6 floors · 95 apartments · 92,000 sq ft · built 1961 · class D1 · owner of record: 435 West 238 Street Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 66 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 92,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5779). Agency page | Dec 31, 2029 in 1162 days | Next due 2029 |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-11 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 27, 2026 | Construction CLASS - 1 OBSERVED IN LAUNDRY ROOM ON 1ST FLOOR DRYER VENTS NOT VENTED PROPERLY. PER BC 28-301.1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER., REPAIR AND/REPLACE #39186217M | Jul 31, 2026 DEFAULT | $6,250 |
| Apr 16, 2026 | Elevators CLASS - 1 CLASS 1 - CEASE USE: 1) FIRE FIGHTER SERVICE PHASE II INOPERATIVE - KEY ROTATES 360B0 WITHOUT ACTIVATING PHASE II AS REQUIRED BY ASME A17.1 2.27.3.2. REMEDY: REPAIR OR REPLACE PHASE II CONTROL TO RESTORE PROPER #39184828M | Jul 17, 2026 DEFAULT | $6,250 |
| Apr 16, 2026 | Elevators CLASS - 2 CLASS 2 VIOLATIONS: 1) IN-CAR HANDRAIL MISSING AS REQUIRED BY ASME A17.1 2.14.1.7. REMEDY: INSTALL HANDRAIL. 2) EMERGENCY PHONE INOPERATIVE AS REQUIRED BY ASME A17.1/CSA B44 AND 1 RCNY 3610-01. REMEDY: PROVIDE #39184827K | Jul 17, 2026 DEFAULT | $3,125 |
| Apr 16, 2026 | Unknown CLASS - 2 MISCELLANEOUS VIOLATION OF THE ELECTRICAL CODE TECHNICAL STANDARDS. OBSERVED IN THE CELLAR OUTSIDE H.W. / BOILER RM NO EMERGENCY SW LOCATED OUTSIDE THE ROOM. MUST PROVIDE SHUTDOWN NEC 230 / ASME CSD-1 OR NFPA; #39184861Y | Jul 17, 2026 DEFAULT | $4,000 |
| Apr 16, 2026 | Unknown CLASS - 1 ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED IN THE BASEMENT ON NEW PANEL INSTALLED ALSO THRU OUT BUILDING THE INSTALLATION OF NEW EXIT/ EMERGENCY LIGHTS. FOUND NO PERMIT ON FILE IN BIZ / DOB NOW. 27-3018(B), OBT #39184860M | Jul 17, 2026 DEFAULT | $12,500 |
| Issued | Violation | Status |
|---|---|---|
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #02371 | DOB VIOLATION - ACTIVE |
| Mar 26, 1990 | CONSTRUCTION #8J2 | VIOLATION UNSERVED ECB-ACTIVE |
| Aug 25, 1989 | ELEVATOR #12410801 | DOB VIOLATION - ACTIVE |
| Aug 9, 1989 | ELEVATOR (75) REPAIR HANDICAP GONG (76) REPLACE MISSING SPLICE BOX COVERS WHERE NECESSARY (77) RENEW CAR DOOR GIBBS #1445C/03 | DOB VIOLATION - ACTIVE |
| Mar 15, 1989 | ELEVATOR (15) SECURE TOP OF EXIT COVERS. (51) CLEAN CAR TOP #1119C/02 | DOB VIOLATION - ACTIVE |
| Mar 15, 1989 | ELEVATOR (15) SECURE TOP EXIT COVER. (51) REPLACE DIRECTION COVERS IN CAB (52) CLEAN CAR TOP #1119C/01 | DOB VIOLATION - ACTIVE |
| Feb 25, 1989 | ELEVATOR (51)REPLACE MISSING ELECTRICAL BOX COVERS (MOTOR ROOM) (52) INSTALL MISSING GUARD RAIL IN ELEVATOR (53)PROVIDE FAN GUARD IN ELEV #08758/4 | DOB VIOLATION - ACTIVE |
| Feb 25, 1989 | ELEVATOR (51)REPLACE MISSING ELECTRICAL BOX COVERS MOTOR ROOM (52)INSTALL HAND RAILS IN CAR #08758/3 | DOB VIOLATION - ACTIVE |
| Jan 28, 1987 | ELEVATOR #130381 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |