Brooklyn · Block 167 · Lot 16 · 11217

362 Livingston Street

17 floors · 90 apartments · 78,630 sq ft · built 2025 · class D7 · owner of record: 372 Livingston Llc

92open violations
$158,695ECB/OATH penalties owed
22HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2025-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 44 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2023-08-04 (Accepted). Agency page

Dec 31, 2026
in 44 days
2 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 60 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 78,630 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 165 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 165 days
Annual filing
Energy audit and retro-commissioning (2027) Likely applies
Local Law 87 · Calendar year 2027
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 167). Agency page

Dec 31, 2027
in 409 days
Next due 2027
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page

Feb 21, 2028
in 461 days
No Cycle 10 report on record yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1140 days
Next cycle year 2029

Open violations

ECB / OATH (31) · $158,695 owed
IssuedViolationHearingBalance
Sep 26, 2026Unknown CLASS - 2
BC 3303.3 AT THE TIME OF MY INSPECTION OF A 24 STORY NEW BUILDING AT ROOF, BUILDING APPROXIMATELY 5745 SQUARE FEET. SITE CLOSED, NO CONSTRUCTION ACTIVITIES. UPON SHOUTING AT PERIMETER AND BANGING ON FENCE & DOO
#39559733H
Dec 2, 2026
$2,500
Sep 24, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED MULTIPLE SCAFFOLDS INSTALLED AND READY TO USE. SPIDER FRAMES HAVE TWO CROSS BRACES CONTRARY TO MANUFACTURES SPECS WHICH REQUIRE 3. ALSO OBSERVED PLATFORMS NOT CONFORMING WITH CANT
#39559609K
Dec 2, 2026
PENDING
$1,250
Sep 24, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED MULTIPLE SCAFFOLDS INSTALLED AND READY TO USE. SPIDER FRAMES HAVE TWO CROSS BRACES CONTRARY TO MANUFACTURES SPECS WHICH REQUIRE 3. ALSO OBSERVED PLATFORMS NOT CONFORMING WITH CANT
#39559596K
Dec 2, 2026
PENDING
$1,250
Sep 24, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED MULTIPLE SUSPENDED SCAFFOLDS INSTALLED AND READY TO USE. OBSERVED TIE BACKS OBSTRUCTED NOT STRAIGHT BACK. OBSERVED LIFE LINES ATTACHED TO SAME ANCHOR POINT AS THE SYSTEM USE BY OT
#39559608Z
Dec 2, 2026
PENDING
$1,250
Sep 24, 2026Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED ACTIVE SUSPENDED SCAFFOLD AT EXP. 4. UPON REVIEWING DRAWING AND COMPERING TO INSTALLATION NOTICE BOWLINES WHERE NOT IN USE FOR LIFE LINES AS PER DRAWINGS. TIEBACKS WERE NOT INSTAL
#39559595Z
Dec 2, 2026
PENDING
$2,500
Aug 18, 2026Unknown CLASS - 1
AN INCIDENT THAT OCCURRED ON 7/27/2026 AT THIS JOBSITE WHERE WORKER FELL OFF A LADDER, UPON REVIEW OF DEPARTMENTAL RECORDS IT WAS REVEALED THAT GENERAL CONTRACTOR FAILED TO SUBMIT REPORT WITHIN 3 BUSINESS DAYS
#39558063N
Oct 28, 2026
DEFAULT
$10,030
Aug 12, 2026Construction CLASS - 2
RESPONDING TO AN INCIDENT THAT 2 WORKERS WERE HIT BY FALLING OBJECTS AT THE 1ST FLOOR, INVESTIGATION REVEAL THAT 2 WORKERS WERE ON SUSPENDED SCAFFOLD AT THE 7TH FLOOR INSTALLING WINDOW FRAMING, 4 ON 7TH FLOOR B
#39557847R
Jun 22, 2027
$5,000
