5 floors · 1 apartments · 7,050 sq ft · built 1920 · class O5 · owner of record: 40 Water Street, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 50 days | Keep the report on file (not filed with DOB) |
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 294 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 781 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 9, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLER WHERE IS REQUIRED PER BC 903.2 AND 27-954, FOR TRANSIENT USE AT APT ON 5TH FLOOR FRONT. REMEDY: DISCONTINUE ILLEGAL #35727663X | Feb 4, 2027 | $2,500 |
| Apr 9, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.LACK OF REQUIREDNUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1(2008 CODE); 27-366; BC 1021.1(2014 CODE); BC 1006.3(2022 CODE), FOR TRANSIENT USE AT #35727662Y | Feb 4, 2027 | $2,500 |
| Apr 9, 2026 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE DEPT OF BUILDINGS RECORDS. ILLEGAL OCCUPANCY NOTED: THE APT 5TH FLOOR FRONT HAS BEEN CONVERTED/OCCUPIED AS TRANSIENT USE AND OCCUPIED BY 5 GUESTS FOR LESS THAN 30 DAYS #35727661M | Feb 4, 2027 | $2,500 |
| Apr 9, 2026 | Construction CLASS - 1 BC 907.2.8. FAILURE TO PROVIDE CLASS "J" FIRE ALARM SYSTEM FOR TRANSIENT USE AT APT ON 5TH FLOOR FRONT. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY. #35727664H | Feb 4, 2027 | $2,500 |
| Apr 8, 2022 | Elevators CLASS - 2 PHONE NOT WORKING, POVIDE ACESS TO MOTOR ROOM #39060024M | Jul 28, 2022 STIPULATION/IN-VIO | $315 |
| Feb 4, 2022 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT TIME OFMY INSPECTION I OBSERVED AT EXPOSURE 1 & 2 VERTICAL CRACK IN MASONRY AT CORNER OF EXPOSURE 1 AND 2 APPROX 40X34 ALSO AT EXPOSURE 4 AT 4 FLOO #35644233M | Aug 25, 2022 IN VIOLATION | $1,250 |
| Dec 10, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT TIME OF INSPECTION NOTED VERTICAL CRACK IN MASONRY AT CORNER OF EXPOSURE#1 AND #2 APPROX.40'X34'ALSO AT EXPOSURE#1 DECORATIVE CORNICE AT PARAPET CRACKED #35636092H | Jan 5, 2023 IN VIOLATION | $1,563 |
| Oct 12, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES.AT THE TIME OF INSPECTION AT EXP-1 AND EXP-2 BETWEEN 2ND AND 3RD FLOOR CRACKS AND BRICKDAMAGE,MISSING BRICKS VERTICAL CRACK IN LEFT SIDE(WATER ST SIDE),BNCK #35592090M | Jul 20, 2023 IN VIOLATION | $6,250 |
| Aug 31, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING EXTERIOR PRIOR NOV #35581047N EXP #1 BETWEEN 2ND AND 3RD FLOOR WINDOWS CRACKED AN DELAMINATING BRICK FACE WITH LOOSE PCS OVER PUBLIC SIDEWALK.REMEDY:REPAIR FACADE DEFECTS. #35584528H | May 19, 2022 IN VIOLATION | $0 |
| Jul 19, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE CERTIFICATE OF CORRECTION WITH DEPT OF BUILDINGS FOR VIOLATING CONDITIONS CITED ON NOV #35299007J ISSUED ON 10/31/2017 PURSUANT TO SECTION 28-201.1;28-204.2 #35584759P | Feb 3, 2022 IN VIOLATION | $1,250 |
| Jul 19, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE CERTIFICATE OF CORRECTION WITH DEPT OF BUILDINGS FOR VIOLATING CONDITIONS CITED ON NOV #35298636H ISSUED ON 10/31/2017 PURSUANT TO SECTION 28-201.1;28-204.2; #35584757L | Feb 3, 2022 IN VIOLATION | $1,250 |
| Jul 19, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE CERTIFICATE OF CORRECTION WITH DEPT OF BUILDINGS FOR VIOLATING CONDITIONS CITED ON NOV #35298637J ISSUED ON 10/31/2017 PURSUANT TO SECTION 28-201.1;28-204.2 #35584763H | Feb 3, 2022 IN VIOLATION | $1,250 |
| Jul 19, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES.NOTED:AT TIME OF INSPECTION AT EXP #1 AND #2 CRACKS AND BRICK DAMAGE MISSING BRICKS MORTAR VERTICAL CRACK FROM ROOF TO FIRST FLOOR ON WATER STREET AND COENT #35581047N | May 19, 2022 IN VIOLATION | $2,500 |
| Jul 19, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE CERTIFICATE OF CORRECTION WITH DEPT OF BUILDINGS FOR VIOLATING CONDITIONS CITED IN NOV#35299008L ISSUED ON 10/31/2017 PURSUANT TO SECTION 28-201.1;28-204.2; #35584758N | Feb 3, 2022 IN VIOLATION | $1,250 |
| Jul 19, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE CERTIFICATE OF CORRECTION WITH DEPT OF BUILDINGS FOR VIOLATING CONDITIONS CITED ON NOV #3529864OK ISSUED ON 10/31/2017 PURSUANT TO SECTION 28-201.1;28-204.2 #35584760M | Feb 3, 2022 IN VIOLATION | $1,250 |
