Queens · Block 402 · Lot 25 · 11101

40-03 29 Street

6 floors · 56,156 sq ft · built 2007 · class H9 · owner of record: Laxmi Management Llc

55open violations
$2,500ECB/OATH penalties owed
1HPD class C (immediately hazardous)
187dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 56,156 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 797 days
Next cycle year 2028
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 402). Agency page

Dec 31, 2032
in 2258 days
Next due 2032
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-06 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (23) · $2,500 owed
IssuedViolationHearingBalance
Aug 11, 2026Construction CLASS - 2
FAILURE TO CERTIFY; VIOLATION NUMBER 35656652P, FILE A CERTIFICATE OF CORRECTION
#39200144Z
Dec 15, 2026
PENDING
$1,250
Aug 11, 2026Construction CLASS - 2
FAILURE TO CERTIFY; VIOLATION NUMBER 35656654Z, FILE A CERTIFICATE OF CORRECTION
#39200143R
Dec 15, 2026
PENDING
$1,250
Jan 28, 2026Elevators CLASS - 1
CLASS 1 RTS:FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION,DEVICE IF FOUND TO BE OUT OF SERVICE SINCE 1/12/26,CREATING A HAZARDOUS CO
#39175249N
Apr 7, 2026
IN VIOLATION
$0
Jan 13, 2026Elevators CLASS - 1
CLASS 1: ELEVATOR DEVICE IS OUT OF SERVICE FOR AN EXTENDED PERIOD OF TIME AND NOT MAINTAINED IN A SAFE OPERATING CONDITION. SUBJECT ELEVATOR SERVES ADDITIONAL REQUIRED STOPS INCLUDING THE PARKING GARAGE, REDUCI
#39173630N
Mar 24, 2026
IN VIOLATION
$0
Jan 13, 2026Unknown CLASS - 2
FAILURE TO INSTALL GROUND-FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION AS REQUIRED. OBSERVED IN THE HOT WATER TANK ROOMS THAT THE PUMPS WAS NOT PROTECTED BY GFCI, INSTALL GFC1 PROTECTION
#39174202L
Mar 24, 2026
IN VIOLATION
$0
Jan 13, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:NO FIRESTOPPINGPER BC 712.3(2014 CODE);27-345;BC 711.2.4(2022 CODE) OBSERVED PLASTIC PANELS OVER HOLES LOCATED IN THE ELECTRICAL ROOM AND BASEMENT PREVIOUS
#39174209Y
Mar 24, 2026
IN VIOLATION
$0
Jan 13, 2026Construction CLASS - 1
UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. OBSERVED EXCESSIVE STORAGE IN ELECTRICAL ROOMS THROUGHOUT BUILDING. (WOOD TABLES, BAGS.) POTENTIAL FIRE HAZARD PREVIOUS VIOLATING #39145498R, MAINTAIN STORA
#39174208M
Mar 24, 2026
IN VIOLATION
$0
Jan 13, 2026Construction CLASS - 2
OBSERVED THROUGHOUT BUILDING SPRINKLER HEADS OBSTRUCTED. SIX FLOOR NO FIRE STOP AROUND PIPE PENETRATING THROUGH WALL. IN MECHANICAL ROOM FLOORS 2,3,4, 5, AND 6 WATER HEATERS NOT WORKING. BASEMENT FUTURE ON GAS
#39173632R
Mar 24, 2026
IN VIOLATION
$0
Jan 2, 2026Elevators CLASS - 2
REPAIR AND RESTORE TO SERVICE
#39172249J
Mar 10, 2026
IN VIOLATION
$0
Apr 21, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:NO FIRESTOPPING PER BC 712.3(2014 CODE);27-345;BC 711.2.4(2022 CODE)OBSERVED HOLE PENETRATIONS THROUGHOUT BUILDING.POTENTIAL FIRE HAZARD.REM:PROVIDE/MAINTAI
#35656652P
Aug 12, 2025
IN VIOLATION
$0
Apr 21, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.OBSERVED EXCESSIVE AMOUNTS OF FALLEN PLASTER AND DEBRY THROUGHOUT BY THE BUILDING.ADJACENT TO THE HOT WATER HEATER ROOMS.RESULTS OF WATER LEAK/DAMAGE.REM:RE
#35656655K
Aug 12, 2025
IN VIOLATION
$0
Apr 21, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS THROUGHOUT BUILDING. POTENTIAL FIRE HAZARD., PROVIDE/M
#39145495L
Oct 28, 2025
IN VIOLATION
$0
Apr 21, 2025Construction CLASS - 1
UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. OBSERVED EXCESSIVE STORAGE IN ELECTRICAL ROOMS THROUGHOUT BUILDING. (WOOD TABLES, RADIO, CLEANING PRODUCTS, BUCKETS, BIG GARBAGE BAGS.) POTENTIAL FIRE HAZAR
#39145498R
Oct 28, 2025
IN VIOLATION
$0
Apr 21, 2025Construction CLASS - 2
EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING DOORS THROUGHOUT BUILDING. POTENTIAL FIRE HAZARD., REPAIR/REPLACE DOOR
#39145496N
Oct 28, 2025
IN VIOLATION
$0
Apr 21, 2025Construction CLASS - 2
EXIT DOOR NOT SELF-CLOSING.OBSERVED NON SELF CLOSING DOORS THROUGHOUT BUILDING.POTENTIAL FIRE HAZARD.REM:REPAIR & REPLACE.
#35656653R
Aug 12, 2025
IN VIOLATION
