Bronx · Block 4820 · Lot 42 · 10466

3990 Bronx Boulevard

6 floors · 89 apartments · 76,806 sq ft · built 1965 · class D7 · owner of record: Parkash 3990 Llc

95open violations
$16,935ECB/OATH penalties owed
6HPD class C (immediately hazardous)
69dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 69 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 85 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 76,806 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 190 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 190 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 313 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 434 days
Next cycle year 2027
Energy audit and retro-commissioning (2030) Likely applies
Local Law 87 · Calendar year 2030
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 4820). Agency page

Dec 31, 2030
in 1530 days
Next due 2030
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-11 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (42) · $16,935 owed
IssuedViolationHearingBalance
Mar 12, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED DRYERS CONNECTED WITH NON-COMPLIANT FLEXIBLE HOSES IN VIOLATION OF RCNY 5-16. FURTHER OBSERVED A REDUNDANT PLUG CONNECTION
#39180198Z
Apr 5, 2027
DEFAULT
$6,280
Mar 12, 2026Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY AT TIME OF INSPECTION, OBSERVED AT ALL FOUR (4) EXPOSURES THAT SEVERAL FIRE-ESCAPE ACCESS WINDOWS ARE OBSTRUCTED BY INSTALLED AIR-CONDITIONING UNITS, OBSTRUCTING
#39180197R
Apr 5, 2027
DEFAULT
$6,280
Feb 17, 2026Elevators CLASS - 1
CLASS 1 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION
#39177516H
May 1, 2026
IN VIOLATION
$1,250
Aug 6, 2025Elevators CLASS - 2
CLASS 2:FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION,ELEVATOR IS NOT RESPONDING TO CALLS ( IN-CAR )TO 5TH,4TH AND BASEMENT FLOORS W
#39156224N
Sep 28, 2026
IN VIOLATION
$3,125
Jul 23, 2025Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED OBJECTS ON FIRE ESCAPE ON EXPOSURES 1, 3, AND 4. REMEDY: REMOVE OBJECTS FROM FIRE ESCAPE.
#35718252R
Jan 30, 2026
IN VIOLATION
$0
Jul 23, 2025Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR WALLS FACADE AND APPURTENANCES. OBSERVED DAMAGED MORTAR JOINTS, STEP CRACKS, CRACKED BRICKWORK, SPALLED/SPALLING BRICK WORK IN MULTIPLE LOCATIONS ON ALL EXPOSURES OF THE BUILDING. R
#35718251P
Jan 30, 2026
IN VIOLATION
$0
Jun 4, 2025Elevators CLASS - 1
RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION, DEVICE IS OUT OF ORDER, BY WAY OF CEASE USE ORDER, REMEDY; COMPLY WITH CEASE USE ORDER THEN NOTIFY THE NYCDOB FOR A RESTORE TO SERVICE RE-INSPECTION,
#39149972N
Aug 15, 2025
IN VIOLATION
$0
May 30, 2025Elevators CLASS - 1
RESPONDING TO A 311 ELEVATOR COMPLAINT,UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, FOR A CEASE USE VIOLATION, REMEDY; COMPLY TO CEASE USE ORDERS, AGG 2 VIOLATION WAS ISSUED TO RESPONDENT, NOTE RE
#39149437L
Aug 15, 2025
IN VIOLATION
$0
May 19, 2025Elevators CLASS - 1
CEASE USE ITEMS: DOOR LOCK MONITORING AND DOOR ZONE RESTRICTOR INOPERATIVE. TOTAL OF (3) CONTROLLER LINE FUSES 10AMP - A/C AND D/C ARE BYPASSED. THESE ARE SAFETY FEATURES WHICH ENSURES PASSENGER SAFETY. REMEDY:
#39148336H
Aug 1, 2025
IN VIOLATION
$0
May 1, 2025Elevators CLASS - 1
RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION THE DEVICE IS FOUND TO-BE-OUT OF SERVICE, AS PER 1RCNY 11-02, THIS DEVICE PROVIDE SERVICE IN A 6 STORY BUILDING,REMEDY. RESTORE TO SERVICE IMMEDIATELY AND
