6 floors · 60 apartments · 64,800 sq ft · built 1927 · class D1 · owner of record: Calper Realty Associates Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 65 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 65 days | Annual |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-13 (Accepted). Agency page | Dec 31, 2026 in 65 days | 2 of 3 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 81 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 64,800 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3271). Agency page | Dec 31, 2031 in 1891 days | Next due 2031 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 12, 2026 | Unknown CLASS - 2 ATOI, OBSERVED EXPIRE PERMIT FOR TEMP CONSTRUCTION EQUIP/INSTALLATION ON SITE (SHED). PERMIT NUMBER: X01177262-I1-SH EXPIRED ON 3/05/2026., RENEW PERMIT #39200386L | Oct 16, 2026 DEFAULT | $1,280 |
| Apr 20, 2026 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7C REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #712514. AGG2 HISTORY OF NONCOMPLIANCE ON 37026 #37036433K | May 27, 2027 DEFAULT | $6,280 |
| Mar 23, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION NO ACCESS NO CERTIFICATE OF CORRECTION ON FILE WITH THE DEPARTMENT OF #39181427H | Nov 6, 2026 PENDING | $1,250 |
| Sep 23, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OF A 6-STORY BUILDING, I OBSERVED SIDEWALK SHED ERECTED EXP#1-2 WITH VALID PERMIT DURING MY INSPECTION I NOTICED SIDEWALK SHED HAS NO CONTACT INFORMATION PANEL. THIS CREATE A HAZARDOUS SIT #39545195M | Apr 10, 2026 IN VIOLATION | $1,250 |
| Sep 23, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING EXTERIOR WALL FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, OBSERVED WINDOWS SILL CRACKS BETWEEN FLOOR5-6 IN MULTI LOCATIONS AT EX. 1-WEST AND MISSING BRICK MORTAR JOINTS A #35717656Z | Apr 10, 2026 IN VIOLATION | $2,500 |
| Sep 23, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OF A 6-STORY BUILDING, I OBSERVED A SIDEWALK SHED ERECTED EXP#1-2 NOT MAINTAIN AS PER CODE 3307.6.4.10 FOUNDING AND SECTION PER CODE 3307.6.3 AREA TO PROTECT MISSING NETTING ENTRANCE TO BU #39545196Y | Apr 10, 2026 IN VIOLATION | $2,400 |
| Apr 8, 2025 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C AND 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #912514. AGG2 HISTORY OF NONCOMP #37034437Z | Jul 18, 2025 PENDING | $0 |
| Aug 26, 2024 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS#39055122J ISSUED ON 1/28/2022,AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1RCNY 102-01(D)(2).AN ACCEPTABLE CERTIFICA #37029078J | Nov 29, 2024 IN VIOLATION | $0 |
| Jul 5, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE & APPURTENANCES.NOTE:OBSERVED AT EXP #1(WEST ELE)CRACKED WINDOW SILLS ON 6TH FLOOR,A BROKEN/HANGING LIGHT FIXTURE IN ENTRANCE COURTYARD,IMPROPERLY SUPPORTED AC UNITS #35685383Z | Dec 20, 2024 IN VIOLATION | $0 |
| Apr 11, 2024 | Elevators CLASS - 1 RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTING THE A SINGLE CAR BUILDING, THE DEVICE WAS FOUND TO BE OUT OF SERVICE AS PER 1RCNY 11-02 THIS DEVICE PROVIDE SERVICE IN A 6 STORY BUILDING. REMEDY; RESTORE #39111456N | Aug 16, 2024 IN VIOLATION | $0 |
| Jan 22, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDINGS EXTERIOR FACADE AND/OR APPURTENANCES.-ATTIME OF INSPECTION I OBSERVED A STEP CRACK/DETERIORATED MORTAR JOINTS ON THE TOP FLOOR NORTH EAST CORNER OF EXPOSURE 3(EAST ELEVATION).-MISS #35674323N | Jan 21, 2025 IN VIOLATION | $0 |
