Manhattan · Block 857 · Lot 75 · 10016

4 East 28 Street

12 floors · 69,289 sq ft · built 1904 · class N2 · owner of record: New Latham Hotel Corp

9open violations
$6,247ECB/OATH penalties owed
1HPD class C (immediately hazardous)
166dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 45 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 69,289 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 166 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 166 days
Annual filing
Energy audit and retro-commissioning (2027) Likely applies
Local Law 87 · Calendar year 2027
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 857). Agency page

Dec 31, 2027
in 410 days
Next due 2027
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $34,800 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2028
in 462 days
No Cycle 10 report on record yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1141 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-05 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (7) · $6,247 owed
IssuedViolationHearingBalance
Jun 12, 2026Elevators CLASS - 2
CLASS 2: 1) EMERGENCY PHONE INOPERATIVE AS PER ASME A17.1/CSA B44 2.27.1. REMEDY: RESTORE TWO-WAY EMERGENCY COMMUNICATION. 2) PH FLOOR IDENTIFICATION NUMBERS (BRAILLE TAGS) MISSING AS PER ASME A17.1/CSA B44 2.2
#39192344X
Aug 20, 2026
ADMIT/IN-VIO
$0
Jun 12, 2026Construction CLASS - 1
ATOI OBSERVED THROUGH OUT BUILDING MISSING SPRINKLER CAPS & OBSTRUCTED SPRINKLER HEADS, BASEMENT STUDOR VENT ON VENT LINE PER PC 102.3 MAINTENANCE INSTALLATIONS BOTH EXISTING AND NEW AND PARTS THEREOF SHALL BE
#39192403R
Aug 20, 2026
IN VIOLATION
$1,250
Jun 25, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS, UNPERMITTED PLASTIC ACCESS PANELS WHICH ARE NOT FIRE
#39152012N
Mar 26, 2026
IN VIOLATION
$1,250
Jun 25, 2025Construction CLASS - 1
UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. OBSERVED EXCESSIVE STORAGE IN ELECTRICAL AND SPRINKLER ROOM/GAS METER ROOM. (CONSTRUCTION MATERIAL, BOXES, BAGS.) POTENTIAL FIRE HAZARD., MAINTAIN STORAGE I
#39152013P
Mar 26, 2026
IN VIOLATION
$2,500
Jun 18, 2025Elevators CLASS - 2
CLASS 2:EMERGENCY PHONE INOPERATIVE, CONNECT PHONE TO 24HRS EMERGENCY SERVICE. IN-CAR BLINDSPOT MIRROR MISSING,INSTALL MIRROR.HANDRAILS MISSING IN ELEVATOR,INSTALL HANDRAILS.
#39151471H
Aug 28, 2025
IN VIOLATION
$625
Apr 14, 2023Boilers CLASS - 2
CORRECT VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION
#39083806Z
Jun 22, 2023
STIPULATION/IN-VIO
$310
Jan 4, 2021Boilers CLASS - 2
FEDERAL FST-175 HT STEAM BOILER FTM BOILER WATER FEED LINE AND AIR TANK SEPARATOR LEAKING
#39034210R
Jul 29, 2021
IN VIOLATION
$312
DOB (4)
IssuedViolationStatus
Sep 21, 2026ELEVATOR
WATER DAMAGE. DEVICE IS RUNNING ON LIMITED INSPECTION SERVICE ONLY UNDER FULL CONTROL OF THE ELEVATOR COMPANY. RESTORE TO SERVICE. CEASE USE
#26-02248
DOB VIOLATION - ACTIVE
Sep 21, 2026ELEVATOR
CEASE USE WATER DAMAGE
#26-02249
DOB VIOLATION - ACTIVE
Jun 23, 2006ELEVATOR

#9011/165389
DOB VIOLATION - ACTIVE
Jun 23, 2006ELEVATOR

#9011/165394
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Sep 26, 2025Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
HPD (2) · C 1 · B 0 · A 1
IssuedClassViolationCorrect by
May 29, 2026CApt 1206 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ROOM LOCATED AT B-ROOM 1206, 12th STORY, 1st B-ROOM FROM EAST AT SOUTHJun 24, 2026
Jan 17, 2025AApt 1219 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1219, 12th STORY, 4th APARTMENT FROM EAST AT SOUTHApr 22, 2025

Issued in the last 120 days

DateSourceWhatNow
Sep 21, 2026DOBELEVATOR: WATER DAMAGE. DEVICE IS RUNNING ON LIMITED INSPECTION SERVICE ONLY UNDER FULL CONTROL OF THE ELEVATOR COMPANY. RESTORE TO SERVICE. CEASE USEOpen
Sep 21, 2026DOBELEVATOR: CEASE USE WATER DAMAGEOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 16, 2026, 7:03 AM ET. BBL 1008570075.