Manhattan · Block 494 · Lot 39 · 10012

37 Spring Street

5 floors · 15 apartments · 7,330 sq ft · built 1900 · class C7 · owner of record: Oritani Savings Bank

60open violations
$6,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
70dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 70 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 70 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 86 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 314 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1166 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-12 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (14) · $6,250 owed
IssuedViolationHearingBalance
Jan 15, 2021Construction CLASS - 2
EXPOSED WIRES. DEBRIS IN BOILER ROOM.HOLES IN CEILING. BOILER ROOM DOOR NOT MARKED.CORRECT VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION
#39034987X
Jul 8, 2021
DEFAULT
$6,250
Jul 14, 2012Construction CLASS - 3
WORK W/O A PERMIT-WORK NOTED: AT APT #9 FLOOR HAS BEEN RAISED ABOUT 2 INCHES THRUOUT APT & A NEW(PARTITION) INSTALLED FOR BATHROOM WALL & INSTALLED A STAND SHOWER REMOVING BATHTUB & RELOCATED TOILET (BALD) WITH
#34993101J
Aug 30, 2012
WRITTEN OFF
$0
Sep 19, 2005Construction Non-Hazardous
FAILURE TO MAINTAIN BUILDING. NOTED: CRACKED PLASTER CEILINGS IN 4TH FLOOR APT #10 & 5TH FLOOR APT #14 WITH STAINS AROUND CRACKS FROM WATERPENETRATION & BUCKLING & BULGING DOWNWARD & FLAKING PAINT. CRACKED &
#34445522K
Nov 17, 2005
WRITTEN OFF
$0
Aug 31, 2005Construction Non-Hazardous
WORK WITHOUT A PERMIT. (100% OF WORK COMPLETED) NOTED: 1 STORY, BLOCK,STORAGE FACILITY CONSTRUCTED AT REAR YARD,MEASURING APPROX 12FT X 12FTX 10FT HIGH, USED TO STORE RESTAURANT SUPPLIES. REMEDY: OBTAIN PERMITS
#34445519J
Nov 17, 2005
WRITTEN OFF
$0
Aug 31, 2005Construction Non-Hazardous
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY. NOTED: 1ST FL CONVERTED TO RESTAURANT & CELLAR CONVERTED TO KITCHEN & FOOD PREPARATION AREA FOR RESTAURANT. C O #45645 ALLOWS 1ST FL TO BE
#34445675L
Nov 17, 2005
WRITTEN OFF
$0
Aug 31, 2005Construction Non-Hazardous
OPERATION OF MECHNICAL EQUIPMENT WITHOUT AN EQUIPMENT USE PERMIT. NOTED: NO EQUIPMENT USE PERMITS FOR 5 ROOF TOP A/C UNITS MOUNTED ON DUNNAGE (AND W/O PROPER VIBRATION ABSORBTION DEVICES). WHLM005650,
#34445674J
Nov 17, 2005
WRITTEN OFF
$0
Jun 4, 2003Unknown Non-Hazardous
FAILURE TO FILE 10E / TRI UPON COMPLETION OF CONTROLLED WORK. NOTED : UNDER ALT # 102254613 A STRUCTURAL STABILITY REPORT WAS NOT FILED UPONCOMPLETION, AS REQUIRED REMEDY : FILE REGUIRED 10E / TRI
#34401187H
Nov 18, 2004
WRITTEN OFF
$0
May 5, 2003Construction Hazardous
FAILURE TO MAINTAIN BUILDING= HAZARDOUS) NOTED: THERE IS BUILDING NEAR ROOF OF EAST & WEST FACADES WITH CHIMNEY ON EAST FACADE LEANING STUCCO & (CEMENT LOATING IS FALLING OFF AND SIGNIFICANT CRACKS ON EAST & WE
#34400983Y
Jan 20, 2005
WRITTEN OFF
$0
May 5, 2003Construction Non-Hazardous
WORK W/O PERMIT NOTED: STEEL DUNNAGE INSTALLED ON ROOF PARAPET WALLS WITH (5) LARGE AC UNITS EACH APPROX 3X3X4. (4) REFREGERATOR COMPRESSORS. (1) LARGE ROOF MOUNTED EXHAUST FAN. ALL W/O APPROVED PLANS OR USE CA
#34400984X
Jan 20, 2005
WRITTEN OFF
$0
Mar 18, 2003Construction Non-Hazardous
WORK W/OUT PERMIT NOTED:A 1)STORY STRUCTURE APPROX 12'X12'X8' HIGH CONSTRUCTED OF CONCRETE BLKS WIHT STEEL DOOR AND FLAT ROOF HAS BEEN BUILTIN THE REAR YARD W/O PERMITS OR APPROVED PLANS.(STURCTURE APPEARS TO
#34381800L
May 20, 2004
WRITTEN OFF
$0
Aug 23, 2002Public Assembly Hazardous
REQUIRED MEANS OF EGRESS OBSTRUCTED : NOTED : 2 STEEL BEAMS + AC UNITS INSTALLED ON ROOF UNDER PERMIT # 102254613 EXP 6/19/03 ARE OBSTRUCTING EGRESS TO THE REAR FIRE ESCAPE REMEDY : REMOVE OBSTRUCTION PR PRO
#34336159M
Jul 15, 2004
WRITTEN OFF
$0
Jul 12, 2002Construction Non-Hazardous
WORK WITHOUT A PERMIT / EXPIRED PERMIT PERMIT #102254613-01-E NOT ISSUED 7/23/01,EXPIRED 6/19/02 REMEDY RENEW PERMIT
#34331037L
May 20, 2004
WRITTEN OFF
$0
May 23, 2002Construction Non-Hazardous
ALTERED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY AS REQUIRED BY ALT1,3 102878904 OF 05/18/00 NOTED: BUILDING CURRENTLY OCCUPIED. 2ND AND TH FL. REMEDY: OBTAIN VALID COFO.
#34316131M
May 20, 2004
WRITTEN OFF
$0
May 20, 2002Construction Non-Hazardous
WORK WITHOUT A PERMIT WORK NOTED INSTALLING A 24' DIA X 25 HORIGONTOLY X 50 VERTICALLY ON REAR OF BUILDING WITHOUT A PERMIT AND DWE FOR CHIMNEY REMEDY: STOP ALL WORK IMMEDIATELY OBTAIN PERMIT AND APPROVED PLANS
#34307425N
Jan 20, 2005
WRITTEN OFF
$0
DOB (3)
IssuedViolationStatus
Nov 8, 2019LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
#00541
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#00820
DOB VIOLATION - ACTIVE
Jun 4, 2003CONSTRUCTION