| Jan 16, 2024 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7C REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28.302.5 FOR CONTROL #712514. REMEDY: FILE ACCEPTABLE REPORT. #37026788K | May 3, 2024 DEFAULT | $6,250 |
| Sep 28, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR WALLS AND APPURTENANCES. AT THE TIME OF THE INSPECTION I OBSERVED AT EXP. #1 WEST ELEVATION CRACK WINDOWS SILL,AS AT EXP. #3 AND EXP. #4 CRACK/SPALLING STUCCO. AT THE ROOF LEVEL THE #35675230Z | Dec 15, 2023 DEFAULT | $6,250 |
| Sep 7, 2023 | Construction CLASS - 2 AT TIME OF MY INSPECTION I OBSERVED A SIDEWALK SHED AT A 6 STORY BUILDING. UPON DOING REVIEWING DEPARTMENT OF BUILDING RECORDS. I NOTICED THAT PERMIT IS EXPIRED SINCE 5-10-2022 AND NO OTHER ACTIVE OR RENEWED P #39521445J | Nov 17, 2023 DEFAULT | $6,250 |
| Nov 15, 2022 | Construction CLASS - 2 I NOTICED A SIDEWALK SHED AT A 6 STORY OCCUPIED BUILDING.UPON REVIEWING DEPARTMENT OF BUILDING RECORDS I NOTICED NO VALID PERMIT ON FILE.MOST RECENT PERMIT EXPIRED 5/10/2022 PERMIT NUMBER X00104475-SH.DURATION #39509075J | Dec 30, 2022 IN VIOLATION | $0 |
| Oct 19, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#812514.AGG1:PRIOR NOV 37018161R UNDER #37023225N | Mar 3, 2023 IN VIOLATION | $3,125 |
| Aug 23, 2022 | Boilers CLASS - 1 OIL PIPING LEAK AND MESS IN BLR. RM.-FURNACE DOOR NOT CLOSING AND GASKET MISSING-NO FLAME SIGHT GLASS ON FURNACE DOOR-FRONT TUBE DOOR CORRODED-BOILER LEAKING-DEBRIS IN BLR RM-STRONG SMELL OF FUMES-SOOT ALL OVER #39068645L | Oct 7, 2022 DEFAULT | $3,125 |
| May 4, 2022 | Boilers CLASS - 2 LEAK THRU TUBE DOOR-NO CTL. PRES'TROL COVERS-HW COIL PRV DISCH. NOT PIPED-HW THERMO. DEFECT.-EXP/DEFECT. ELECT AT BURNER, OIL PUMP-DAWGS MISSING AT REAR-OIL STORED IN BLR. ROOM-BARO. DEFECT.-SAFETY VALVE DISCH. #39061523L | Aug 5, 2022 IN VIOLATION | $625 |
| Mar 10, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8; 27-371(J). NOTED: AT TIME OF INSPECTION AT 4TH FLR APT 4B - OBSERVED KEY LOCKING DEVICES INSTALLED #39057802M | Jun 3, 2022 IN VIOLATION | $625 |
| Mar 10, 2022 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED: AT TIME OF INSPECTION AT 4TH FLR APT 4B - OBSERVED LOCKING ASSEMBLIES AT TIME OF INSPECTION - INSTALLED AT RM ENTRY DOOR WHICH LEAD TO FIRE ESCAPE; OBSTRU #39057801K | Jun 3, 2022 IN VIOLATION | $1,250 |
| Mar 4, 2022 | Elevators CLASS - 2 CLASS 2 VIOLATION ISSUED NO ACCESS IN MOTOR ROOM, REMEDY; PROVIDE KEYS ON LOCATION #39057501Z | Jun 17, 2022 IN VIOLATION | $625 |
| Jan 28, 2022 | Boilers CLASS - 2 FOUND EXPOSED WIRING, CORRODED COIL PLATE, BOILER DOORS NEED TO BE RESEALED, BOLTS AND LATCHES MISSING ON DOORS, BELT GUARD MISSING AT OIL PUMP SET, REMOVE BUCKETS OF OIL FROM BOILER ROOM, POOR LIGHTING AND EXC #39055122J | Mar 18, 2022 STIPULATION/IN-VIO | $1,252 |
| Oct 14, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING FACADES/WALLS AND APPURTENANCES.AT THE TIME OF INSPECTION OBSERVED AT:EXPOSURE 2 NORTH ELEVATION:STEP CRACK AT PARAPET WALL.EXPOSURE 1 WEST ELEVATION:STEP CRACKS AT MULTIPLE LOCATIO #35577935J | Feb 4, 2022 IN VIOLATION | $0 |
| Sep 23, 2021 | Boilers CLASS - 2 FOUND EXPOSED WIRING, SMOKE ALARM ON BREECHING DEFECTIVE, WATER LEAKING FROM BOILER, CORRODED COIL PLATE, BOILER DOORS NEED TO BE RESEALED AND MISSING BOLTS ON DOORS, BELT GUARD MISSING AT PUMP SET, REMOVE ALL #39048046L | Nov 19, 2021 STIPULATION/IN-VIO | $315 |
| Nov 4, 2020 | Construction CLASS - 2 PROJECT INFORMATION PANEL SIDEWALK SHED. AT TIME OF MY INSPECTION I OBSERVED A SWS ERECTED I OBSERVED NO INFO PANEL. THIS CREATES A HAZARD SITUATION FOR FIRST RESPONDERS TO LOCATE THE ADDRESS OF BUILDING. REMED #35510402K | Jan 29, 2021 DEFAULT | $6,250 |
