Manhattan · Block 1295 · Lot 23 · 10016

355 Lexington Avenue

22 floors · 225,000 sq ft · built 1958 · class O4 · owner of record: 355 Lexington Llc

1open violations
$27,424ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 225,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Energy audit and retro-commissioning (2035) Likely applies
Local Law 87 · Calendar year 2035
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1295). Agency page

Dec 31, 2035
in 3334 days
Next due 2035
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

On fileCycle 10 filing on record: SWARMP (2026-01-09)

Open violations

ECB / OATH (7) · $27,424 owed
IssuedViolationHearingBalance
Aug 12, 2026Unknown CLASS - 2
DURING AN INSPECTION OF AN ALTERATION AT A 22-STORY BUILDING, AN INADEQUATE SWS INFORMATION WAS OBSERVED. AT EXPOSURE #2, MISSING INFORMATION PANEL. AT EXPOSURE #1, AN INCORRECT ADDRESS WAS DISPLAYED. PROVIDE T
#39557869H
May 11, 2027
$2,500
Jun 25, 2026Unknown CLASS - 1
RESPONDING TO AN INCIDENT WHERE A WORKER WAS REMOVING INSULATION FROM THE CEILING ON THE 4TH FLOOR WITH A BAKER SCAFFOLD. INSPECTION REVEALED THAT THE 2 OF THE WHEELS WERE NOT LOCKED AND THE WORKER WAS ATTEMPTI
#39555887M
Apr 15, 2027
$5,000
Jun 25, 2026Unknown CLASS - 1
RESPONDING TO AN INCIDENT WHERE A WORKER FELL FROM A BAKER SCAFFOLD WHILE ATTEMPTING TO MOVE IT. INSPECTION REVEALED THAT THE SCAFFOLD WAS MISSING MULTIPLE PLATFORM SECURITY LATCH AND LOCKING PINS WHICH COMPROM
#39555888Y
Apr 15, 2027
$2,500
Jun 5, 2026Construction CLASS - 2
NOTE: AT TIME OF INSPECTION, I OBSERVED SIDEWALK SHED ERECTED AT EXPOURES#1-4 WITH MISSING 20 FEET EXTENSION AT BOTH EXPOSURES CONTRARY (3307.6.3). CREATING AN UNSAFE CONDITION. PROVIDE 20 FEET EXTENSIONS
#39555119J
Mar 18, 2027
$2,400
Jun 5, 2026Site Safety CLASS - 1
NOTE: AT TIME OF INSPECTION OF A 23-STORY BUILDING WITH ACTIVE INTERIOR DEMOLITION OPERATIONS, I OBSERVED THAT THE DEMOLITION WORK BEING DONE IS MORE THAN 50 PERCENT OF THE GROSS FLOOR AREA, UPON REVIEWING THE
#39555115M
Mar 18, 2027
$10,000
Jun 5, 2026Construction CLASS - 1
RESPONDING TO AN INCIDENT WHERE A WORKER WHERE REMOVING CEILING TILES ON THE 5 FLOOR WHEN THE LIGHT FIXTURE FELL HITTING HIM ON HIS LEFT SHOULDERS. INSPECTION ALSO REVEAL THAT THERE WERE NO SEQUENCE OF OPERATIO
#39555118H
Mar 18, 2027
$5,000
Nov 15, 2019Construction CLASS - 2
AC 27-929.1, FAILURE TO COMPLETE THE INSTALLATION OF A FULL SYSTEM OF AUTOMATIC SPRINKLERS & FILE SPRINKLER REPORT PREPARED BY A REGISTERD DESIGN PROFESSIONAL BY JULY 1, 2019, IN AN OFFICE BUILDING 100 FEET OR
#37016620H
Feb 20, 2020
DEFAULT
$24
DOB (1)
IssuedViolationStatus
Dec 12, 2007ELEVATOR

#9444/230182
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Aug 12, 2026ECBUnknown: DURING AN INSPECTION OF AN ALTERATION AT A 22-STORY BUILDING, AN INADEQUATE SWS INFORMATION WAS OBSERVED. AT EXPOSURE #2, MISSING INFORMATION PANEL. AT EXPOSURE #1, AN INCORRECT ADDRESS WAS DISPLAYED. PROVIDE TClosed

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 9:30 AM ET. BBL 1012950023.