Bronx · Block 3344 · Lot 102 · 10467

3535 Kings College Place

6 floors · 120 apartments · 160,000 sq ft · built 1954 · class D4 · owner of record: College Gardens Co Op Inc

110open violations
$161,865ECB/OATH penalties owed
1HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 46 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 46 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 62 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 160,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 167 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 167 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1142 days
Next cycle year 2029
Energy audit and retro-commissioning (2034) Likely applies
Local Law 87 · Calendar year 2034
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3344). Agency page

Dec 31, 2034
in 2968 days
Next due 2034
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-11 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (23) · $161,865 owed
IssuedViolationHearingBalance
Oct 29, 2026Elevators CLASS - 1
CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE, AS PER ASME A17.1-2013 8.6.4.13.1, AS MODIFIED BY NYC APPENDIX K. REPAIR AND EMAIL EIR@BUILDINGS.NYC.GOV FOR RE-INSPECTION. CLASS 2 ITEMS: DEBRIS PRESENT ON CAR
#39209936H
Jan 15, 2027
PENDING
$1,250
Jul 27, 2026Construction CLASS - 2
PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTED AT THE TIME OF INSPECTION I OBSERVED DEFECTIVE/INADEQUATE AND DAMAGED/ROTTED MUDSILLS AT MULTIPLE LOCATIONS WHICH ARE NOT IN COMPLIANCE WITH NYC AD
#35729922K
Oct 2, 2026
DEFAULT
$2,430
May 11, 2026Elevators CLASS - 1
RTS CLASS 1: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION
#39188043K
Aug 7, 2026
DEFAULT
$6,250
Apr 20, 2026Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A AND 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #908218. AGG1: PRIOR NOV 37026435P UNDER
#37036616N
Jul 31, 2026
DEFAULT
$10,000
Apr 20, 2026Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A AND 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #908219. AGG1: PRIOR NOV 37026421Y UNDER
#37036614J
Jul 31, 2026
DEFAULT
$10,000
Apr 2, 2026Boilers CLASS - 2
AT TIME OF COMPLAINT INSPECTION I FOUND THE WATER BOOSTER PUMP MAKING A LOUD NOISE IN BUILDING 3555 KINGS COLLEGE PL CELLAR, MAINTAIN BOILER; CORRECT ALL VIOLATING CONDITION/ SUBMIT A CERTIFICATE OF CORRECTION
#39182950R
Jul 17, 2026
DEFAULT
$6,250
Apr 2, 2026Boilers CLASS - 2
FOUND A BEST 5E250 BOILER HEATING BOTH BUILDING 3535&3555 LEAKING WATER FROM INSIDE THE BOILER CHAMBER/AIR PROOFING SWICTH NOT WORKING PROPERLY/OIL PUMP MISSING BELT GUARD/ CORRECT ALL VIOLATING CONDITION/SUBMI
#39182942R
Jul 17, 2026
DEFAULT
$6,250
Nov 6, 2025Elevators CLASS - 1
UPON INSPECTION THE DEVICE WAS FOUND OUT OF SERVICE, DEVICE IS UNDER CEASE USE ORDER. REMEDY; REPAIR CEASE USE ORDER THEN CONTACT, NYCDOB FOR A RE-INSPECTION,
#39166172J
Nov 10, 2026
DEFAULT
$3,155
Nov 6, 2025Elevators CLASS - 1
UPON REINSPECTION, THE DEVICE IS FOUND TO BE OUT OF ORDER, BY THE COMMISSIONER ORDER, REMEDY REPAIR CEASE USE ITEMS, THEN CONTACT NYCDOB FOR A RE-INSPECTION .
#39166173L
Nov 10, 2026
DEFAULT
$3,155
Jul 17, 2025Elevators CLASS - 1
CEASE USE ISSUED FOR, DLM A SAFETY DEVICE NOT WORKING. REMEDY; REPAIR THEN AND CONTACT NYCDOB, FOR RESTORE TO SERVICE, RE-INSPECTION,
#39154228L
May 15, 2026
DEFAULT
$6,250
Jun 11, 2025Elevators CLASS - 1
RESPONDING TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION, CEASE USE VIOLATION ISSUED FOR, NO DLM, IN THE CONTROLLER, CAR DOOR RESTRICTOR NOT NOT WORKING, NO ACCESS IN MOTOR ROOM. REMEDY; REPAIR THEN CONTACT NYCD
#39150776Y
Aug 15, 2025
DEFAULT
$3,125
Jan 16, 2024Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A AND 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #908219. REMEDY: FILE ACCEPTABLE REPORT.
#37026421Y
May 3, 2024
DEFAULT
$6,250