Aug 12, 2026Unknown CLASS - 1
AT THE TIME ON MY INSPECTION, RESPONDING TO AN INCIDENT THAT 2 WORKERS WERE HIT BY FALLING OBJECTS 1ST FLOOR, INVESTIGATION REVEAL THAT 2 WORKERS WERE ON SUSPENDED SCAFFOLD AT THE 7TH FLOOR INSTALLING WINDOW FR
#39557848Z
Jun 22, 2027
PENDING
$5,000
Jun 11, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED: AT EXPO# 1 INADEQUATE STORAGE ZONE, UNATTENDED. PLASTIC BARRIERS, CONTRARY TO SPECS, MISSING INTERLOCKING COUPLERS, NOT WATER FILLED, NO CONTINUES SOLID BARRIER UNDER SWS MECHANI
#39555381P
Jan 29, 2027
$2,400
May 12, 2026Construction CLASS - 1
RESPONDING TO AN INCIDENT THAT WORKER WAS STRUCK BY OBJECT THAT FELL FROM ELEVATOR SHAFT, INVESTIGATION REVEAL THAT A LABORER WORKING ON THE 2 FLOOR, WHEN SHE WAS PASSING BY THE ELEVATOR SHAFT AN OBJECT FELL FR
#39554050X
Feb 1, 2027
$10,000
May 12, 2026Construction CLASS - 1
RESPONDING TO AN INCIDENT THAT WORKER WAS STRUCK BY OBJECT THAT FELL FROM ELEVATOR SHAFT, INVESTIGATION REVEAL THAT A LABORER WORKING ON THE 2ND FLOOR, WHEN SHE WAS PASSING BY THE ELEVATOR SHAFT AN OBJECT FELL
#39554072R
Mar 1, 2027
$10,000
May 12, 2026Unknown CLASS - 1
BC 3301.8.2 RESPONDING TO AN INCIDENT THAT WORKER WAS STRUCK BY OBJECT THAT FELL FROM ELEVATOR SHAFT, INVESTIGATION REVEAL THAT WORKER WAS ON THE 2 FLOOR, WHILE PASSING BY THE ELEVATOR SHAFT AN OBJECT FROM THE
#39554051H
Feb 1, 2027
$5,000
May 6, 2026Construction CLASS - 2
AT THE TIME OF MY INSPECTION, RESPONDING TO AN INCIDENT THAT FEMALE WAS STRUCK ON HER LEG, INVESTIGATION REVEAL THAT SHE REPORTED THAT MATERIAL FROM A VERY TALL BUILDING FELL ON HER LEFT LEG, THE MATERIAL LS LO
#39553861P
Feb 1, 2027
$5,000
May 6, 2026Construction CLASS - 1
AT THE TIME OF MY INSPECTION, RESPONDING TO AN INCIDENT THAT FEMALE WAS STRUCK ON LEG, INVESTIGATION REVEAL THAT SITE SAFETY MANAGER WAS NOTIFY OF THE INCIDENT AT 10:00AM AND THE DEPARTMENT WAS NOTIFY AT APPROX
#39553954Y
Jan 15, 2027
$2,500
May 6, 2026Construction CLASS - 1
AT THE TIME OF MY INSPECTION, RESPONDING TO AN INCIDENT THAT FEMALE WAS STRUCK ON LEG, INVESTIGATION REVEAL THAT SITE SAFETY MANAGER WAS NOTIFY OF THE INCIDENT AT 10:00AM AND THE DEPARTMENT WAS NOTIFY AT APPROX
#39553860N
Feb 1, 2027
$5,000
May 6, 2026Construction CLASS - 1
AT THE TIME OF MY INSPECTION, RESPONDING TO AN INCIDENT THAT FEMALE WAS STRUCK ON LEG, INVESTIGATION REVEAL THAT SITE SAFETY MANAGER WAS NOTIFY OF THE INCIDENT AT 10:00AM AND THE DEPARTMENT WAS NOTIFY AT APPROX
#39553862R
Jan 15, 2027
$5,000
Mar 10, 2026Construction CLASS - 2
ON ACTIVE JOB SITE. GC-612632 WALKING FROM ROOF TO 17 FL. OBSERVED: OPEN HOLES THROUGHOUT SITE, INADEQUATE COVER, PARTIALLY COVER WITH PLYWOOD UNATTACHED TO CONCRETE SLAB, NO WARNING SIGN NO CONTROL ACCESS ZONE
#39551500K
Mar 25, 2027
DEFAULT
$5,030
Mar 10, 2026Construction CLASS - 2
ON ACTIVE JOB SITE. GC-612632 WALKING FROM ROOF TO 17 FL. OBSERVED: OPEN HOLES THROUGHOUT, INADEQUATE COVER, PARTIALLY COVER WITH PLYWOOD UNATTACHED TO CONCRETE SLAB, NO WARNING SIGN NO CONTROL ACCESS ZONE. CRE
#39551505J
Dec 3, 2026
$5,000
Jan 15, 2026Construction CLASS - 1