| Nov 4, 2020 | Construction CLASS - 2 FAILURE TO PROVIDE PEDESTRIANS PROTECTION. AT TIME OF MY INSPECTION OFA 6 STORY OCCUPIED BUILDING I OBSERVED A SIDEWALK NOT TO CODE. SIDEWALK SHED AS PER SECTION(3307.6.5) FAILURE TO MAINTAIN I NOTICED APPROX 3 #35510400R | Jan 29, 2021 DEFAULT | $10,000 |
| Nov 4, 2020 | Construction CLASS - 2 FAILURE TO PROVIDE PEDESTRIANS PROTECTION. AT TIME OF MY INSPECTION I OBSERVED A 6 STORY BUILDING OCCUPIED. I NOTICED A SIDEWALK SHED NOT TOCODE,SWS HAS (1)STORAGE AND PLACEMENT OF MATERIAL AS PER SECTION(3307. #35510401Z | Jan 29, 2021 DEFAULT | $10,000 |
| Nov 4, 2020 | Construction CLASS - 2 FAILURE TO PROVIDE PEDESTRIANS PROTECTION. AT TIME OF MY INSPECTION I OBSERVED AN OCCUPIED 6 STORY BUILDING W/ A SIDEWALK SHED ERECTED. I NOTICED SWS NOT TO CODE,SWS HAS ROTTED AND MISSING PARAPET PANELS THAT H #35499574M | Jan 29, 2021 DEFAULT | $10,000 |
| Feb 13, 2020 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#812514.REM:SUBMIT ACCEPTABLE REQUIRED #37018161R | May 1, 2020 IN VIOLATION | $1,250 |
| Mar 4, 2019 | Construction CLASS - 2 SIDEWALK SHED DOES NOT MEET CODE SPECIFICATION.AT TIME OF INSPECTION IOBSERVED A SIDEWALK SHED WAS MISSING "PARAPET" WOOD THIS CREATING HAZARDOUS CONDITION TO PUBLIC BY WOOD BOARD HIT PUBLIC & TRIPPING HAZARDOU #35403611N | Sep 27, 2019 IN VIOLATION | $2,400 |
| Nov 7, 2016 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT. AGG2 HISTORY OF NONCOMPLIANCE ON 36027688L,36017585J. REMEDY: FILE ACCEPTABLE AM #37001563Z | Mar 3, 2017 IN VIOLATION | $0 |
| May 29, 2015 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 7 REPORT TO THIS DEPT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW FISP REPORT. REMEDY: FILE AN AMENDED REPORT FOLLOWING REMEDIAL REPAIR #36027688L | Jan 29, 2016 DEFAULT | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 12, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00067 | DOB VIOLATION - ACTIVE |
| Feb 22, 2024 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 #00927 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #14216 | DOB VIOLATION - ACTIVE |
| Feb 17, 2015 | FACADE SAFETY PROGRAM #HAZ75498 | DOB VIOLATION - ACTIVE |
| Dec 31, 2013 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013 #00865 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 8) | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Sep 11, 2024 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Report | Active |
| Jun 12, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2024 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Apr 30, 2019 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019 | Active |
| Feb 17, 2015 | Facades FISP CYCLE 7C UNSAFE REPORT FILED | Active |
| Dec 31, 2013 | Facades FISPNRF FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 31, 2023 | I | §27-2153 ADM CODE THE PREMISES HAS BEEN SELECTED TO PARTICIPATE IN THE ALTERNATIVE ENFORCEMENT PROGRAM WHICH MAY RESULT IN BUILDING-WIDE INSPECTIONS, FEES, AND EXTENSIVE REPAIR WORK TO CORRECT VIOLATIONS AND UNDERLYING CONDITIONS. CHARGES FOR REPAIR WORK DONE PURSUANT TO THIS ORDER, IF NOT PAID, WIL | — |
| Sep 4, 2026 | A | Apt 1J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SINK BASE CABINET AT BOTTOM IN THE KITCHEN LOCATED AT APT 1J, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST | Dec 8, 2026 |
| Sep 4, 2026 | C | Apt 6F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Sep 30, 2026 |
