1 floors · 9,800 sq ft · built 1920 · class G1 · owner of record: 3844 Ventures Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1166 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 5, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED ACTIVE WORK WITHIN THE WORK/STORAGE ZONE WHILE A STOP WORK ORDER ISSUED UNDER COMPLAINT #3A81981 WAS IN EFFECT STOPPING ALL WORK WITHIN THE WORK/STORAGE ZONE, CONTRARY TO AC 28-2 #39560163N | Dec 9, 2026 PENDING | $10,000 |
| Sep 24, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION, OBSERVED SUPPORTED SCAFFOLD NOT MAINTAINED IN A SAFE AND CODE-COMPLIANT CONDITION, WITH MISSING PINS AND GUARDRAILS, UNSECURED PLATFORM PLANKS, LOOSE AND RIPPED DEBRIS NETTING, AND PLATFO #39559593P | Dec 2, 2026 PENDING | $5,000 |
| Sep 24, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED WORK ZONE NOT MAINTAINED IN ACCORDANCE WITH THE SITE SAFETY PLAN PROVIDED ON SITE, IN THAT REQUIRED JERSEY BARRIERS SHOWN FOR THE WORK ZONE MAINTAINED/MISSING. STOP ALL USE OF WO #39559594R | Dec 2, 2026 PENDING | $2,500 |
| Sep 16, 2026 | Unknown CLASS - 2 BC 3314.1 & 3314.4.4.1 SAFE WORKING ORDER. OBSERVED SYSTEMS SCAFFOLD AT ELEVATOR SHAFT W/ MISSING TOE BOARDS AS REQUIRED IN MANUFACTURER SPECS AS WELL AS THE SCAFFOLD NOT BEING NAILED DOWN TO THE MUDSILLS IN OR #39559219P | Nov 25, 2026 PENDING | $2,500 |
| Sep 16, 2026 | Construction CLASS - 1 ATOI OBSERVED A SYSTEMS SCAFFOLD IN UNIT 1 FROM THE CELLAR TO THE 5TH FLOOR IN THE ELEVATOR SHAFT WHEN ASKED FOR SCAFFOLDING DRAWINGS NONE WERE PROVIDED THAT REFLECT THIS SYSTEMS SCAFFOLDING IN THE ELEVATOR SHA #39559218N | Nov 25, 2026 PENDING | $2,500 |
| Jul 24, 2026 | Site Safety CLASS - 1 AT TIME OF INSPECTION, OBSERVED A MAKESHIFT PLATFORM INSTALLED ON THE STAIRWAY. UPON REQUEST, REQUIRED DESIGN DRAWINGS FOR THE PLATFORM WERE NOT PROVIDED FOR INSPECTION, PREVENTING VERIFICATION THAT THE PLATFOR #39557043L | May 13, 2027 | $2,500 |
| Jul 24, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED WORKER USING A LADDER IN A MANNER CONTRARY TO THE MANUFACTURER'S SPECIFICATION, CREATING AN UNSAFE CONDITION. CONTRARY TO BC 3306.6. STOP ALL USE OF LADDERS. #39557042J | May 13, 2027 | $2,500 |
| Jul 24, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION, OBSERVED HOISTING OPERATIONS CONDUCTED WITHOUT ESTABLISHING AND MAINTAINING A CONTROLLED ACCESS ZONE BENEATH A SUSPENDED LOAD. NO TAG LINE WAS PROVIDED TO CONTROL THE LOAD WHILE BEING HOI #39557041H | May 13, 2027 | $5,000 |
| May 23, 2026 | Unknown CLASS - 2 PROPOSED 5 STORY BUILDING, FOOTPRINT (SQ. FT.)6612. OBSERVED NO CONSTRUCTION ACTIVITY TAKIN PLACE AT THE TIME OF INSPECTION. WALKED AROUND THE BUILDING AND YELLED INTO THE SITE THROUGH THE GATE. WAITED OVER 30 #39554552X | Apr 13, 2027 | $2,500 |
| May 19, 2026 | Construction CLASS - 1 INSPECTION OF A PROPOSED 5 STORIES BUILDING AT 1ST FLOOR LEVEL ACTIVE JOBSITE I OBSERVED ON MAY 18TH BY 6:15 PM WORKERS INSTALLING Q DECK, DRILLING AND GRINDING AND OTHER CONSTRUCTION ACTIVITIES ON GOING IN T #39554290P | Mar 2, 2027 PENDING | $2,500 |
| May 19, 2026 | Unknown CLASS - 1 INSPECTION OF A PROPOSED 5 STORIES BUILDING AT 1ST FLOOR LEVEL ACTIVE JOBSITE I OBSERVED ON MAY 18TH BY 6:15 PM WORKERS INSTALLING Q DECK, DRILLING AND GRINDING AND OTHER CONSTRUCTION ACTIVITIES ON THE DECK AB #39554293K | Mar 4, 2027 | $5,000 |
| May 19, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION OF A PROPOSED 5 STORIES BUILDING ACTIVE JOBSITE, I OBSERVED DEBRI CONTAINERS DUMPSTER ON THE STREET FILL TO THE BRIM WITH CONCRETE DEBRI WITHOUT BEING COVERED AS REQUIRED BC 3303.4.2 THIS #39554294M | Mar 4, 2027 | $2,500 |
| May 19, 2026 | Construction CLASS - 2 A 5 STORIES BUILDING AT 1ST FLOOR LEVEL ACTIVE JOBSITE I OBSERVED ON MAY 18TH BY 6:15 PM WORKERS INSTALLING Q DECK, DRILLING AND GRINDING AND OTHER CONSTRUCTION ACTIVITIES ON GOING IN THE LOWER FLOOR, ALL DOO #39554291R | Mar 4, 2027 | $2,500 |
| May 19, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OF A PROPOSED 5 STORIES BUILDING AT 1ST FLOOR LEVEL ACTIVE JOBSITE I OBSERVED ON MAY 18TH BY 6:15 PM WORKER USING GRINDER MACHINE FOR CUTTING. INSPECTION REVEAL THE GRINDER BLADE DOES NOT #39554292Z | Mar 4, 2027 | $2,500 |
| May 11, 2026 | Unknown CLASS - 1 INSPECTION OF A PROPOSED 5 STORIES BUILDING UNDER CONSTRUCTION I OBSERVED WORKERS ON SUPPORTED SCAFFOLD PERFORMING CONCRETE OPERATION, INSPECTION REVEALS THAT THE SCAFFOLD WAS NOT FULLY PLANKED AND NOT TIE DOW #39553992P | Nov 9, 2026 | $5,000 |
| May 11, 2026 | Unknown CLASS - 1 INSPECTION OF A PROPOSED 5 STORIES BUILDING UNDER CONSTRUCTION I OBSERVED WORKERS ON SUPPORTED SCAFFOLD PERFORMING CONCRETE OPERATION, UPON REQUEST FOR 4 HOURS SUPPORTED SCAFFOLD USER CERTIFICATION TO VERIFY CO #39553993R | Nov 9, 2026 | $5,000 |
| May 11, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION OF A PROPOSED 5 STORIES BUILDING UNDER CONSTRUCTION I OBSERVED WORKERS ON SUPPORTED SCAFFOLD PERFORMING CONCRETE OPERATION, INSPECTION REVEALS THAT THE SCAFFOLD DOES NOT HAVE GUARDRAILS T #39553991N | Nov 9, 2026 | $5,000 |
| May 11, 2026 | Unknown CLASS - 1 3307.4 A 5 STORIES BUILDING UNDER CONSTRUCTION I OBSERVED CONCRETE OPERATION IN PROGRESS WITH CONCRETE DELIVERY AND PUMP ON THE STREET AND FULL SIDEWALK CLOSURE, INSPECTION REVEAL THAT THERE WAS NO FLAG PERSON, #39553995K | Nov 9, 2026 | $5,000 |
| May 11, 2026 | Unknown CLASS - 1 TIME OF INSPECTION OF A PROPOSED 5 STORIES BUILDING UNDER CONSTRUCTION I OBSERVED SUPPORTED SCAFFOLD INSTALLED ON UNSTABLE PLATFORM AT EXPOSURE# 4, INSPECTION REVEALS THE LEGS OF THE SCAFFOLD FRAMES WAS ON OSH #39553994Z | Nov 9, 2026 | $5,000 |
| Nov 3, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED MECHANICAL DEMOLITION ON CELLAR LEVEL. REVIEW OF SSP AND APPROVED DEMO PLANS SHOWED NO MACHINE WORK AUTHORIZED. CONTRARY TO AC 28-105.12.2, UNAPPROVED MECHANICAL DEMOLITION CHANG #39546631Y | Oct 20, 2026 | $2,500 |