#39146690L
Jan 30, 2026
IN VIOLATION
$0
Feb 27, 2025Construction CLASS - 2
I OBSERVED A 6-STORY BUILDING WITH SWS ERECTED EXP#1-4,DURING MY INSPECTION I NOTICED SWS DOESN'T MEET BC3307.6.4.9 AVOID INTERFERENCE. ALSO AS PER SECTION 3307.6.3AREA TO BE PROTECTED. I NOTICED THAT SWS DECK
#39537378P
May 16, 2025
IN VIOLATION
$0
Jan 28, 2025Construction CLASS - 1
FAILURE TO PROVIDE OBSTRUCTED EXIT PASSAGEWAY. NOTE AT TIME OF INSPECTIONS OBSERVED MULTIPLE OBJECTS ON EXP #3 REAR FIRE ESCAPE ON VARIOUS LEVELS AT EXPOSURE #1 OBSERVED OBJECTS ON VARIOUS LEVELS THIS IS A HAZA
#35689258H
Apr 4, 2025
IN VIOLATION
$0
Jan 28, 2025Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION OBSERVED DAMAGED MORTAR JOINTS THROUGHOUT THE BUILDING FACADE MULTIPLE STEP CRACKS AT PARAPET LEVEL OBSERVED SPALLING
#35689257X
Apr 4, 2025
IN VIOLATION
$0
Jan 23, 2025Elevators CLASS - 1
: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION PER 1RCNY
#39136264J
Apr 4, 2025
IN VIOLATION
$0
Nov 14, 2024Construction CLASS - 1
UNLAWFUL ACTS.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER#35686575H REQUIRING THE INSTALLATION OF SAFETY MEASURES AND TO REPAIR DAMAGED FACADE AS PER 1RCNY 103-04 CODE AS WELL AS TO MAINTAIN EXTERIOR BUILDING A
#35686958P
Jan 31, 2025
IN VIOLATION
$0
Nov 1, 2024Elevators CLASS - 1
RESPONDING TO A 311 ELEVATOR COMPLAINT,UPON INSPECTION, CLASS 1 VIOLATION ISSUED FOR, CAR DOOR CLUTCH DEFECTIVE, ALTERED TO LOCK ON TO HOIST WAY DOOR ROLLERS TO PREVENT CAR DOOR FROM SPLIT, TO CHECK DLM. REMEDY
#39129221Y
Jan 17, 2025
IN VIOLATION
$0
Aug 19, 2024Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES.AS NOTEDAT TIME OF INSPECTION I OBSERVED ON EXPOSURES#1,2,3 & 4 AC UNITS INADEQUATELY SUPPORTED ON WINDOWSILLS AT SEVERAL WINDOWS AND FLOORS:SEVERE
#35683821K
Nov 1, 2024
IN VIOLATION
$0
Aug 19, 2024Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES. AS NOTED:-AT THE TIME OF INSPECTION I OBSERVED ON EXPOSURE #1, 2, 3 AND 4:-ACUNITS INADEQUATELY SUPPORTED ON WINDOW SILLS ON SEVERAL FLOORS. SEVERA
#35686575H
Dec 20, 2024
IN VIOLATION
$0
Jun 25, 2024Elevators CLASS - 1
RESPONDING TO A 311 ELEVATOR. UPON INSPECTION IN A SINGLE CAR BUILDING. DEVICE IS STILL UNDER CEASE USE FOR PREVIOUS VIOLATION, REMEDY; REPAIR THEN CONTACT NYCDOB FOR RESTORE TO SERVICE RE-INSPECTION.
#39117671N
Oct 18, 2024
IN VIOLATION
$0
May 21, 2024Elevators CLASS - 1
RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION ON DEVICE IN A SINGLE CAR BUILDING,CEASE USE VIOLATION ISSUED FOR, CAR DOOR RESTRICTOR ALTERED, / OVERHEAD TRACTION SHEAVE HUB BEARING WORN, / DLM NOT WOR
#39115098K
Aug 30, 2024
IN VIOLATION
$0
Jan 17, 2024Elevators CLASS - 1
5-A-10, 42-L-10, 56-L-10, 99-BB-5. 5-A-10=DOOR ZONE RESTRICT AND TAMPER WITH RENDERED INOPERATIVE BY REMOVING LOCKING PIN AND PLACE IT ON TOP OF CAR; MUST REPAIR IMMEDIATELY, THIS IS A SAFETY DEVICE THAT ENSURE
#38275510J
Apr 26, 2024
IN VIOLATION
$0
Nov 15, 2023Construction CLASS - 2
OCCUPANCY IN CONTRARY TO THAT ALLOWED BY C/O AND/OR DEPARTMENT OF BUILDING RECORD.UNOCCUPIED AND/OR ILLEGALLY CREATED ROOMS AT CELLAR WITH HALF BATHROOM,NO KITCHEN.NO 2ND MEANS OF EGRESS PROVIDED.NO VACATE WARR
#35483105N
Jun 7, 2024
IN VIOLATION
$0
Aug 16, 2023Construction CLASS - 2