| Sep 4, 2026 | C | Apt 6F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Sep 10, 2026 |
| Sep 4, 2026 | C | Apt 1J · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1J, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST | Sep 30, 2026 |
| Sep 4, 2026 | C | Apt 1J · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1J, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST | Sep 30, 2026 |
| Sep 4, 2026 | B | Apt 6F · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT SINK WASTE LINE IN THE KITCHEN LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 9, 2026 |
| Sep 4, 2026 | C | Apt 5K · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE KITCHEN LOCATED AT APT 5K, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST | Sep 30, 2026 |
| Apr 30, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 3, 2026 |
| Oct 27, 2025 | C | Apt 6H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6H, 6th STORY, 3rd APARTMENT FROM SOUTH AT WEST , 1st SECTION FROM WEST AT NORTH | Nov 2, 2025 |
| Oct 27, 2025 | C | Apt 6H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 6H, 6th STORY, 3rd APARTMENT FROM SOUTH AT WEST , 1st SECTION FROM WEST AT NORTH | Nov 2, 2025 |
| Oct 27, 2025 | A | Apt 6H · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 2nd ROOM FROM EAST, THE 3rd ROOM FROM EAST, THE 1st PRIVATE HALLWAY FROM EAST, THE KITCHEN , THE 5th ROOM FROM EAST AT NORTH LOCATED AT APT 6H, 6th STORY, 3rd APARTMENT FROM SOU | Jan 30, 2026 |
| Sep 30, 2025 | C | Apt 5E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MARBLE SADDLE AT ENTRANCE IN THE BATHROOM LOCATED AT APT 5E, 5th STORY, 3rd APARTMENT FROM NORTH AT EAST | Oct 6, 2025 |
| Sep 30, 2025 | C | Apt 5E · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK ON DOOR LEADING TO FIRESCAPE IN THE 1st ROOM FROM EAST LOCATED AT APT 5E, 5th STORY, 3rd APARTMENT FROM NORTH AT EAST | Oct 6, 2025 |
| Sep 29, 2025 | B | Apt 5E · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SEC | Nov 3, 2025 |
| Sep 29, 2025 | B | Apt 5E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WEST WALL IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' | Nov 3, 2025 |
| Sep 29, 2025 | C | Apt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' | Oct 25, 2025 |
| Sep 29, 2025 | B | Apt 5E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT EAST WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' | Nov 3, 2025 |
| Sep 29, 2025 | B | Apt 5E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE PEEPHOLE AT DOOR IN THE ENTRANCE LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' | Nov 3, 2025 |
| Sep 29, 2025 | B | Apt 5E · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTI | Nov 3, 2025 |
| Sep 25, 2025 | C | Apt 6D · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK ON DOOR LEADING TO FIRESCAPE IN THE 1st ROOM FROM EAST LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 1, 2025 |
| Sep 25, 2025 | B | Apt 5F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 30, 2025 |
| Sep 25, 2025 | C | Apt 5F · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK ON DOOR LEADING TO FIRESCAPE IN THE 1st ROOM FROM EAST LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 1, 2025 |
| Sep 25, 2025 | C | Apt 5F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 5F, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 1, 2025 |
| Sep 25, 2025 | B | Apt 6D · § 27-2070 ADM CODE DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE, ELECTRIC RANGE INSTALLED AT KITCHEN IN THE KITCHEN IN THE KITCHEN LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 30, 2025 |
