Brooklyn · Block 300 · Lot 17 · 11201

380 Henry Street

6 floors · 156,840 sq ft · built 1971 · class I6 · owner of record: Cobble Hill Nursinghome Inc

1open violations
$625ECB/OATH penalties owed
0HPD class C (immediately hazardous)
63dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 63 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 63 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-08-07 (Accepted). Agency page

Dec 31, 2026
in 63 days
2 of 2 without an accepted 2026 report yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 156,840 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 184 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 184 days
Annual filing
Energy audit and retro-commissioning (2030) Likely applies
Local Law 87 · Calendar year 2030
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 300). Agency page

Dec 31, 2030
in 1524 days
Next due 2030

Open violations

ECB / OATH (1) · $625 owed
IssuedViolationHearingBalance
Aug 11, 2023Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED AN ERECTED SIDEWALK SHED AT EXPOSURE 1,2&4. VERTICAL MEMBERS ARE INSTALLED ON DIRT WITHIN THE TREE PITS, GROUND SHALL BE CAPABLE OF SUPPORTING THE DESIGN LOADS OF THE SIDEWALK SH
#39520453P
Oct 18, 2023
IN VIOLATION
$625
DOB (1)
IssuedViolationStatus
Nov 17, 2025CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER AS PER SECTION 28.301.1 OF THE NYC ADMIN CODE NOTED AT THE TIME OF INSPECTION SMALL VERTICAL CRACKS THROUGHOUT ALL EXPOSURES INCLUDING VERTICAL CRACKS ON BRICK MASONRY ON BULK HEAD. WINDOW SILLS MASONRY SPALLING AND DETERIORATING AT EXPOSURE 1
#SR0601BB
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 29, 2026, 6:31 AM ET. BBL 3003000017.

Look up another building