AGGRAVATED II CONDITION. RESPONDENT HAS A HISTORY OF FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDERS. RESPONDENT FAILED TO COMPLY WITH THE COMMISSIONER'S ORDERS TO FILE CERTIFICATES OF CORRECTION FOR 8 OPEN EC
#39092669X
Apr 5, 2024
IN VIOLATION
$0
Jul 17, 2023Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED AT REAR OF DRYERS AT ABOVE PREMISES THE USE OF FLEXI HOSES THAT DO NOT COMPLY WITH CODE (R5-16) ALSO REDUNDANT LINE WILL PLUG CONNECTION BETWEEN G
#35656438Y
Sep 29, 2023
IN VIOLATION
$0
Jun 22, 2023Construction CLASS - 2
AT TIME OF INSPECTION I OBSERVED THAT VIOLATION NUMBERS 34478098L AND 34478099N HAVE NOT BEEN CORRECTED. IN RESULT YOU HAVE FAILED TO COMPLY WITH THE COMMISSIONERS ORDERS., FILE A CERTIFICATE OF CORRECTION
#39088935H
Sep 1, 2023
IN VIOLATION
$0
Jun 22, 2023Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR VIOLATION#32071829Z AND#32075353K/CORRECT ALL VIOLATING CONDITIONS/SUBMIT CERTIFICATE OF
#39088937L
Sep 1, 2023
IN VIOLATION
$0
Mar 30, 2023Elevators CLASS - 1
RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON ON INSPECTION OF THE DEVICE VIOLATION WAS FOUND, CEASE USE ITEM, DLM NOT WORKING, REMEDY; REPAIR THEN CONTACT NYCDOB FOR RESTORE TO SERVICE RE-INSPECTION, 2/ IN CAR
#39082648H
Jun 16, 2023
IN VIOLATION
$0
Jul 26, 2022Elevators CLASS - 1
CLASS 1 VIOLATION ISSUED DLM IMPROPERLY IN STALLED ON DEVICE. NO FIREMAN SERVICE PRESENT IN CONTROLLER, IN STALL FIREMAN SERVICE SO DLM IS IN COMPLIANCE WITH SECTION 3.10.12 OF APPENDIX K3,.........CLASS 2 VIOL
#39066737J
Sep 16, 2022
IN VIOLATION
$0
Apr 30, 2020Elevators CLASS - 1
42M5,11X10:42-M-5=NO DOOR LOCK MONITORING INSTALLED ON THIS CONTROLLERAS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY:FILE APPLICATIO
#38273390P
Jun 19, 2020
IN VIOLATION
$0
May 31, 2016Elevators CLASS - 1
02L10,05M07,21D10,30M11,97X10
#38243164J
Jul 15, 2016
IN VIOLATION
$0
May 26, 2016Construction CLASS - 2
SEC: 27-392; 27-393. FAILURE TO MAINTAIN FLR NUMBERING & STAIR LETTERING PER 27-392; 27-393. NOTED: MISSING FLR NUMBERING ALL FLRS & MISSINGSTAIR LETTERING PER 27-392; 27-393. REM: COMPLY W/ CODE.
#35195059P
Sep 23, 2016
IN VIOLATION
$0
Jun 22, 2015Boilers CLASS - 2
B254,16,22C,24B,50,50A/50B,50C,50D,50E,50F,50G,50H. 50-GAS PILOT REGU LATOR DEFECTIVE; 50A-OIL LEAK AT BURNER; 50B-OIL PUMP BELT GUARD NOT IN PLACE; 50C-CONDENSATE TANK VENT REDUCED; 50D-2"NIPPLE AND CAP RT
#32075353K
Dec 18, 2015
IN VIOLATION
$0
Nov 3, 2014Construction CLASS - 1
28-210.1 MULTIPLE DWELLING CONVERTED, MAINTAINED OR OCCUIPED W/3 OR MORE DWELLING UNITS THAN LEGALLY AUTHORIZED BY THE CERT. OF OCCUPANCY OROFFICAL RECORDS. NOTED : C.O. # 42584 INDIATES LEGALLY APPROVED FOR 89
#34922349P
Feb 27, 2015
IN VIOLATION
$0
Nov 3, 2014Construction CLASS - 2
28-212.11 VIOLATION OF CLOSURE ORDER AT TIME OF INSPECTION. CELLAR NORTHWEST APT. DOOR REMOVAL OF ACTIVE VACATE 85/2014. APT. DOOR HAS THE REMAINS OF THE VACATE STICKER SCRAPED ON THE DOOR. REMEDY: COMPLY W/ TH
#34939095P
Jan 2, 2015
IN VIOLATION
$0
Mar 9, 2014Construction CLASS - 1
OCCUPANCY IN CONTRARY TO THAT ALLOWED BY C OF O OF DOB RECORDS.OCCUPIED ILLEGAL CLASS "A"APT CREATED @ CELLAR WITH FULL BATHROOM & A KITCHEN PARTITIONS MADE UP OF WOOD/METAL STUD & SHEET ROCK/PLASTER.VACATE WAR
#35070241M
Oct 10, 2014
IN VIOLATION
$0
Feb 29, 2012Boilers CLASS - 2
B254,34A,46B,48A,50A,B. 50A- FRESH AIR INTAKE BLOCKED, 50B- IMPROPER STORAGE OF FUEL OIL IN OPEN CONTAINER. REPAIR/REPLACE ALL DEFECTIVE BOILER PARTS & FILE A C/C ATTACHED.