#B201MS
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 8, 2019Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
HPD (37) · C 0 · B 24 · A 13
IssuedClassViolationCorrect by
Dec 13, 2021BApt 12 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 12, 5th STORY, 1st APARTMENT FROM WEST AT NORTHJan 17, 2022
Dec 13, 2021BApt 12 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 12, 5th STORY, 1st APARTMENT FROM WEST AT NORTHJan 17, 2022
Dec 13, 2021AApt 12 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND THE ENTIRE CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 12, 5th STORY, 1st APARTMENT FROM WEST AT NORTHMar 18, 2022
Dec 13, 2021B§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CONSTRUCTION MATERIAL AT PUBLIC HALL, 1st STORYJan 17, 2022
Apr 1, 2015ASECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD.Jul 5, 2015
Oct 26, 2009ASECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE SOUTH WALL AT PUBLIC HALL STAIRS, 2nd STORYJan 29, 2010
Oct 26, 2009BSECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING ,100 WATTS INCAND. MINIMUM REQUIRED , 1st STORYNov 30, 2009
Oct 26, 2009BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT SOUTH WALL AT PUBLIC HALL STAIRS, 2nd STORYNov 30, 2009
Jun 25, 2008BD26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES 2ND STY FRONT STACK.Jul 30, 2008
Jun 25, 2008BD26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BICYCLE AT 1ST STY PUBLIC HALL.Jul 30, 2008
Jun 25, 2008BD26-10.01, 10.05 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF CHAIR AND HOUSEHOLD ITEMS AT 5TH STY PUBLIC HALL.Jul 30, 2008
Jun 25, 2008AD26-10.01 ADM CODE REFIT PUBLIC HALL BULKHEAD DOOR TO ROOF.Sep 28, 2008
Jun 25, 2008BD26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS PUBLIC HALL BULKHEAD TO ROOF.Jul 30, 2008
Jun 25, 2008AD26-10.01 ADM CODE PROVIDE APPROVED FIRE PROOF SELF CLOSING DOOR WITH KEY OPERATED DEADBOLT & LATCH SET PEEPHOLE & CHAIN DOOR GUARD AT ENTRANCE TO ALL APTS 5TH STY.Sep 28, 2008
Jun 25, 2008AD26-10.01 ADM CODE PROVIDE APPROVED FIRE PROOF SELF CLOSING DOOR WITH KEY OPERATED DEADBOLT & LATCH SET PEEPHOLE & CHAIN DOOR GUARD AT ENTRANCE TO ALL APTS 4TH STY.Sep 28, 2008
Jun 25, 2008BD26-19.07 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING NIGHT INSOECTION FIXTURES PRESENT LIGHTS NOT ON.Jul 30, 2008
Jul 28, 2006ASECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE fire retarded ceiling and walls all stories AT PUBLIC HALLNov 12, 2006
Jul 28, 2006ASECTION 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORYNov 12, 2006
Jul 28, 2006ASECTION 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYNov 12, 2006
Jul 28, 2006ASECTION 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE , YARD AT NORTHNov 12, 2006
Jul 28, 2006ASECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE masonry facia building at south all storiesNov 12, 2006
Jul 28, 2006ASECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ceramic tile walls at vestibule AT PUBLIC HALL, 1st STORYNov 12, 2006
Jul 28, 2006ASECTION 27-2005 ADM CODE REMOVE THE TORN AND/OR LOOSE FLOOR COVERING vinyl all stories AT PUBLIC HALLNov 12, 2006
Aug 26, 2003BSECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE all stories AT PUBLIC HALLOct 5, 2003
Jan 17, 2003BSECTION 53,187,231 M/D LAW & DEPT RULES & REG. PROVIDE MEANS OF EGRESS FROM YARD TO STREET BY FIREPROOF PASSAGEWAY FOR WHICH APPLICATION MUST BE FILED FOR APPROVAL,OR BY UNLOCKED DOOR OR GATE IN FENCE TO ADJOINING PREMISES WITH CONSENT OF ADJACENT OWNER. YARD AT NORTHFeb 26, 2003
Aug 29, 2002BSECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE stair tread 17 up from bottom AT PUBLIC HALL, 1st STORYOct 8, 2002
Aug 29, 2002BSECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE stair handrail AT PUBLIC HALL, 1st STORYOct 8, 2002
Aug 29, 2002BSECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. PROPERLY SECURE supports of guard rail at 5th story platform AT FIRE ESCAPE AT NORTHOct 8, 2002
Aug 29, 2002BSECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF access to fire escape obstructed by iron support beams for air conditioner units , ROOFOct 8, 2002
Aug 29, 2002BSECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. RESTORE EGRESS BY REMOVING LOCKING DEVICE AND ARRANGE TO OPEN READILY THE GATE IN FENCE AT LOT LINE ply-wood sealed YARD AT NORTHOct 8, 2002
May 22, 2002BSECTION 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF BOXES AT LOBBYJul 1, 2002
May 14, 2002BSECTION 27-2005 ADM CODE PROPERLY SECURE THE LOOSE BANISTER HANGING AT 1ST STY LANDING AT PUBLIC HALL STAIRS, 5th STORYJun 23, 2002
May 14, 2002BSECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CONSTRUCTION MATERIAL AT REAR YARD COURT, 5th STORYJun 23, 2002
May 14, 2002BSECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FLOOR 3RD AND 4TH STY LANDING AT PUBLIC HALL, 5th STORYJun 23, 2002
Apr 15, 2002BSECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT WALLS AND CEILINGS ALL STYS. AT PUBLIC HALLMay 25, 2002
Apr 15, 2002BSECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE ALL STYS. AT PUBLIC HALLMay 25, 2002
Apr 15, 2002BSECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS AT STOOPMay 25, 2002

Check the agency records