$0
Apr 21, 2025Construction CLASS - 1
UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT.OBSERVED EXCESSIVE STORAGE IN THE ELECTRICAL ROOMS THROUGHOUT BUILDING.WOOD TABLES,RADIN,CLEANING PRODUCTS BUCKETS,BIG GARBAGE BAGES POTENTIAL FIRE HAZARDS.R
#35656654Z
Aug 12, 2025
IN VIOLATION
$0
Apr 14, 2025Elevators CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE ONLY DEVICE IN THE SECTION OF THE BUILDING IS FOUND TO BE OUT OF SERVICE, CREATIN
#39144756X
Jun 24, 2025
IN VIOLATION
$0
Apr 14, 2025Elevators CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE ONLY DEVICE IN THE SECTION OF THE BUILDING IS FOUND TO BE OUT OF SERVICE, CREATIN
#39144757H
Jun 24, 2025
IN VIOLATION
$0
Jan 24, 2025Elevators CLASS - 1
ENTIRE DEVICE INOPERATIVE REPAIR
#39136404M
Apr 1, 2025
IN VIOLATION
$0
Aug 22, 2024Elevators CLASS - 2
REPAIR AND RESTORE TO SERVICE.
#39122771R
Mar 25, 2025
IN VIOLATION
$0
Apr 24, 2024Elevators CLASS - 1
THIS IS THE ONLY ELEVATOR THAT SERVICE THE ENTIRED BUILDING OUT OF SERVICE. RESTORED TO SERVICE IMMEDIATELY AND CONTACT NYCDOB AT EIR@BUILDINGS.NYC.GOV FOR A COMPLETE INSPECTION.
#39112477R
Jul 2, 2024
IN VIOLATION
$0
Feb 26, 2024Elevators CLASS - 1
THIS IS THE ONLY ELEVATOR THAT SERVES THE ENTIRE BUILDING OUT OF SERVICE. RESTORED TO SERVICE IMMEDIATELY AND CONTACT NYCDOB AT EIR@BUILDINGS.NYC.GOV FOR A COMPLETE INSPECTION.
#39106903J
May 7, 2024
IN VIOLATION
$0
Nov 30, 2023Elevators CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE AND CALL THE DOB ELEVATOR DIVISION AT (212) 393-2144 FOR A RE-INSPECT
#39100375H
Jun 11, 2024
IN VIOLATION
$0
DOB (2)
IssuedViolationStatus
Apr 23, 2025ELEVATOR
UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. CEASE USE ORDER ISSUED FOR THE FOLLOWING ITEM: DAMAGE TO ELECTRONIC COMPONENTS AS A RESULT OF FLOODING.
#25-00655
DOB VIOLATION - ACTIVE
Apr 22, 2023FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2022
#10359
DOB VIOLATION - ACTIVE
DOB NOW Safety (20)
IssuedViolationStatus
Oct 2, 2026Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Report
Active
Jul 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Jul 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Jul 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Jul 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
Dec 19, 2025GHG Emissions - LL97 FTF-EN-LL97320
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Oct 2, 2023Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction
Active
Apr 22, 2023Retro-Commissioning - LL87 FTF-EN-EARCX
Active
HPD (10) · C 1 · B 0 · A 7
IssuedClassViolationCorrect by
Nov 21, 2025I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Nov 29, 2024I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
May 8, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 11, 2026
Feb 10, 2026CApt 211 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE 1st ROOM FROM EAST LOCATED AT B-ROOM 211, 2nd STORY, 3rd B-ROOM FROM NORTH AT EASTFeb 10, 2026
Jun 13, 2025A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Sep 16, 2025
Dec 4, 2024A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD.Mar 9, 2025
Dec 4, 2024A§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOXMar 9, 2025
Dec 4, 2024A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.Mar 9, 2025
Nov 12, 2020A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYFeb 15, 2021
Nov 12, 2020A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYFeb 15, 2021

Issued in the last 120 days

DateSourceWhatNow
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test ReportOpen
Aug 11, 2026ECBConstruction: FAILURE TO CERTIFY; VIOLATION NUMBER 35656652P, FILE A CERTIFICATE OF CORRECTIONOpen
Aug 11, 2026ECBConstruction: FAILURE TO CERTIFY; VIOLATION NUMBER 35656654Z, FILE A CERTIFICATE OF CORRECTIONOpen
Jul 30, 2026DOB SafetyAEUHAZ: Open
Jul 30, 2026DOB SafetyAEUHAZ: Open
Jul 30, 2026DOB SafetyAEUHAZ: Open
Jul 30, 2026DOB SafetyAEUHAZ: Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 9:35 PM ET. BBL 4004020025.

Look up another building