| Sep 25, 2025 | C | Apt 6D · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNCAPPED GAS PIPE AT SAOUTH WALL IN THE KITCHEN LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 1, 2025 |
| Sep 25, 2025 | C | Apt 2A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK ON DOOR LEADING TO FIRESCAPE IN THE 2nd ROOM FROM EAST LOCATED AT APT 2A, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Oct 1, 2025 |
| Sep 22, 2025 | B | Apt 1E · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 1E, 1st STORY, 4th APARTMENT FROM WEST AT NORTH | Oct 27, 2025 |
| Sep 22, 2025 | B | Apt 2F · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 27, 2025 |
| Sep 22, 2025 | B | Apt 4A · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 27, 2025 |
| Aug 6, 2025 | B | Apt 1J · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 1J, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST | Sep 10, 2025 |
| Jul 30, 2025 | C | § 27-2056.4(H) AND 27-2056.17 ADM CODE -CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES. | Aug 3, 2025 |
| Jul 30, 2025 | C | § 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS. | Aug 3, 2025 |
| Feb 14, 2025 | B | Apt 1G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR MORTISE LOCK IN THE ENTRANCE LOCATED AT APT 1G, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST | Mar 21, 2025 |
| Feb 14, 2025 | C | Apt 1G · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING IN THE BATHROOM LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16088522 ISSUED 07-JUL-23 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE §27-2017.3a(5)(a) or (b). | Mar 12, 2025 |
| Feb 14, 2025 | C | Apt 1K · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AROUND THE WINDOW AT NORTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 1K, 1st STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16240602 ISSUED 18-SEP-23 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE C | Mar 12, 2025 |
| Feb 14, 2025 | B | Apt 1G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR MARBLE SADDLE IN THE ENTRANCE LOCATED AT APT 1G, 1st STORY, 2nd APARTMENT FROM NORTH AT EAST | Mar 21, 2025 |
| Feb 14, 2025 | C | Apt 6C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 12 SQ FT AT EAST WALL, BASEBOARD AT EAST WALL, WINDOW FRAME FROM NORTH AT EAST WALL, WINDOW FRAME FROM NORTH AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM EAST AT SO | Mar 12, 2025 |
| Feb 4, 2025 | C | Apt 1K · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 30 SQ FEET AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 1K, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Mar 2, 2025 |
| Nov 4, 2024 | C | Apt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 30, 2024 |
| Oct 23, 2024 | C | Apt 5C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 18, 2024 |
| Sep 20, 2024 | B | Apt 6D · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 25, 2024 |
| Aug 29, 2024 | C | Apt 6D · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES DEFECTIVE STOVE IN THE KITCHEN LOCATED AT APT 6D, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Sep 4, 2024 |
| May 17, 2024 | C | Apt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 3rd APARTMENT FROM NORTH AT EAST | Jun 12, 2024 |
| Apr 15, 2024 | B | Apt 5J · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE WATER SUPPLY PIPE AT SINK IN THE KITCHEN LOCATED AT APT 5J, 5th STORY, 5th APARTMENT FROM WEST AT NORTH | May 20, 2024 |
| Apr 15, 2024 | B | Apt 5J · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MARBLE FLOOR SADDLE IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 5th APARTMENT FROM WEST AT NORTH | May 20, 2024 |