| Nov 3, 2025 | Unknown CLASS - 2 AT TIME OF INSPECTION, OBSERVED GENERATOR PLACED ON SIDEWALK AND STREET. UPON REVIEW OF DOT RECORDS, NO PERMIT OBTAINED FOR ITS PLACEMENT. CONTRARY TO BC 3307.2.1, OBSTRUCTION OF PUBLIC WAY WITHOUT DOT AUTHORIZ #39546632X | Oct 20, 2026 | $2,500 |
| Mar 24, 2025 | Construction CLASS - 1 AC28-323.8 AND RCNY 103-15(5). FAILURE TO SECURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING STRUCTURE AND APPURTENANCES CONFORM TO THEPROVISION OF THE ADMINISTRATIVE CODE AFTER UNSAFE NOTIFICATION FILED B #35716838P | Nov 13, 2025 DEFAULT | $10,000 |
| Apr 10, 2024 | Construction CLASS - 2 IN CELLAR LEVEL, CONCRETE SPALLING ON SEVERAL CEILING BEAMS THROUGHOUT GARAGE., REPAIR AND/OR REPLACE #39111270P | Jun 26, 2024 ADMIT/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 31, 2024 | Parking Structures FTC-PS-UNSAFE Unsafe report of parking structures filed. | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 5, 2026 | ECB | Construction: AT TIME OF INSPECTION, OBSERVED ACTIVE WORK WITHIN THE WORK/STORAGE ZONE WHILE A STOP WORK ORDER ISSUED UNDER COMPLAINT #3A81981 WAS IN EFFECT STOPPING ALL WORK WITHIN THE WORK/STORAGE ZONE, CONTRARY TO AC 28-2 | Open |
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 24, 2026 | ECB | Unknown: AT TIME OF INSPECTION, OBSERVED SUPPORTED SCAFFOLD NOT MAINTAINED IN A SAFE AND CODE-COMPLIANT CONDITION, WITH MISSING PINS AND GUARDRAILS, UNSECURED PLATFORM PLANKS, LOOSE AND RIPPED DEBRIS NETTING, AND PLATFO | Open |
| Sep 24, 2026 | ECB | Construction: AT TIME OF INSPECTION, OBSERVED WORK ZONE NOT MAINTAINED IN ACCORDANCE WITH THE SITE SAFETY PLAN PROVIDED ON SITE, IN THAT REQUIRED JERSEY BARRIERS SHOWN FOR THE WORK ZONE MAINTAINED/MISSING. STOP ALL USE OF WO | Open |
| Sep 16, 2026 | ECB | Unknown: BC 3314.1 & 3314.4.4.1 SAFE WORKING ORDER. OBSERVED SYSTEMS SCAFFOLD AT ELEVATOR SHAFT W/ MISSING TOE BOARDS AS REQUIRED IN MANUFACTURER SPECS AS WELL AS THE SCAFFOLD NOT BEING NAILED DOWN TO THE MUDSILLS IN OR | Open |
| Sep 16, 2026 | ECB | Construction: ATOI OBSERVED A SYSTEMS SCAFFOLD IN UNIT 1 FROM THE CELLAR TO THE 5TH FLOOR IN THE ELEVATOR SHAFT WHEN ASKED FOR SCAFFOLDING DRAWINGS NONE WERE PROVIDED THAT REFLECT THIS SYSTEMS SCAFFOLDING IN THE ELEVATOR SHA | Open |
| Jul 24, 2026 | ECB | Site Safety: AT TIME OF INSPECTION, OBSERVED A MAKESHIFT PLATFORM INSTALLED ON THE STAIRWAY. UPON REQUEST, REQUIRED DESIGN DRAWINGS FOR THE PLATFORM WERE NOT PROVIDED FOR INSPECTION, PREVENTING VERIFICATION THAT THE PLATFOR | Closed |
| Jul 24, 2026 | ECB | Construction: AT TIME OF INSPECTION, OBSERVED WORKER USING A LADDER IN A MANNER CONTRARY TO THE MANUFACTURER'S SPECIFICATION, CREATING AN UNSAFE CONDITION. CONTRARY TO BC 3306.6. STOP ALL USE OF LADDERS. | Closed |
| Jul 24, 2026 | ECB | Unknown: AT TIME OF INSPECTION, OBSERVED HOISTING OPERATIONS CONDUCTED WITHOUT ESTABLISHING AND MAINTAINING A CONTROLLED ACCESS ZONE BENEATH A SUSPENDED LOAD. NO TAG LINE WAS PROVIDED TO CONTROL THE LOAD WHILE BEING HOI | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 22, 2026, 2:54 PM ET. BBL 3002580131.