#32071829Z
Jun 29, 2012
IN VIOLATION
$0
Dec 19, 2011Elevators CLASS - 2
14L10,8V1,21I11,44H8,44H11,52H11,57H10,60Q3,100M7,72M7: 57;HOIST MOTORBEARINGS. 100;COMMUNCATION IN CAB.
#38219377N
Feb 3, 2012
DEFAULT
$0
Feb 11, 2009Elevators CLASS - 2
41G11.60T15.68M7.98BB5.99BB5.44H11.44H9.51H11.60Q3.24B10.29Q3.17H11.28B1.32O2.33O2.34O2.36O2.39O2.40O2.42O2.70O2.73O2.74O2.77O2.24 BSMT INDICATOR 17 BSMT
#38200564Z
Apr 3, 2009
DEFAULT
$0
Jan 5, 2007Elevators Non-Hazardous
14M07/10H10/86U05/43H08/05H11/05L10/05E10/17H10.05-CAR DOOR ROLLERS.05L10-REPAIR DOOR CLUTCH ROLLER ARM.17H10-WORN GIBSON(LL OR B)-FLOOR H/DOOR
#38163260J
Feb 23, 2007
DEFAULT
$0
Jul 29, 2005Plumbing Non-Hazardous
USE OR INSTALLATION OF PLUMBING MATERIALS OR EUIPEMENTS WHICH DO NOT COMPLY WITH RS-16 FOUND (4) COMMERICAL DRYEER WITH FLEX HOSE ON BACK OFTHEM REMEDY:REMOVE NON-COMPLYING MATERIAL OR EQUIPEMENT
#34478099N
Sep 16, 2005
DEFAULT
$0
Jul 29, 2005Plumbing Non-Hazardous
FAILURE TO PROVIDE A SYSTEM OF AUTOMATIC SPINKLERS WHERE REQUIRED FOUND (4) COMMERCIAL DRYER WITH NO SPINKLER COVERAGE OVER THEM. REMEDY:PROVIDE AUTOMATIC SPRINKLERS
#34478098L
Sep 16, 2005
DEFAULT
$0
Sep 28, 2004Elevators Non-Hazardous
14M07/57F10/10H10/17H10/67O02/68O02 57- ELIMINATE VERY HARD STOR-ROCKING- AT FLOOR STOPS 17H10-LL-LEVEL (BASEMENT)
#38149600X
Nov 19, 2004
DEFAULT
$0
DOB (12)
IssuedViolationStatus
Dec 11, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00462
DOB VIOLATION - ACTIVE
Nov 25, 2024CONSTRUCTION
PARTIAL VACATE ORDER DUE TO HAZARDOUS CONDITIONS SUCH AS BULGING PARAPET WALL, SPALLING MORTAR JOINTS, STEP CRACKING & VERTICAL BRICK CRACKS OBSERVED AT INSPECTION AT EXPOSURE 3 (EAST ELEVATION). REMEDY: VACATE ENTIRE REAR YARD/GARAGE ROOF AT EXPOSURE 3 (EAST ELEVATION) RESTRICT ACCESS TO VACATED AR
#LL21201MA
DOB VIOLATION - ACTIVE
Nov 14, 2024CONSTRUCTION
EWO:WAS OBSERVED AT MULTI LOCAT THROUGH EXP 1,2,3 & 4(W,N,E,&S.ELEV) SPALLING BRICK, DETERIORATED MOTAR JOINTS, CRACKS & STEPCRACKS ON BRIC FACADE, SPALLED BRICKS.@ EXP1 W.ELEV LOOSE BRICK VENEER & LINTEL PUSH -ING OF ANGLES AND BOWING & RUSTED.@ EXP3E.ELEV BULGING PARAP WALL & COMPROMISE FIRE ESCAP
#LL21201MA
DOB VIOLATION - ACTIVE
Jan 3, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00062
DOB VIOLATION - ACTIVE
Dec 13, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00050
DOB VIOLATION - ACTIVE
Oct 1, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
#03867
DOB VIOLATION - ACTIVE
Mar 3, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
#04406
DOB VIOLATION - ACTIVE
Mar 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
#03446
DOB VIOLATION - ACTIVE
Oct 1, 2012ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST
#02248
DOB VIOLATION - ACTIVE
May 3, 2012FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#01672
DOB VIOLATION - ACTIVE
Dec 13, 2011LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
#07000
DOB VIOLATION - ACTIVE
Dec 13, 2011ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST
#02446
DOB VIOLATION - ACTIVE
DOB NOW Safety (24)
IssuedViolationStatus
Jul 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Jul 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Dec 11, 2024AEUHAZ FTC-AEU-HAZ
Active
Jan 3, 2024AEUHAZ FTC-AEU-HAZ
Active
Dec 13, 2023AEUHAZ FTC-AEU-HAZ
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 1, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