| Apr 15, 2024 | C | Apt 5J · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, WEST WALL IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 5th APARTMENT FROM WE | May 9, 2024 |
| Apr 15, 2024 | B | Apt 5J · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER SYSTEM FROM BUILDING ENTRANCE TO APARTMENT 5J IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 5th APARTMENT FROM WEST AT NORTH | May 20, 2024 |
| Apr 15, 2024 | C | Apt 5J · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 5th APARTMENT FROM WEST AT NORTH | May 11, 2024 |
| Apr 15, 2024 | C | Apt 5J · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 5th APARTMENT FROM WEST AT NORTH | May 11, 2024 |
| Apr 15, 2024 | C | Apt 5J · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 7, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 5th APAR | May 11, 2024 |
| Apr 15, 2024 | B | Apt 5J · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 5th APARTMENT FROM WEST AT NORTH | May 20, 2024 |
| Apr 15, 2024 | B | Apt 5J · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH AT BATHTUB IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 5th APARTMENT FROM WEST AT NORTH | May 20, 2024 |
| Apr 15, 2024 | B | Apt 5J · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 5th APARTMENT FROM WEST AT NORTH | May 20, 2024 |
| Apr 15, 2024 | B | Apt 5J · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE AT CEILING LIGHT FIXTURE IN THE BATHROOM LOCATED AT APT 5J, 5th STORY, 5th APARTMENT FROM WEST AT NORTH | May 20, 2024 |
| Apr 15, 2024 | C | Apt 2G · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH A | May 9, 2024 |
| Apr 12, 2024 | C | Apt 2G · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL, EAST WALL, WEST WALL, 2nd WINDOW FRAME FROM EAST AT SOUTH WALL | May 6, 2024 |
| Apr 12, 2024 | A | Apt 2G · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st BATHROOM FROM EAST, THE FOYER LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jul 16, 2024 |
| Apr 12, 2024 | C | Apt 2G · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL, WEST WALL, 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THE 1st ROOM FROM E | May 6, 2024 |
| Apr 12, 2024 | C | Apt 2G · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) EAS | May 6, 2024 |
Showing 60 of 163. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 4, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SINK BASE CABINET AT BOTTOM IN THE KITCHEN LOCATED AT APT 1J, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST | Open |
| Sep 4, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Open |
| Sep 4, 2026 | HPD C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Open |
| Sep 4, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1J, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST | Open |
| Sep 4, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1J, 1st STORY, 3rd APARTMENT FROM SOUTH AT WEST | Open |
| Sep 4, 2026 | HPD B | § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT SINK WASTE LINE IN THE KITCHEN LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM NORTH AT EAST | Open |
| Sep 4, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE KITCHEN LOCATED AT APT 5K, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST | Open |
| Aug 12, 2026 | ECB | Unknown: ATOI, OBSERVED EXPIRE PERMIT FOR TEMP CONSTRUCTION EQUIP/INSTALLATION ON SITE (SHED). PERMIT NUMBER: X01177262-I1-SH EXPIRED ON 3/05/2026., RENEW PERMIT | Open |