AT TIME OF INSPECTION, OBSERVED VERTICAL SAFETY NETTING SYSTEM LOOSE AND NOT FULLY SECURED TO FLOOR; ZERO CABLE NOT TAUT AND GAPS PRESENT ALONG DECK EDGE. CONTRARY TO BC 3308.5.STOP ALL WORK 10 FT FROM LEADING
#39549237J
Nov 2, 2026
$5,000
Jan 15, 2026Unknown CLASS - 1
AT TIME OF INSPECTION, OBSERVED WORKER ON LEADING EDGE USING SELF-RETRACTING LIFELINE, CONTRARY TO MANUFACTURER SPECIFICATIONS. CONTRARY TO BC 3301.6.1, IMPROPER EQUIPMENT USE CREATED FALL HAZARD.COMPLY WITH MA
#39549229J
Nov 2, 2026
$5,000
Jan 15, 2026Unknown CLASS - 2
AT TIME OF INSPECTION, OBSERVED WORKER STRADDLING LADDER, CONTRARY TO MANUFACTURER SPECIFICATIONS FOR EQUIPMENT. CONTRARY TO BC 3301.6.1, UNSAFE LADDER USE CREATED FALL HAZARD.COMPLY WITH MANUFACTURER SPECS. ST
#39549230R
Nov 2, 2026
$2,500
Jan 15, 2026Unknown CLASS - 1
AT TIME OF INSPECTION, OBSERVED WORKER ON LEADING EDGE USING SELF-RETRACTING LIFELINE, CONTRARY TO MANUFACTURER SPECIFICATIONS. CONTRARY TO BC 3301.6.1, IMPROPER EQUIPMENT USE CREATED FALL HAZARD.COMPLY WITH MA
#39549236H
Nov 2, 2026
$5,000
Aug 14, 2025Construction CLASS - 1
AT THE TIME OF MY INSPECTION OF A ACTIVE 24 STORY NEW BUILDING CURRENTLY AT FOUNDATION PHASE ,I OBSERVED THE CONSTRUCTION JOB SITE WAS WORKING AGAINST THE COMMISSIONER'S POSTED STOP WORK ORDER # 3A25482 ISSUED
#39543685X
Jun 17, 2027
$12,500
Aug 13, 2025Unknown CLASS - 2
BC 3307.2.1 AT TIME OF MY INSPECTION I OBSERVED SIDEWALK CLOSED AND CONSTRUCTION OPERATIONS WERE ENCROACHING ONTO ADJACENT PROPERTY AT EXPOSURE 1 UPON REVIEW OF DOT DOCUMENTS REVEAL THAT THERE WERE NO PERMITS
#39543642X
Jun 17, 2027
$5,000
Aug 13, 2025Unknown CLASS - 2
BC 3307.2.1 AT THE TIME OF MY INSPECTION OBSERVED SIDEWALK CLOSED AND CONSTRUCTION OPERATIONS WERE ENCROACHING UNTO ADJACENT PROPERTY AT EXPOSURE 1. UPON OF DOT DOCUMENTS WHICH REVEAL THERE WERE NO PERMITS FO
#39543645L
Jun 17, 2027
$5,000
Aug 13, 2025Construction CLASS - 1
AT THE TIME OF MY INSPECTION OF A NEW BUILDING UNDER CONSTRUCTION , ACTIVE JOB SITE WITH CONCRETE OPERATIONS I OBSERVED THAT THAT PEDESTRIANS PROTECTION ( BARRIERS ) / 5 FEET WIDE WALKWAY WERE NOT MAINTAINED
#39543641Y
Jun 17, 2027
$6,250
Aug 13, 2025Construction CLASS - 1
AT THE TIME OF INSPECTION DEPARTMENTAL RECORDS REVEAL THAT THERE WERE NO NOTIFICATION PROVIDED FOR THE COMMENCEMENT OF EARTHWORK AS REQUIRED , PRIOR TO THE COMMENCEMENT OF ANY EARTHWORK ON SITE THIS CREATES A
#39543643H
Nov 23, 2026
DEFAULT
$6,250
Aug 13, 2025Construction CLASS - 1
AT THE TIME OF MY INSPECTION OF A ACTIVE CONSTRUCTION JOB SITE WITH EXCAVATION AND SOIL OPERATIONS BEING DONE , DEPARTMENTAL RECORDS REVEAL NO PERMISSION WERE OBTAINED PRIOR TO EXCAVATION OPERATIONS (NOTIFICATI
#39543673Z
Jun 17, 2027
$6,250
Aug 13, 2025Construction CLASS - 2
OBSERVED 24 STORY NEW BUILDING AT EXCAVATION PHASE ACTIVE JOB SITE , ALSO OBSERVED PUBLIC BUS STOP WAS MOST RELOCATED , IDENTIFYING ON SITE SAFETY PLANS OF FREE FROM OBSTRUCTIONS AND THERE WERE INADEQUATE SAFET
#39543646N
Jun 17, 2027
$5,000
Aug 13, 2025Construction CLASS - 1
AT THE TIME OF MY INSPECTION OF A ACTIVE JOB SITE CURRENTLY AT FOUNDATION PHASE, I OBSERVED THAT THE PEDESTRIAN PROTECTION ( BARRIERS ) AND 5 FEET WIDE WALKWAY WERE NOT MAINTAINED AS PER APPROVED SAFETY PLANS.
