Bronx · Block 5531 · Lot 103 · 10465

3546 East Tremont Avenue

1 floors · 5,772 sq ft · built 2025 · class K1 · owner of record: Lam Li Realty Llc

0open violations
$52,620ECB/OATH penalties owed
0HPD class C (immediately hazardous)
774dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 774 days
Next cycle year 2028

Open violations

ECB / OATH (12) · $52,620 owed
IssuedViolationHearingBalance
Aug 15, 2025Unknown CLASS - 1
3303.4.4.3-OBSERVED INADEQUATE HOUSEKEEPING THROUGHOUT JOBSITE. INTERIOR OF JOBSITE HAS LARGE AMOUNTS OF TRASH AND DEBRIS THROUGHOUT, REAR YARD LARGE ABUNDANCE OF MATERIAL STORAGE AND DEBRIS. SECOND FLOOR OF SI
#39543721Y
Dec 4, 2026
$5,000
Aug 15, 2025Construction CLASS - 1
OBSERVED ACTIVE 2 STORY JOBSITE WITH STRUCTURAL STEEL CONNECTIONS AND CONCRETE DECK. SECOND FLOOR WORK DECK W/OUT GUARDRAILS INSTALLED AT THE PERIMETER, NO CAZ NOT , TIE POINTS FOR FALLS PROTECTION. STOP ALL WO
#39543727P
Dec 4, 2026
$5,000
Aug 15, 2025Unknown CLASS - 1
3305.3.5.2-OBSERVED AN ACTIVE 2-STORY JOBSITE WITH STRUCTURAL STEEL CONNECTIONS AND CONCRETE DECK AT 2ND FL W/ DECK IS LARGE AMOUNT OF MATERIALS & DEBRIS SCATTERED. UPON REQUEST FOR LOADS REPORT TO VERIFY THE L
#39543716J
Dec 4, 2026
$5,000
Aug 15, 2025Construction CLASS - 1
OBSERVED ACTIVE CONSTRUCTION OPERATIONS ON A 2-STORY BUILDING W/ MAKE-SHIFT STRUCTURAL ELEMENTS, TORCHED & MODIFIED CONNECTION PLATES, NO PROPER CONNECTIONS ON I-BEAMS. UPON REVIEW OF PROVIDED DOB APPROVED PLAN
#39543715H
Mar 5, 2027
$2,530
Aug 15, 2025Construction CLASS - 2
3301.2-OBSERVED SIDEWALK SHED AT EXPOSURE 1 OF JOBSITE, APPROXIMATELY 12 FT IN HEIGHT IN CLOSE PROXIMITY OF POWERLINES AND RUNNING THROUGH SHED. FAILURE TO PROTECT POWERLINES CREATES A DETRIMENTAL WORKING AREA
#39543729Z
Mar 5, 2027
$5,030
Aug 15, 2025Unknown CLASS - 2
3301.6-OBSERVED MAKESHIFT PULLY SYSTEM INSTALLED ON 2ND FLOOR OF JOBSITE. MAKE SHIFT CONNECTION COMPOSE OF LOSE MEMBER & SAND BAGS FIR COUNTER WEIGHTS. UPON REQUEST FOR DESIGN DRAWINGS FOR THE EQUIPMENT, NONE W
#39543728R
Mar 5, 2027
$2,530
Aug 15, 2025Unknown CLASS - 1
3305.2.2-AT TIME OF INSPECTION ON AN ACTIVE JOBSITE, OBSERVED STEEL ASSEMBLY/ FABRICATION/ CONNECTION/ MODIFIEDÂ FROM 1ST TO 2ND FL. UPON REQUEST FOR APPROVED PE SHOP DRAWINGS AND SPECIAL INSPECTIONS BY THE AG
#39543714X
Mar 5, 2027
$5,030
Aug 15, 2025Unknown CLASS - 2
OBSERVED JOBSITE W/ MULTIPLE VIOLATING CONDITIONS CONSISTING OF NO GUARDRAILS, MAKESHIFT STEEL CONNECTION, POWERLINE W/OUT PROTECTION. CS 27048 MADE NO ATTEMPT TO CORRECT UNSAFE CONDITIONS AND MADE NOT LOGS ENT
#39543730X
Dec 4, 2026
$5,000
Aug 15, 2025Unknown CLASS - 1
3301.6-OBSERVED MAKESHIFT SUPPORTED PIPE SCAFFOLDING APPROX 24 FT IN HEIGHT, INSTALLED AT EXPO 1 OF JOBSITE USED FOR EGRESS TO ACCESS 2ND FL. SCAFFOLD RESTING ON SOIL AND ACCESS LADDER ON BRICK, MISSING PIN CON
#39543720M
Dec 4, 2026
$5,000
Aug 15, 2025Unknown CLASS - 2
OBSERVED WORKERS ON ACTIVE JOBSITE USING SUPPORTED SCAFFOLD SYSTEM. UPON REQUEST FOR REQUIRED WORKERS WALLET TO VERIFY IF THEY HAD ADEQUATE TRAINING, 2 WORKERS ( YIZHI YU & QINGSHENG FU) DID NOT HAVE THEM AT TI
#39543722X
Dec 4, 2026
$2,500
Apr 14, 2025Unknown CLASS - 1
BC 3301.1.1 RESPONSIBILITY FOR SAFETY. ACTIVE JOBSITE UNDER EARTHWORK & FOUNDATION, I OBSERVED USE OF EXCAVATOR MACHINERY FOR LOADING & LEVELLING OPERATION CLOSE TO SIDEWALK EXPOSURE 1. UPON REQUEST OF OPERATOR
#39539085K
Aug 25, 2026
IN VIOLATION
$5,000
Apr 14, 2025Unknown CLASS - 1
SAFE MEANS OF EXCAVATION- ACTIVE JOBSITE UNDER EARTHWORK & FOUNDATION STAGE. I OBSERVED WORKERS PERFORMING WORK IN OPEN EXCAVATION OF APPROXIMATELY MORE THAN 12FEET DEEP WITH AT LEAST NO ONE SAFE MEANS OF INGRE
#39539088X
Aug 25, 2026
IN VIOLATION
$5,000
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 5:24 PM ET. BBL 2055310103.

Look up another building