4 floors · 3 apartments · 6,900 sq ft · built 1910 · class S9 · owner of record: 383 8th Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 64 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 64 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 64 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-07-19 (Accepted). Agency page | Dec 31, 2026 in 64 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 80 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 13, 2020 | Construction CLASS - 2 SEC. 28-105.1 ILLEGAL ADVERTISING. NOTE: AT TIME OF INSPECTION I OBSERVED CONTRACTING FENCE IN PLACE W/ADVERTISEMENTS ALL OVER IT. REMEDY: COMPLY W/CODE-REMOVE ADVERTISEMENTS. #35456447J | Sep 10, 2020 DEFAULT | $6,250 |
| Nov 27, 2018 | Construction CLASS - 2 FAILURE TO POST PERMIT FOR WORK AT PREMISES. EXPIRED PERMITS POSTED 03/08/18. REM: POST PERMIT. #35373146M | Jan 24, 2019 DEFAULT | $3,125 |
| Sep 17, 2012 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. DEFECTS NOTED: AT TIME OF INSPECTION VERTICAL CRACKS & STEP CRACKS OBSERVED AT EXPOSURE #2. PARAPET WALL AT EXPOSURE #4 IS LEANING OUT OF PLUMB TOWARDS #34993333Z | Dec 20, 2012 WRITTEN OFF | $0 |
| Sep 16, 2012 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. DEFECTS: VERTICAL &STEP CRACKS AT SOUTH WALL BETWEEN 1 STY AND 2 STY MISSING BRICK WORK BETWEEN 1 STY & 2 STY AT CENTER SOUTH WALL BELOW FIRE ESCAPE, MISSING #34952077H | Dec 20, 2012 WRITTEN OFF | $0 |
| Jul 21, 2010 | Construction CLASS - 1 FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNERS. NOTED: THE FOLLOWING CONDITIONS THE BLDG HAS LEANING STEPS THRU OUT THE PUBLIC HALL CRACKEDPLASTER WALLS & CEILINGS THRU OUT THE PUBLIC HALL THE CELLAR HALL HAS #34852153M | Sep 9, 2010 DEFAULT | $0 |
| Aug 22, 1988 | Construction Unknown WORK WITHOUT A PERMIT. REMEDY: REMOVE AWNING OR OBTAIN A PERMIT AND APPROVALS FROM THIS DEPT. #34010450H | Oct 13, 1988 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 1, 2018 | CONSTRUCTION FAILURE TO MAINTAIN ADEQUATE ILLUMINATION SIDWALK SHED AS REQUIRED BY CODE. REMEDY: COMPLY WITH CODE #LLFJF02 | DOB VIOLATION - ACTIVE |
| Mar 9, 2017 | CONSTRUCTION DUE TO TRRACTOR TRAILER STRUCK 10' OF SIDEWALK SHED #CER04FC | DOB VIOLATION - ACTIVE |
| Apr 26, 1994 | ZONING #MTF2LE | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 4) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 16, 2015 | B | SECTION 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT CEILING LIGHT FIXTURE AT PUBLIC HALL, 2nd STORY | Feb 20, 2015 |
| Jul 16, 2012 | B | SECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS AT 2ND STY BALCONY,FRONT SOUTH AT FIRE ESCAPE | Aug 20, 2012 |
| Jul 16, 2012 | B | SECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITIONER PROTRUDING BEYOND WINDOW SILL AT 3RD STY BALCONY,FRONT SOUTH AT FIRE ESCAPE | Aug 20, 2012 |
| Dec 12, 2006 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING A MINUMIN OF 100 WATTS REQUIRED | Jan 21, 2007 |
| Jul 3, 2006 | A | SECTION 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER WEST OF BLDG AT FIRE ESCAPE | Oct 13, 2006 |