5 floors · 6 apartments · 8,400 sq ft · built 1915 · class S9 · owner of record: Lawrence Family Properties Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1143 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-06 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 11, 2022 | Boilers CLASS - 1 OPERATING CEASE USE BLR;SPILLING@DRAFTSTAT/CHMY BASE 1/2 FULL/SMALLER FLUE NOT ABOVE LARGER FLUE@CHMY/BLR FLUE+TOP HWH FLUE PUSHED TO FAR INTO CHMY/BOTH BLR ROOMDOORS NOT CLOSE INTO FRAME;CORRECT ALL HAZARDOUS #39061851K | Oct 17, 2022 IN VIOLATION | $0 |
| Apr 12, 2022 | Boilers CLASS - 2 FOUND EXPOSED WIRING, OPENINGS ON CEILING AND WALLS, BOTH BOILER ROOM DOORS NOT CLOSING PROPERLY, EMERGENCY SHUT OFF SWITCH MISSING AT BOTH DOORS, FLUE PIPE ON GAS HW HEATERS NOT AS PER CODE AND NOT PROPERLY SU #39060033Y | Oct 17, 2022 IN VIOLATION | $0 |
| Apr 12, 2022 | Boilers CLASS - 1 CEASE USE HB SMITH SERIES 19X6 BOILER DUE TO FUMES SPILLING OUT OF BAROMETRIC DAMPER AND CLEAN OUT DOOR AT CHIMNEY BASE, DO NOT OPERATE BOILER TIL ALL HAZARDOUS CONDITIONS ARE CORRECTED AND DOB IS NOTIFIED TO R #39060032M | Oct 17, 2022 IN VIOLATION | $0 |
| Jul 28, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR IN CODE COMPLIANT MANNER. AT EAST SIDE OF ROOF,FIREPLACE CHIMENY IS LEANING AND SPALLING. UNKNOWN INTERIOR CONDITION.REMEDY:MAKE REPAIRS OR REMOVED UNUSED CHIMNEY ABOVE ROOF AND SEN #35508096Z | Oct 14, 2021 STIPULATION/IN-VIO | $0 |
| Mar 7, 2007 | Construction Non-Hazardous FAILURE TO MAINTAINED BLDG: (FIRE PLACE) DEFECT NOTED: INTERIOR BRICK WORK BECOME LOOSE & BRICKS ARE FALLING. THERE ARE NO FLU COVERS IN CHUTE & THERE (TORE) GUSTS OF COLD OUR SNOW & RAIN WATER BLOWN DOWN THE #34558475H | Oct 4, 2007 IN VIOLATION | $0 |
| Jan 17, 2007 | Construction Hazardous FAILURE TO MAINTAIN BLDG.HAZARDOUS. THE CHIMNEY & FIRE BOXES IN 3 & 4 FL HAVE BRICK USED FOR LINING FALLING INTO FIRE PLACES.REMEDY:REPAIR ALL FIRE PLACE LINING,PROVIDE TO D.O.B. CHIMNEY SMOKE TEST TO ASCERTAIN #34545472J | Oct 4, 2007 IN VIOLATION | $0 |
| Aug 11, 2006 | Construction Hazardous FAILURE TO MAINTAIN BLDG. HAZARDOUS. THE CHIMNEYS IN 3F,4F,4R HAVE BR ICKS & LINING FALLING INTO FIRE PLACES. REMEDY: REPAIR IMMEDIATELY & PROVIDE SMOKE TEST FOR ALL CHIMNEY TO THIS DEPT. #34527462R | Oct 4, 2007 IN VIOLATION | $0 |
| May 19, 2006 | Construction Non-Hazardous FAILURE TO MAINTAIN BLDG. DEFECTS NOTED:AT 3RD FLR PUBLIC HALLWAY FLR UNEVEN & SLOPING. ALSO DEFECTS @ STAIR 3RD TO 5TH FLR SLOPING TOWARD THE BANISTER & SEPARATION OF TREADS & RISERS @ 3RD FLR LANDING ENTRY #34518008M | Jul 6, 2006 STIPULATION/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 24, 1996 | CONSTRUCTION #MTF5RI | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Feb 2, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BASEMENT AT BOILER ROOM | Feb 8, 2026 |
| Feb 2, 2026 | C | Apt 3F · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 31, 2026 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 9:35 AM ET. BBL 1012710059.