| Jul 19, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE CERTIFICATE OF CORRECTION WITH DEPT OF BUILDINGS FOR VIOLATING CONDITIONS CITED ON NOV #35298638L ISSUED ON 10/31/2017 PURSUANT TO SECTION 28-201.1;28-204.2 #35584762X | Feb 3, 2022 IN VIOLATION | $1,250 |
| Jul 19, 2021 | Construction CLASS - 2 FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OFCORRECTION W/ THE DOB FOR VIOLATING CONDITIONS CITED ON NOV#35298636H ISSUED ON:10/31/17 PURSUANT TO SECTION:28-201.1;28-204.2;1RCNY 102-01. #35584761Y | Feb 3, 2022 IN VIOLATION | $1,250 |
| Mar 17, 2020 | Elevators CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; INSTALL DLM AND PERFORM AND FILE TEST WITH NYCDOB. MACHINE HAS OIL LEAK. NO ACCESS TO PIT, PLEASE PR #39019839Z | Apr 15, 2021 IN VIOLATION | $1,250 |
| Oct 31, 2017 | Plumbing CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.LACK OF A SYSTEM OF AUTOMATIC SPRINKLER WHERE IS REQD AS PER BC908.2 AND 27-954 FOR TRANSIENT USE.REM:DISCONTINUE ILLEGAL OCCUPANCY. #35298637J | May 10, 2018 IN VIOLATION | $0 |
| Oct 31, 2017 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY.NOTED:AT MAIN STAIRCASE EXIT PASSAGEWAY BETWEEN 3RD FL AND 4TH FL OBSTRUCTED BY LADDER AND GARBAGE BAGS AND OTHER MISCELLANEOUS MATERIALS.REM:REMOVE OBSTRUCTION #35298640K | May 10, 2018 IN VIOLATION | $0 |
| Oct 31, 2017 | Construction CLASS - 1 WORK W/O PERMIT.AT 4TH FL-INSTALLED WATER&WASTE LINEDS FOR 2 WASH MACHINE;AT 3RD FL ERECTED FULL HEIGHT PARTITION WALLS TO CREATE 4 BEDROOMS, KITCHEN AND LIVING ROOM INSTALLED WATER&WASTE LINES FOR 3PC BATHRM ( #35298639N | May 10, 2018 IN VIOLATION | $0 |
| Oct 31, 2017 | Construction CLASS - 1 BC907.2.8:FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE.REM:DISCONTINUE ILLEGAL OCCUPANCY #35298638L | May 10, 2018 IN VIOLATION | $0 |
| Oct 31, 2017 | Quality of Life CLASS - 2 RESIDENCE ALTERED AS A DWELLING FOR MORE THAN THE NUMBER OF FAMILIES LEGALLY AUTHORIZED BY THE C OF O#86975.RESIDENCE NOW ALTERED AS 2 ALTERATION NOTED.AT 3RD FLR CREATED AND OCCUPIED AS A CLASS "A" APT WITH FU #35299008L | May 10, 2018 IN VIOLATION | $0 |
| Oct 31, 2017 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O#86975 ILLEGAL OCCUPANCY.NOTED:APT AT 5TH AND 3RD FLR HAS BEEN CONVERTED USE AS A TRANSIENT USE ALSO APT AT 3RD FLR HAS BEEN CONVERTED FROM OFFICE USE TO CLASS A #35299007J | May 10, 2018 IN VIOLATION | $0 |
| Oct 31, 2017 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG INCODE-COMPLIANT MANNER,FAILURE TO PROVIDE#OR REQD MEANS OF EGRESS FOR EVERY FLOOR PER BC1018.1 ABD 27.366 FOR TRANSIENT USE.REM:DISCONTINUE ILLEGAL OCCUPANCY. #35298636H | May 10, 2018 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 5, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00001 | DOB VIOLATION - ACTIVE |
| Oct 13, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00001 | DOB VIOLATION - ACTIVE |
| Jan 28, 2021 | ELEVATOR #9027/696471 | DOB VIOLATION - ACTIVE |
| Sep 2, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00038 | DOB VIOLATION - ACTIVE |
| Mar 17, 2020 | ELEVATOR #9027/675596 | DOB VIOLATION - ACTIVE |
| Jan 24, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00005 | DOB VIOLATION - ACTIVE |
| Jan 24, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00004 | DOB VIOLATION - ACTIVE |
| Jan 24, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00003 | DOB VIOLATION - ACTIVE |
| Jan 24, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00002 | DOB VIOLATION - ACTIVE |
| Mar 7, 1997 | CONSTRUCTION #0A01 | VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Jan 5, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 13, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 2, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 24, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 24, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 24, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| Jan 24, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 11, 2026, 12:38 PM ET. BBL 1000300034.