Queens · Block 355 · Lot 17 · 11106

36-05 Vernon Boulevard

4 floors · 8 apartments · 10,500 sq ft · built 1931 · class C1 · owner of record: 3605 Vernon Llc

28open violations
$0ECB/OATH penalties owed
7HPD class C (immediately hazardous)
62dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 62 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2023-05-03 (Accepted). Agency page

Dec 31, 2026
in 62 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 78 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 306 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 793 days
Next cycle year 2028

Open violations

ECB / OATH (6)
IssuedViolationHearingBalance
Mar 25, 2015Construction CLASS - 2
FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS AT JOB SITE AT TIME OF INSPECTION.NOTED: AT APT 1L,ONGOING WORK IN PROGRESS.NO APPROVED PLANS PRESENTED BY CONSTRUCTION FOREMAN, OR SUPER WHO IS ON SITE.AT APT1L APPRX
#35113427H
May 12, 2015
WRITTEN OFF
$0
Mar 25, 2015Plumbing CLASS - 1
GAS BEING SUPPLIED TO BLDG WITHOUT INSPECTION & CERTIFICATION BY DOB. I OBSERVED AT 2:30PM GAS PIPE CONNECTED TO TWO GAS HOT WATER HEATERS & RAN TO TWO NEW GAS METER BARS WITH NO GAS METER'S. HAVING NO GAS AP
#35115213L
May 26, 2015
DEFAULT
$0
Mar 25, 2015Plumbing CLASS - 1
FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED. UNDER APPL# 420997069 ONLY INSPECTION FOR GAS ROUGH THERE IS NO GAS TEST OR GAS AUTHORIZATION. THERE NO INSPECTION FOR GAS AUTHORIZATION FOR ANY GAS USAGE.
#35115218K
May 26, 2015
DEFAULT
$0
Mar 25, 2015Unknown CLASS - 2
ELECTRICAL WORK W/O PERMIT. OBSERVED AT 1:50PM NEW ELECTRICAL WORK IN STALLED IN APT 3R OUTLETS SWITCHES FIXTURES. NO APPLICATION ON FILE FOR NEW WORK APP A326565 DOES NOT COVER WORK IN APT. RMDY:OBTAIN PERMI
#35123035H
Jun 2, 2015
WRITTEN OFF
$0
Jul 31, 2014Unknown CLASS - 2
WORK W/O A PERMIT. INSPECTIONTIME 10:10AM. AT TIME OF INSPECTION I OBSERVED INSTALLATION OF NEW PIPING FOR SANITARY,WATER AND GAS USAGE ABOVE AND BELOW GRADE IN CELLAR. PHOTOS TAKEN. RMDY: OBTAIN PERMIT.
#35066707N
Sep 16, 2014
STIPULATION/IN-VIO
$0
Jul 31, 2014Unknown CLASS - 2
UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT DEVICES APPARTUS APPLICANCES MATERIALS OR WIRING IN USE. FLEX CORD USE FROM FIXTURE IN FOYER TO FIXTURE IN BEDROOM AREA IN APT 4R. REMEDY: COMPLY W/EC CODE.
#35038558K
Sep 16, 2014
WRITTEN OFF
$0
DOB (5)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#15851
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#06869
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#28191
DOB VIOLATION - ACTIVE
Jul 1, 2015FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00338
DOB VIOLATION - ACTIVE
Jul 1, 2015FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00339
DOB VIOLATION - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Jul 1, 2015AEUHAZ FTC-AEU-HAZ
Active
Jul 1, 2015AEUHAZ FTC-AEU-HAZ
Active
HPD (9) · C 7 · B 1 · A 1
IssuedClassViolationCorrect by
May 7, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 10, 2026
Mar 13, 2023CApt 3L · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE IN THE ENTRANCE LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTMar 27, 2023
Sep 16, 2022CApt 4R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM NORTH AT EASTOct 12, 2022
Sep 16, 2022CApt 4R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM NORTH AT EASTOct 12, 2022
Sep 16, 2022BApt 4R · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 6th ROOM FROM EAST LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM NORTH AT EASTOct 21, 2022
Aug 2, 2022CApt 4R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM NORTH AT EASTAug 28, 2022
Jun 16, 2021CApt 4R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM NORTH AT EASTJul 12, 2021
Jun 9, 2021CApt 4R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTHJul 5, 2021
Jun 9, 2021CApt 4R · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4R, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTHJul 5, 2021

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 8:54 AM ET. BBL 4003550017.

Look up another building