#39543644J
Nov 23, 2026
DEFAULT
$6,250
Oct 10, 2022Construction CLASS - 1
L1- PARTIAL STOP WORK ORDER ISSUED FOR WORK WITHOUT PERMIT INTERIOR DEMO WITH 7 WORKERS AT COMMERCIAL SPACE AT GROUND FLOOR ALSO CREATING A OPENING IN MASONRY WALL BETWEEN TWO COMMERCIAL SPACES., OBTAIN PERMIT
#39071701Y
Mar 16, 2026
DEFAULT
$4,985
DOB (3)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#14954
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#14955
DOB VIOLATION - ACTIVE
Mar 27, 2007CONSTRUCTION

#02RG01
DOB VIOLATION - ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Oct 28, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 7, 2026AEUHAZ FTC-AEU-HAZ
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
HPD (79) · C 22 · B 43 · A 12
IssuedClassViolationCorrect by
Nov 19, 2025I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Nov 19, 2025I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
May 7, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 10, 2026
May 7, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 10, 2026
Sep 3, 2024A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYDec 7, 2024
Jul 16, 2024BApt 3E · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''364''Aug 20, 2024
Jul 16, 2024CApt 3E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3E, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''364''Jul 22, 2024
Jul 16, 2024BApt 3E · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 3E, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''364''Aug 20, 2024
Jul 16, 2024BApt 3E · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE AT SINK IN THE KITCHEN LOCATED AT APT 3E, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''364''Aug 20, 2024
Jul 16, 2024BApt 3E · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3E, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''364''Aug 20, 2024
Jul 16, 2024BApt 3E · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''364''Aug 20, 2024
Jul 16, 2024BApt 3E · § 27-2005 HMC: REFIT THE DOOR IN THE ENTRANCE LOCATED AT APT 3E, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''364''Aug 20, 2024
Jul 16, 2024CApt 3E · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE FRAME IN THE ENTRANCE LOCATED AT APT 3E, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''364''Jul 30, 2024
Jun 10, 2024C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOMJun 16, 2024
Jun 10, 2024CApt 3C · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 5th STORY, 1st APARTMENT FROM NORTH AT EASTJun 10, 2024
Jun 10, 2024A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1st STORYSep 13, 2024
May 17, 2023A§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES AND ALL BALCONIES AND ALL COMPONENTS AT BUILDING REAR AT FIRE ESCAPE, SECTION ''364''Aug 20, 2023
May 17, 2023C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE 100 SQ FT AT CEILING THROUGHOUT AT CELLARMay 23, 2023
May 17, 2023A§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES ALL BALCONIES AND ALL COMPONENTS AT BUILDING REAR AT FIRE ESCAPEAug 20, 2023
May 17, 2023C§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING AT CELLARMay 23, 2023
May 17, 2023A§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES ALL BALCONIES AND ALL COMPONENTS AT BUILDING FRONT AT FIRE ESCAPE, SECTION ''364''Aug 20, 2023
May 17, 2023C§ 27-2005 ADM CODE PROVIDE OPERABLE DOOR KNOB FOR RE-ENTRY AT ROOF BULKHEAD DOORMay 23, 2023
May 17, 2023B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT PUBLIC HALL, 5th STORYJun 21, 2023
May 17, 2023C§ 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE CONSTRUCTION DUST AT ALL STORIES AT PUBLIC HALLMay 23, 2023
