1 floors · 14,950 sq ft · built 1955 · class O1 · owner of record: 3860 East Tremont Retail Owner Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 774 days | Next cycle year 2028 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jul 29, 2015 | CONSTRUCTION NYC ADMIN CODE ADD'L INFO 3860 EAST TREMONT AVE IS AN OCCUPIED 1 STORY RETAIL WITH A WOOD BOW STRING TRUST. W/IN 60 DAYS OF DATE OF VIO OWNER TO ENGAGE A NYS LIC PE EXPERIENCED W/WOOD TRUSSES TO PROBE & EVAL STRUCTURAL SOUNDNESS OF BOWSTRING.ANY DEFICIENCES T/BE IMMED SHORED RPR DRWGS T/BE FILED WIT #FEU21001JH | DOB VIOLATION - ACTIVE |
| Jul 31, 2014 | CONSTRUCTION FAIL TO COMPLY WITH COMMISSIONER'S ORDER. THIS BUILDING HAS A WOOD BOWSTRING TRUSS ROOF. THE DOB SERVED YOU A CURABLE COMMISSIONER'S ORDER (NOTICE OF VIOLATION) TO PRODUCE AN ENGINEER'S REPORT ON YOUR BUILDING. NO ENGINEER'S REPORT HAS BEEN RECEIVED. COMPLY WITH THE COMMISSIONER'S ORDER #FEU21006CM | DOB VIOLATION - ACTIVE |
| May 22, 2014 | CONSTRUCTION OCCUPIED 1 STORY RETAIL BUILDING W/WOOD BOWSTRING TRUSS.WITHIN 60 DAYS OF DATE OF VIOLATION OWNER TO ENGAGE A NYS LICENSED PE EXPERIENCE W/WOOD TRUSSES TO PROBE AND EVALUATE STRUCTURAL SOUNDNESS OF BOWSTRING USING FIELD VERIFICATIONS,CALCULATIONS,PROBES ETC.EACH TRUSS & BEARING TO BE EVALUATED.ANY D #FEU21002JH | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 10) | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 18, 2026, 11:08 PM ET. BBL 2055610170.