Active
Mar 3, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
Active
Mar 31, 2014Elevators EVCAT1
Active
Oct 1, 2012Elevators EVCAT1
Active
Dec 13, 2011Elevators EVCAT1
Active
Dec 13, 2011Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
Active
HPD (18) · C 6 · B 11 · A 0
IssuedClassViolationCorrect by
Mar 20, 2014I§ 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS WEST 3 CELLAR APT. LLB (VACATE #115031)—
Oct 21, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT VESTIBULE TO 1ST STORY PUBLIC HALL , 1st STORYNov 4, 2026
Oct 21, 2025CApt 5H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 4th APARTMENT FROM SOUTH AT WESTNov 16, 2025
Oct 21, 2025BApt 5H · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ...RUBBER GASKET AT REFRIDGERATOR DOOR IN THE KITCHEN LOCATED AT APT 5H, 5th STORY, 4th APARTMENT FROM SOUTH AT WESTNov 25, 2025
Oct 21, 2025BApt 5H · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ...AT WEST WALL WINDOW FRAME IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5H, 5th STORY, 4th APARTMENT FROM SOUTH AT WESTNov 25, 2025
Apr 8, 2025BApt 6H · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT WASH BASIN IN THE BATHROOM LOCATED AT APT 6H, 6th STORY, 5th APARTMENT FROM SOUTH AT WESTMay 13, 2025
Aug 23, 2024CApt 2H · § 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL HOUSEHOLD ARTICLES ETC. IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORY, 4th APARTMENT FROM SOUTH AT WESTAug 29, 2024
Aug 16, 2024CApt 2H · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... CONSISTING OF APPROXIMATELY 18 SQUARE FEET AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 2H, 2nd STORY ORIGINAL VIOLATION 17010360 ISSUED 28-MAY-24 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVSep 11, 2024
May 30, 2024BApt 2H · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 4th APARTMENT FROM SOUTH AT WESTJul 4, 2024
May 30, 2024CApt 2H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORYJun 25, 2024
May 30, 2024BApt 2H · § 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORYJul 4, 2024
May 30, 2024BApt 2H · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... CONSISTING OF APPROXIMATELY 12 SQUARE FEET AT CEILING AND WEST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2H, 2nd STORY, 4th APARTMENT FROM SOUTH AT WESTJul 4, 2024
May 30, 2024BApt 2H · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORYJul 4, 2024
May 30, 2024BApt 2H · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... CONSISTING OF APPROXIMATELY 15 SQUARE FEET AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 4th APARTMENT FROM SOUTH AT WESTJul 4, 2024
May 30, 2024BApt 2H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 2H, 2nd STORYJul 4, 2024
May 30, 2024BApt 2H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 2H, 2nd STORY, 4th APARTMENT FROM SOUTH AT WESTJul 4, 2024
May 30, 2024BApt 2H · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 2H, 2nd STORYJul 4, 2024
May 30, 2024CApt 2H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2H, 2nd STORYJun 25, 2024

Issued in the last 120 days

DateSourceWhatNow
Oct 21, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT VESTIBULE TO 1ST STORY PUBLIC HALL , 1st STORYOpen
Jul 30, 2026DOB SafetyAEUHAZ: Open
Jul 30, 2026DOB SafetyAEUHAZ: Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 11:39 PM ET. BBL 2048200042.