1 floors · 40,000 sq ft · built 1923 · class K4 · owner of record: Sherman Creek Realty
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 40,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 431 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 8, 2025 | Unknown CLASS - 1 FAILURE TO SECURE PUBLIC SAFETY AND MAKE THE BUILDING STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISION OF THE ADMINSTRATIVE CODE AFTER UNSAFE NOTIFICATION FILED BY QPSI. AS NOTED: AT THE TIME OF INSPECTION #35718385K | Dec 11, 2025 DEFAULT | $12,500 |
| Apr 6, 2025 | Unknown CLASS - 1 FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED: AT TIME OF INSPECTION ON AN ACTIVE OCCUPIED PARKING STRUCTURE CONSISTING OF 1 LEVEL OBSERVED DAMAGED BEAMS. EXPOSED SLABS, SPALLING CRACKS AND #35716619P | Sep 11, 2025 IN VIOLATION | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Aug 19, 2025 | CONSTRUCTION PARTIAL VACATE ORDER: OBSERVED LOOSE/SPALLING CONCRETE WITH EXPOSED REBARS ON THE CEILING SLAB AND HONEY COMBING OF ENCASEMENT CONCRETE AT SEVERAL LOCATIONS. THERE ARE NO SAFETY MEASURES PROVIDED. THESE UNSAFE CONDITIONS ARE CAUSING AN IMMEDIATE STRUCTURAL & SAFETY HAZARD REMEDY: VACATE ENTIRE PARKI #PS1201AE | DOB VIOLATION - ACTIVE |
| Aug 8, 2025 | CONSTRUCTION EMERGENCY WORK ORDER ON OCCUPIED PARKING STRUCTURE CONSISTING OF 1 LVL BELOW GRADE LEVEL, IN ADEQUATE/MISSING SAFETY MEASURES IN PLACE CAUSIN IMMEDIATE HAZARD TO VEHICULAR & PEDESTRIAN TRAFFIC. REMEDY: IMMEDIATELY IMPLEMENT ADEQUATE SAFETY MEASURES TO PROECT UNSAFE AREAS MEASURES MUST PREVENT ACCESS #PS1201AE | DOB VIOLATION - ACTIVE |
| Apr 6, 2025 | CONSTRUCTION EMERGENCY WORK AS NOTED ON AN OCCUPIED PARKING STRUCTURE CONSISTING OF 1 LVL DAMAGED BEAMS, EXPOSED SLABS, SPALLING CRACKS & DEFECTIVE SLAB CAUSING IMMEDIATE HAZARD TO VEHICULAR PEDS TRAFFIC REQUIRE IMMEDIATE SAFE MEAS TO BE IMPLEMENTED.REMEDY:INSTALL OF SAFE MEAS @ LVL 1 & PROV SHORING OF FAILED ST #PS1202AK | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Jan 16, 2026 | Parking Structures FTC-PS-UNSAFE unsafe report filed | Active |
| Aug 29, 2025 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Report | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 12) | Active |
| Sep 11, 2024 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Report | Active |
| Sep 11, 2024 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Report | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 2:19 PM ET. BBL 1021990001.