May 17, 2023A§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STORIES ALL BALCONIES AND ALL COMPONENTS AT BUIDLING FRONT AT FIRE ESCAPEAug 20, 2023
Jul 2, 2008AD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE COPING CHIMNEY EAST ROOF.Oct 5, 2008
Jul 2, 2008BD26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES 3 STY BALCONY REAR.Aug 6, 2008
Jul 2, 2008CD26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUB HALL & BOILER ROOM DOOR.Jul 8, 2008
Jul 2, 2008CD26-11.01, 11.03, 11.05 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CELLAR THRU OUT.Jul 8, 2008
Jul 2, 2008BD26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS BOILER ROOM CELLAR.Aug 6, 2008
Jun 26, 2008CD26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUBLIC HALL & ON BOILER ROOM DOOR.Jul 2, 2008
Jun 26, 2008CApt 2E · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CASCADING WATER LEAK CEILING 1 STY WEST APT 2E CENTER ROOM ER1. , SECTION '' ''Jul 2, 2008
Jun 26, 2008AApt 2D · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW SASHES & MAKE OPERABLE 3 STY EAST APT 2D THRU OUT. , SECTION '' ''Sep 29, 2008
Jun 26, 2008BApt 2D · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 3 STY EAST APT 2D BATHROOM . , SECTION '' ''Jul 31, 2008
Jun 26, 2008CApt 2E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING 1 STY WEST APT 2E CENTER ROOM ER1. , SECTION '' ''Jul 2, 2008
Jun 26, 2008CApt 2E · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WATER PIPE UNDER WASHBASIN 1 STY WEST APT 2E BATHROOM ER1. , SECTION '' ''Jul 2, 2008
Jun 26, 2008BApt 2D · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED WATER LEAK CEILING 3 STY EAST APT 2D BATHROOM. , SECTION '' ''Jul 31, 2008
Aug 30, 2007BApt 4H · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 4 STY SOUTH APT 4H DUNHAM. LOCATED AT APT 4HOct 4, 2007
Aug 30, 2007BApt 4H · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELL & BUZZER 4 STY SOUTH APT 4H FROM 1 STY PUBLIC HALL. LOCATED AT APT 4HOct 4, 2007
Aug 30, 2007AApt 4H · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILINGS THRU OUT 4 STY SOUTH APT 4H. LOCATED AT APT 4HDec 3, 2007
Aug 30, 2007BApt 4H · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE 4 STY SOUTH APT 4H. LOCATED AT APT 4HOct 4, 2007
Aug 30, 2007B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE LINOLEUM FLOOR TILES 2 STY PUBLIC HALL.Oct 4, 2007
Aug 30, 2007BApt 3G · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 3 STY EAST APT 3G ROMAN. , SECTION '' ''Oct 4, 2007
Jun 12, 2007BApt 2F · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR ***MISSING** IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJul 22, 2007
Jun 12, 2007BApt 2F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ***CEILING AND WALLS*** IN THE KITCHEN LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJul 22, 2007
Jun 12, 2007BApt 2F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ***NORTH WALL*** IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJul 22, 2007
Jun 12, 2007CApt 2F · § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING **DOUBLE CYLINDER KEY OPERATED LOCK*** IN THE ENTRANCE LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJun 23, 2007
Jun 12, 2007BApt 2F · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJul 22, 2007
Aug 23, 2004BApt 1B · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, APARTMENT AT WESTOct 2, 2004
Aug 23, 2004BApt 1B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, APARTMENT AT WESTOct 2, 2004
