Bronx · Block 3329 · Lot 85 · 10467

3600 Jerome Avenue

2 floors · 79,275 sq ft · built 1929 · class N2 · owner of record: 3600 Jerome Llc

6open violations
$11,265ECB/OATH penalties owed
0HPD class C (immediately hazardous)
187dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 79,275 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1162 days
Next cycle year 2029
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3329). Agency page

Dec 31, 2029
in 1162 days
Next due 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-05 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (7) · $11,265 owed
IssuedViolationHearingBalance
Oct 7, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. EMERGENCY LIGHTING FOR EXITS .EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1(2014 CODE)27-542:BC1008.2(2022) ATOI I OBSERVED AT THE FIRST FLOOR LEVEL I
#39207100Z
Dec 18, 2026
PENDING
$1,250
Oct 6, 2026Elevators CLASS - 2
CLASS 2: 1. DEVICE IDENTIFICATION NUMBER ON CONTROLLER DATA TAG AND MAIN LINE DISCONNECT DOES NOT MATCH DOB RECORDS, AS PER ASME A17.1 3.24.1. REMEDY: CORRECT/UPDATE DEVICE IDENTIFICATION TO MATCH DOB RECORDS.
#39206960Y
Dec 18, 2026
PENDING
$625
Oct 28, 2025Elevators CLASS - 1
CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE, EMAIL THE D.O.B. EIR@BUILDINGS.NYC.GOV. ELEVATOR DIVISION AT FOR A REINSPEC
#39165132K
Jan 2, 2026
IN VIOLATION
$1,250
Oct 28, 2025Boilers CLASS - 2
I FOUND ONE ROCKMILL MP-100 STEAM . BOILER WITH NEW FRESH AIR DUCT NOT FIRE RATED AND A FRESH AIR FAN WITH NO AIR PROVING SWITCH/ CORRECT ALL VIOLATING CONDITION/SUBMIT CERTIFICATE OF CORRECTION
#39165036K
Jan 2, 2026
STIPULATION/IN-VIO
$630
Oct 28, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS THROUGHOUT BUILDING. UNPERMITTED PLASTIC ACCESS (PLAST
#39165149R
Jun 24, 2027
DEFAULT
$6,250
Oct 28, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED EXCESSIVE LEAK ON BOILER. POTENTIAL HAZARD., REPAIR AND/OR REPLACE
#39165148P
Jan 2, 2026
STIPULATION/IN-VIO
$630
Oct 28, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLEGAL HARDWARE ON MECHANICAL ROOM DOOR. POTENTIAL HAZARD., REPAIR AND/OR REPLACE
#39165151X
Jan 2, 2026
STIPULATION/IN-VIO
$630
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 7, 2026ECBConstruction: FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. EMERGENCY LIGHTING FOR EXITS .EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1(2014 CODE)27-542:BC1008.2(2022) ATOI I OBSERVED AT THE FIRST FLOOR LEVEL IOpen
Oct 6, 2026ECBElevators: CLASS 2: 1. DEVICE IDENTIFICATION NUMBER ON CONTROLLER DATA TAG AND MAIN LINE DISCONNECT DOES NOT MATCH DOB RECORDS, AS PER ASME A17.1 3.24.1. REMEDY: CORRECT/UPDATE DEVICE IDENTIFICATION TO MATCH DOB RECORDS.Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 4:21 PM ET. BBL 2033290085.