2 floors · 79,275 sq ft · built 1929 · class N2 · owner of record: 3600 Jerome Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 79,275 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1162 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3329). Agency page | Dec 31, 2029 in 1162 days | Next due 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-05 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 7, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. EMERGENCY LIGHTING FOR EXITS .EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1(2014 CODE)27-542:BC1008.2(2022) ATOI I OBSERVED AT THE FIRST FLOOR LEVEL I #39207100Z | Dec 18, 2026 PENDING | $1,250 |
| Oct 6, 2026 | Elevators CLASS - 2 CLASS 2: 1. DEVICE IDENTIFICATION NUMBER ON CONTROLLER DATA TAG AND MAIN LINE DISCONNECT DOES NOT MATCH DOB RECORDS, AS PER ASME A17.1 3.24.1. REMEDY: CORRECT/UPDATE DEVICE IDENTIFICATION TO MATCH DOB RECORDS. #39206960Y | Dec 18, 2026 PENDING | $625 |
| Oct 28, 2025 | Elevators CLASS - 1 CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE, EMAIL THE D.O.B. EIR@BUILDINGS.NYC.GOV. ELEVATOR DIVISION AT FOR A REINSPEC #39165132K | Jan 2, 2026 IN VIOLATION | $1,250 |
| Oct 28, 2025 | Boilers CLASS - 2 I FOUND ONE ROCKMILL MP-100 STEAM . BOILER WITH NEW FRESH AIR DUCT NOT FIRE RATED AND A FRESH AIR FAN WITH NO AIR PROVING SWITCH/ CORRECT ALL VIOLATING CONDITION/SUBMIT CERTIFICATE OF CORRECTION #39165036K | Jan 2, 2026 STIPULATION/IN-VIO | $630 |
| Oct 28, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS THROUGHOUT BUILDING. UNPERMITTED PLASTIC ACCESS (PLAST #39165149R | Jun 24, 2027 DEFAULT | $6,250 |
| Oct 28, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED EXCESSIVE LEAK ON BOILER. POTENTIAL HAZARD., REPAIR AND/OR REPLACE #39165148P | Jan 2, 2026 STIPULATION/IN-VIO | $630 |
| Oct 28, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLEGAL HARDWARE ON MECHANICAL ROOM DOOR. POTENTIAL HAZARD., REPAIR AND/OR REPLACE #39165151X | Jan 2, 2026 STIPULATION/IN-VIO | $630 |
None open.
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 7, 2026 | ECB | Construction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. EMERGENCY LIGHTING FOR EXITS .EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1(2014 CODE)27-542:BC1008.2(2022) ATOI I OBSERVED AT THE FIRST FLOOR LEVEL I | Open |
| Oct 6, 2026 | ECB | Elevators: CLASS 2: 1. DEVICE IDENTIFICATION NUMBER ON CONTROLLER DATA TAG AND MAIN LINE DISCONNECT DOES NOT MATCH DOB RECORDS, AS PER ASME A17.1 3.24.1. REMEDY: CORRECT/UPDATE DEVICE IDENTIFICATION TO MATCH DOB RECORDS. | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 4:21 PM ET. BBL 2033290085.