Aug 23, 2004BApt 1B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH LOCATED AT APT 1B, 1st STORY, APARTMENT AT WESTOct 2, 2004
Aug 23, 2004BApt 1B · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE .... IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORYOct 2, 2004
Jul 22, 2004BApt 3F · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 4th STORY, APARTMENT AT NORTHAug 31, 2004
May 7, 2004CApt 3F · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES .. IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORY, APARTMENT AT NORTHMay 18, 2004
Mar 10, 1998BApt 2A · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL AIR VENT KITCHEN 4 STY NORTH APT 2A. , SECTION '' ''Apr 27, 1998
Mar 10, 1998AApt 2A · § 27-2043 ADM CODE PROVIDE A LOCK AND KEY TO THE ENTRANCE DOOR OF DWELLING UNIT AND, IF A CL A MULTIPLE DWELLING, ALSO CHAIN DOOR GUARD ENTRANCE DOOR 4 STY NORTH APT 2A. , SECTION '' ''Jun 26, 1998
Mar 10, 1998BApt 2A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PAINTED SPRINKLER HEAD KITCHEN 4 STY NORTH APT 2A. , SECTION '' ''Apr 27, 1998
Mar 10, 1998BApt 2A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE 4 STY NORTH APT 2A COBBS. , SECTION '' ''Apr 27, 1998
Feb 18, 1997BApt 1C · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRE CEILING SOUTHWEST ROOM 2 STY WEST APT 1C , SECTION '' ''Apr 7, 1997
Feb 18, 1997BApt 1C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILINGS THRU OUT 2 STY WEST APT 1C , SECTION '' ''Apr 7, 1997

Showing 60 of 79. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Oct 28, 2026DOB SafetyAEUHAZ: Open
Oct 7, 2026DOB SafetyAEUHAZ: Open
Sep 26, 2026ECBUnknown: BC 3303.3 AT THE TIME OF MY INSPECTION OF A 24 STORY NEW BUILDING AT ROOF, BUILDING APPROXIMATELY 5745 SQUARE FEET. SITE CLOSED, NO CONSTRUCTION ACTIVITIES. UPON SHOUTING AT PERIMETER AND BANGING ON FENCE & DOOClosed
Sep 24, 2026ECBConstruction: AT TIME OF INSPECTION OBSERVED MULTIPLE SCAFFOLDS INSTALLED AND READY TO USE. SPIDER FRAMES HAVE TWO CROSS BRACES CONTRARY TO MANUFACTURES SPECS WHICH REQUIRE 3. ALSO OBSERVED PLATFORMS NOT CONFORMING WITH CANTOpen
Sep 24, 2026ECBConstruction: AT TIME OF INSPECTION OBSERVED MULTIPLE SCAFFOLDS INSTALLED AND READY TO USE. SPIDER FRAMES HAVE TWO CROSS BRACES CONTRARY TO MANUFACTURES SPECS WHICH REQUIRE 3. ALSO OBSERVED PLATFORMS NOT CONFORMING WITH CANTOpen
Sep 24, 2026ECBConstruction: AT TIME OF INSPECTION OBSERVED MULTIPLE SUSPENDED SCAFFOLDS INSTALLED AND READY TO USE. OBSERVED TIE BACKS OBSTRUCTED NOT STRAIGHT BACK. OBSERVED LIFE LINES ATTACHED TO SAME ANCHOR POINT AS THE SYSTEM USE BY OTOpen
Sep 24, 2026ECBConstruction: AT TIME OF INSPECTION OBSERVED ACTIVE SUSPENDED SCAFFOLD AT EXP. 4. UPON REVIEWING DRAWING AND COMPERING TO INSTALLATION NOTICE BOWLINES WHERE NOT IN USE FOR LIFE LINES AS PER DRAWINGS. TIEBACKS WERE NOT INSTALOpen
Aug 18, 2026ECBUnknown: AN INCIDENT THAT OCCURRED ON 7/27/2026 AT THIS JOBSITE WHERE WORKER FELL OFF A LADDER, UPON REVIEW OF DEPARTMENTAL RECORDS IT WAS REVEALED THAT GENERAL CONTRACTOR FAILED TO SUBMIT REPORT WITHIN 3 BUSINESS DAYSOpen
Aug 12, 2026ECBConstruction: RESPONDING TO AN INCIDENT THAT 2 WORKERS WERE HIT BY FALLING OBJECTS AT THE 1ST FLOOR, INVESTIGATION REVEAL THAT 2 WORKERS WERE ON SUSPENDED SCAFFOLD AT THE 7TH FLOOR INSTALLING WINDOW FRAMING, 4 ON 7TH FLOOR BClosed
Aug 12, 2026ECBUnknown: AT THE TIME ON MY INSPECTION, RESPONDING TO AN INCIDENT THAT 2 WORKERS WERE HIT BY FALLING OBJECTS 1ST FLOOR, INVESTIGATION REVEAL THAT 2 WORKERS WERE ON SUSPENDED SCAFFOLD AT THE 7TH FLOOR INSTALLING WINDOW FROpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 3:04 PM ET. BBL 3001670016.