHTUB IN THE BATHROOM LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 23, 2026 |
| Sep 18, 2026 | B | Apt 26 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 23, 2026 |
| Sep 18, 2026 | C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | Oct 14, 2026 |
| Apr 30, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 3, 2026 |
| Jun 9, 2025 | C | Apt 34 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 34, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jun 23, 2025 |
| Jun 9, 2025 | B | Apt 34 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE BOTTOM SHELF AT SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 34, 4th STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jul 14, 2025 |
| Jun 4, 2025 | C | Apt 26 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 30, 2025 |
| Jun 4, 2025 | C | Apt 26 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ FT AT ALL WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 30, 2025 |
| Date | Source | What | Now |
|---|---|---|---|
| Nov 2, 2026 | HPD B | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTELINE AT BATHTUB IN THE BATHROOM LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Nov 2, 2026 | HPD B | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Nov 2, 2026 | HPD B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... OBSERVED MORE THAN 10 SQ FT AT NORTH AND EAST WALL IN THE BATHROOM LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 30, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 56, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Oct 30, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 56, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Oct 30, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR LEADING TO ROOF AT 1st PUBLIC HALL BULKHEAD FROM EAST, 6th STORY | Open |
| Oct 30, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE CLOSET IN THE FOYER LOCATED AT APT 56, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Oct 30, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE CLOSET IN THE FOYER LOCATED AT APT 56, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Oct 30, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE CLOSET IN THE PRIVATE HALLWAY LOCATED AT APT 56, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Oct 30, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE CLOSET IN THE PRIVATE HALLWAY LOCATED AT APT 56, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 18, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 18, 2026 | HPD B | § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 18, 2026 | HPD B | § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE DRAIN PIPE AT BATHTUB IN THE BATHROOM LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 18, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 26, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Sep 18, 2026 | HPD C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | Open |
| Jul 23, 2026 | DOB | CONSTRUCTION: FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. DETERIORATION OF BLDG @ EXP1,2&3:CRACKS,STEP CRACKS DAMAGED JOINTS AND BOWED LINTELS CRACK WINDOW PANE AT EXP3.EXP4 DAMAGED WINDOW SILL, SPALLING AND DAMAGED JOINTS. REMEDY: REPAIR AND/OR REPLACE | Open |
| Jul 23, 2026 | ECB | Construction: PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION: OBSERVED THE FOLLOWING. LOOSE/DEFECTED SECTION OF SHED PARAPET CORNER OF EXPOSURE 1 AND 2. REMEDY: COMPLY TO CODE SPECIFICATION. | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)