Brooklyn · Block 696 · Lot 31 · 11232

363 37 Street

4 floors · 69,260 sq ft · built 1900 · class W1 · owner of record: Nyc Department Of Education

23open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
66dto Energy audit and retro-commissioning (2026)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Energy audit and retro-commissioning (2026) Likely applies
Local Law 87 · Calendar year 2026
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 696). Agency page

Dec 31, 2026
in 66 days
Due this year
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 69,260 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1162 days
Next cycle year 2029
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-15 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (13)
IssuedViolationHearingBalance
Jun 12, 2026Construction CLASS - 2
REISSUE#35657947R FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.AT CELLAR LEVEL A STEEL CORRIDOR BEAM IS SHOWING SIGNS OF DECAY.REM:COMPLY WITH CODE.
#35734285N
Jul 15, 2026
POP/IN-VIO
$0
Jun 12, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.3RD FLOOR CORRIDOR DOORS AT STAIR C DONT CLOSE PROPERLY.STAIR A,GYM AND CAFE DOORS,B2 EXIT.REM:COMPLY WITH CODE.
#35734286P
Jul 15, 2026
POP/IN-VIO
$0
Jun 12, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NO GAS VENTS IN GAS METER ROOM.REM:COMPLY WITH CODE.
#35734287R
Jul 15, 2026
POP/IN-VIO
$0
May 2, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPIANT MANNER. NOTED: WATER DAMAGE TO WALLS AND AROUND RMS B-9, B10AND B12, B13. DAMAGE CAUSED BY REGULAR BACK UPS OF SEWER AND STORM WATER FROM PIPES AT THE PIPE CHASE BE
#35717358K
Jun 27, 2025
POP/IN-VIO
$0
May 2, 2025Construction CLASS - 2
RE-ISSUE #35689078K. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: IN THE BOILER RM AT CELLAR LEVEL, A STEEL GIRDER BEAM IS SHOWING SIGNS OF DECAY. THE CONCRETE ENCASEMENT IS CRACKED AND DETERIO
#35717357Z
Jun 27, 2025
POP/IN-VIO
$0
Sep 3, 2024Construction CLASS - 2
REISSUED ECB #3567947R. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANTMANNER. NOTED: CELLR BOILER ROOM A METAL BEAM INCASED IN CONCRETE HAS CRACKS AND SPALLING AND IS IN DANGER OF PEELING OFF AND FAILING AND IS
#35689078K
Nov 29, 2024
POP/IN-VIO
$0
Jun 5, 2023Construction CLASS - 2
REISSUE #3567947R. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT CELLAR LEVEL BEAM WITH RUNNING CRACKS AND SPALLING MASONRY ACROSS A 3FT AREA ABOVE BOILER AREA. REMEDY: REPAIR AND/OR REPLACE.
#35672947M
Nov 3, 2023
POP/IN-VIO
$0
May 28, 2021Construction CLASS - 2
REISSUE35490783H FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER.ATOINOTED@CELLAR BOILERRM MASONRY BEAM@CEILING APPROX7'X13' MASONRY CRACKED&DELAMANTING.COMPLY W/CODE.
#35561245X
Nov 3, 2021
POP/IN-VIO
$0
May 22, 2020Construction CLASS - 2
REISSUED#35447785H(8/22/19)FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER @ BOILER ROOM CELLAR LEVEL HORIZONTAL CRACKS APPROX 7'& 3' LONGON CONCRETE BEAMS. REMEDY: REPAIR &/OR REPLACE.
#35490783H
Jul 6, 2020
POP/IN-VIO
$0
Aug 22, 2019Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER NOTED AT BOILER ROOM CONCRETE BEAM WITH HORIZONTAL CRACKS APPROX 7 FT LONG AND 3FT LONG REPAIR AND/OR REPLACE
#35447785H
Jan 29, 2020
POP/IN-VIO
$0
Sep 27, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER NOTED: AT BOILER ROOM, HORIZONTAL CRACKS APPRX 7'LENGTH AND 3'LENGTH AT CENTER CONCRETE BEAM WAS OBSERVED. RMDY: REPAIR AND/OR REPLACE.
#35361734K
Jan 14, 2019
POP/IN-VIO
$0
Oct 5, 2005Boilers Non-Hazardous
50A. 50A-INSTALL A PERMANENT STAIRWAY OR INCLINED LADDER TO PERMIT SAFE ACCESS TO THE TOP OF THE BOILER AS PER NY STATE CODE (R4-4.6C) 50B-INSULATE BOILER. 50C-PIPE DOWN SAFETY VALVE DISCHARGE TO A SAFE POINT.
#32048851J
Nov 21, 2005
WRITTEN OFF
$0
Oct 5, 2005Boilers Non-Hazardous
50A/50B/50C. 50A-INSTALL A PERMANENT STAIRWAY OR INCLINED LADDER TO PERMIT SAFE ACCESS TO THE TOP OF THE BOILER AS PER NY STATE CODE (4-6.6C) 50B-INSULATE BOILER. 50C-PIPE DOWN SAFETY VALVE TO A SAFE POINT OF D
#32048742K
Nov 21, 2005
WRITTEN OFF
$0
DOB (3)
IssuedViolationStatus
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#02535
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#21410
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#21411
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 4:26 PM ET. BBL 3006960031.