Bronx · Block 4649 · Lot 11 · 10467

3722 Bronx Boulevard

3 floors · 3 apartments · 5,585 sq ft · built 2006 · class C0 · owner of record: Figuereo, Kathryn

13open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 69 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 85 days
Annual
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 434 days
Next cycle year 2027

Open violations

ECB / OATH (0)

None open.

DOB (1)
IssuedViolationStatus
Jul 26, 2026CONSTRUCTION
STRUCTURE RENDERED NON COMPLIANT AT TIME OF INSPECTION DAMAGE OBSERVED TO HAVE BEEN SUSTAINED TO EXTERIOR WALL EXP.# 4 WITH CRACKS AND BOTTO M OF WALL BY DRIVEWAY THE STRUCTURE MUST BE MAINTAIN IN CODE COMPLIANT MANNER
#CER01CM
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 12)
Active
HPD (11) · C 0 · B 9 · A 2
IssuedClassViolationCorrect by
Oct 6, 2016BApt 1 · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 10, 2016
Oct 6, 2016BApt 1 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 10, 2016
Oct 6, 2016BApt 1 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR -INOPERATIVE- LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 10, 2016
Oct 6, 2016BApt 1 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). -INOPERATIVE- LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 10, 2016
Oct 6, 2016AApt 1 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE AND/OR WATER DAMAGED COUNTERTOP AT BASE CABINET IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTJan 9, 2017
Oct 6, 2016AApt 1 · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION PARTITION WALL ERECTED FROM FLOOR TO CEILING REDUCING LIGHT AND VENTILATION IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1, 1st STORY,Jan 9, 2017
Oct 6, 2016BApt 1 · § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ... IN THE ENTRANCE LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTNov 10, 2016
Aug 28, 2009BApt 1FLOO · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1FLOO, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOct 2, 2009
Sep 4, 2008B§ 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION '' AT PUBLIC HALL, 2nd STORYOct 9, 2008
Sep 3, 2008BApt 3 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE WALLS AND CEILING IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 8, 2008
Sep 3, 2008BApt 3 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE TERRACE LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 8, 2008

Issued in the last 120 days

DateSourceWhatNow
Jul 26, 2026DOBCONSTRUCTION: STRUCTURE RENDERED NON COMPLIANT AT TIME OF INSPECTION DAMAGE OBSERVED TO HAVE BEEN SUSTAINED TO EXTERIOR WALL EXP.# 4 WITH CRACKS AND BOTTO M OF WALL BY DRIVEWAY THE STRUCTURE MUST BE MAINTAIN IN CODE COMPLIANT MANNEROpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 7:57 AM ET. BBL 2046490011.