Manhattan · Block 476 · Lot 73 · 10013

356 West Broadway

2 floors · 39,000 sq ft · built 1918 · class G1 · owner of record: 360 West Broadway Property Owner Llc

16open violations
$11,080ECB/OATH penalties owed
0HPD class C (immediately hazardous)
186dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 65 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 39,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 186 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 186 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1161 days
Next cycle year 2029

Open violations

ECB / OATH (10) · $11,080 owed
IssuedViolationHearingBalance
Oct 7, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION OBSERVED: SIDEWALK SHED IN PLACE AT EXPO# 1 UNDERSIDE LIGHTING NOT ILLUMINATED AS REQUIRED BY BC 3307.6.4.8. THIS CONDITION CREATES A HAZARDOUS ENVIRONMENT FOR THE PUBLIC WALKING UNDER
#39560220K
Dec 17, 2026
PENDING
$2,400
Sep 17, 2026Construction CLASS - 2
AT THE TIME OF MY INSPECTION CONDUCTED AT APPROXIMATELY 5:00 AM IN RESPONSE TO A COMPLAINT, I OBSERVED THE UNDERSIDE OF THE SIDEWALK SHED NOT ILLUMINATED AS REQUIRED BY BC 3307.6.4.8. THIS CONDITION CREATES A H
#39559259J
Dec 3, 2026
PENDING
$2,400
Oct 10, 2025Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIO 23-02170 ISSUED ON 7/27/23. RESPONDENT HAS FAILED TO SUBMIT THE REQUIRED ENGINEERS REPORT AS OF 10/10/2025 CONCERNING STRUCTURALLY DEFICIENT CONDITIONS
#39163311R
Sep 8, 2026
DEFAULT
$6,280
Jun 11, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.OBSERVED AT EXPOSURE 1 CRACK SPALLED/SPALLING MASONRY AND BROKEN WINDOW PANE.EXPOSURE 2 DAMAGED STUCCO.EXPOSURE 3 CRACKS DETERIORATION SPALLED MASONRY AND B
#35693767H
Aug 21, 2025
ADMIT/IN-VIO
$0
Feb 19, 2025Construction CLASS - 1
FAILURE TO MAINTAIN FACADE IN A CODE-COMPLIANT MANNER. NOTED: OBSERVEDSPALLING MASONRY AT EXP 1(E. ELEV) AT MULTIPLE LOCATIONS. OBSERVED SIMILAR CONDITIONS AT EXP 3(W. ELEV) AND EXP 4(S. ELEV). AS PER PREVIOUS
#35689566J
Aug 7, 2025
ADMIT/IN-VIO
$0
Dec 13, 2024Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING FACADE IN CODE COMPLIANT MANNER.NOTE:OBSERVED AT ALL EXPOSURES SPALLING/CRACKED MASONRY AT EXPOSURE 1 EAST ELEVATION,OBSERVED SEVERAL CRACKED/MISSING GLASS WINDOWS.REM:REPAIR AND RE
#35689308R
Dec 15, 2025
ADMIT/IN-VIO
$0
Oct 19, 2024Construction CLASS - 1
FAILURE TO SECURE PUBLIC SAFETY AND MAKE THE BUILDING'S STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISIONS OF THE ADMINISTRATIVE CODE AFTER UNSAFE NOTIFICATION FILED BY QPSI. AS NOTED: AT TIME OF INSPECTION
#35686800P
Dec 26, 2024
ADMIT/IN-VIO
$0
Oct 19, 2024Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTE: AT TIME OF INSPECTION, OBSERVED AT EXPO #3(NORTH ELEV.) SPALLING CONCRETE/SPALLING STUCCO/REPAIRING MATERIAL AND RUSTED AND LOOSE STEEL PROTECTION OF
#35686801R
Dec 26, 2024
ADMIT/IN-VIO
$0
Oct 11, 2023Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION VIO23-02170, DATED 7/27/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS OF 10/11/20
#37025472J
Mar 21, 2024
IN VIOLATION
$0
Nov 9, 2013Unknown CLASS - 2
WORK W/O A PERMIT INSTALLED CAR LIFTS IN GARAGE W/NO PERMITS ON RECORD. REMEDY: OBTAIN A PERMIT.
#35028521H
Jan 30, 2014
IN VIOLATION
$0
DOB (3)
IssuedViolationStatus
Oct 24, 2024CONSTRUCTION
FULL VACATE OF ENTIRE PARKING STRUCTURE 2 STORIES PLUS CELLAR DUE TO THE IMMEDIATE HAZARDS POSED: OBSERVED IN ADEQUATE PROTECTION IN PLACE TO PROTECT THE INSTALLED SHORING POST FROM VEHICULAR IMPACT. THESE CONDITIONS HAVE THEREFORE MADE THE ENTIRE PARKING STRUCTURE UNSAFE TO BE OCCUPIED. REMEDY: VAC
#LL021AE
DOB VIOLATION - ACTIVE
Oct 19, 2024CONSTRUCTION
EMERGENCY WORK ORDER DUE TO CONCRETE SPALLING STUCCO/REPAIRING MATERIAL SPALLING, FACADE BRICK MASONRY BULGED ALSO RUSTED AND LOOSE STEEL PROTECTION OF WINDOW GLASS @ MULT. LOC EXP3 (N.ELEV). REMEDY: IMMEDIATELY TAKE & PROVIDE SAFE MEASURES TO SECURE & PROTECT PUBLIC, ALSO REMOVE /SECURE ALL LOOSE/H
#FA0201AE
DOB VIOLATION - ACTIVE
Jul 27, 2023CONSTRUCTION
FAILURE TO MAINTAIN BUILDING WALLS IN A CODE COMPLIANT MANNER. NOTED: BUILDING IN STATE OF DISREPAIR AND DETERIORATED WITH SPALLING CONCRETE THROUGHOUT, MULTIPLE VERTICAL AND HORIZONTAL CRACKS AND MISSING MASONRY COPING STONE AT ROOF LEVEL.
#23-02170
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Sep 25, 2026Benchmarking - LL84 DQ-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 2)
Active
Dec 31, 2024Parking Structures FTC-PS-UNSAFE
Unsafe report of parking structures filed.
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 7, 2026ECBConstruction: AT THE TIME OF INSPECTION OBSERVED: SIDEWALK SHED IN PLACE AT EXPO# 1 UNDERSIDE LIGHTING NOT ILLUMINATED AS REQUIRED BY BC 3307.6.4.8. THIS CONDITION CREATES A HAZARDOUS ENVIRONMENT FOR THE PUBLIC WALKING UNDEROpen
Sep 25, 2026DOB SafetyBenchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4Open
Sep 17, 2026ECBConstruction: AT THE TIME OF MY INSPECTION CONDUCTED AT APPROXIMATELY 5:00 AM IN RESPONSE TO A COMPLAINT, I OBSERVED THE UNDERSIDE OF THE SIDEWALK SHED NOT ILLUMINATED AS REQUIRED BY BC 3307.6.4.8. THIS CONDITION CREATES A HOpen
Aug 4, 2026ECBConstruction: AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE WITH AN OPERABLE LIGHTING BULBS UNDERSIDE OF SIDEWALK SHED THIS CREATES UNSAFE AND MUGGING CONDITIONS FOR PEDESTRIANPROVIDE AND MAINTAIN OPERABLE LIGHTINGClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 27, 2026, 12:12 AM ET. BBL 1004760073.