Jan 16, 2024Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A AND 9A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITAIL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #908218. REMEDY: FILE ACCEPTABLE REPORT.
#37026435P
May 3, 2024
DEFAULT
$6,250
Dec 2, 2022Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8A AND 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITIONS OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#908218.AGG1:PRIOR NOV 37021178K
#37023944J
Mar 3, 2023
DEFAULT
$10,000
Dec 2, 2022Local Law CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE8A,9A REPORT OF CRITICAL EXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL908219.AGG1:PRIOR NOV 37021180J UNDER 28-302.4.SUBMI
#37024217H
Mar 3, 2023
DEFAULT
$10,000
Oct 26, 2022Construction CLASS - 1
UNLAWFUL ACT:FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER'S OWNERS FAILURE TO COMPLY WITH PREVIOUS ECB VIOLATION#35664286Y ISSUED ON 09/13/2022 TO PROVIDE SAFETY MEASURES FROM UNSAFE FILING.ALSO OF TODAY
#35669276N
Jan 20, 2023
IN VIOLATION
$2,500
Oct 26, 2022Construction CLASS - 1
UNLAWFUL ACT:FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONERS:OWNERS DID NOT COMPLY WITH PREVIOUS ECB VIOLATION#35664287X ISSUED ON 09/13/2022 TO SAFETY MEASURES FROM UNSAFE FILING.AS OF TODAY 10/26/22 NO S
#35669275L
Jan 20, 2023
DEFAULT
$6,250
Sep 13, 2022Construction CLASS - 1
FAILURE TO PROVIDE SAFETY MEASURES TO PROTECT PUBLIC SAFETY FROM DOCUMENTED UNSAFE FACADE.NOTE:QEWI SUBMITTED UNSAFE NOTIFICATION #908219 DATED 8/31/22 HOWEVER AS OF TODAY 9/13/22 SAFETY MEASURES STILL MISSING
#35664287X
Dec 2, 2022
DEFAULT
$25,000
Sep 13, 2022Construction CLASS - 1
FAILURE TO PROVIDE SAFETY MEASURES TO PROTECT PUBLIC SAFETY FROM DOCUMENTED UNSAFE FACADE.NOTE:QEWI SUBMITTED UNSAFE NOTIFICATION #908218 DATED ON 98/31/2022 BUT AS OF TODAY 9/13/22 SAFETY MEASURES STILL MISSIN
#35664286Y
Jan 6, 2023
IN VIOLATION
$10,000
Apr 1, 2021Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#808219.AGG1 PRIOR NOV 37011295K UNDER 2
#37021180J
Oct 1, 2021
DEFAULT
$10,000
Apr 1, 2021Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#808218.AGG1 PRIOR NOV 37011296M UNDER 2
#37021178K
Oct 1, 2021
DEFAULT
$10,000
May 18, 2018Local Law CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#808219. REMEDY: SUBMIT REQUIRED TECHNICAL REPORT
#37011295K
Nov 16, 2018
DEFAULT
$6,250
May 18, 2018Local Law CLASS - 2
FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#808218. REMEDY: SUBMIT REQUIRED TECHNICAL REPORT
#37011296M
Dec 14, 2018
IN VIOLATION
$1,250
DOB (30)
IssuedViolationStatus
Jul 30, 2026CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED THE FOLLOWING CONDITIONS AT EXPOSURE 1 AND 4 CRACKS, DEFLATED LINTELS AND DAMAGED JOINTS. REMEDY: REPAIR AND/OR REPLACE
#SR0705NS
DOB VIOLATION - ACTIVE
Jul 27, 2026CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN A COMPLIANT MANNER. NOTED AT THE TIME OF INSPECTION, OBSERVED CRACK ON THE MORTAR JOINT AT MULTIPLE LOCATION ON EXPOSURE 1, EXPOSURE 3 AND EXPOSURE 4. DAMAGED WINDOW LINTEL AND WINDOW SILL OBSERVED AT EXPOSURE AT EXPOSURE 1 AND EXPOSURE 3. REMEDY: REPAIR AND/OR REPLAC
#SR20704JR
DOB VIOLATION - ACTIVE
Nov 1, 2023FAILURE TO CORRECT SWARMP CONDITIONS (FACADE)
FAILURE TO CORRECT SWARMP CONDITIONS
#00216
DOB VIOLATION - ACTIVE
Nov 1, 2023FAILURE TO CORRECT SWARMP CONDITIONS (FACADE)
FAILURE TO CORRECT SWARMP CONDITIONS
#00215
DOB VIOLATION - ACTIVE
Aug 11, 2023HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#911221
DOB VIOLATION - ACTIVE
Aug 11, 2023HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#911222
DOB VIOLATION - ACTIVE
Apr 22, 2023FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022)
#00111
DOB VIOLATION - ACTIVE
Dec 21, 2022CONSTRUCTION
EMER WRK ORDER TO PROV SFTY MEASURES.SDWALK SHED TO SECURE PUB SAFETY FOR UNSFE FILING 908218A-001 DATED 8/21/2022.AT EXP1 EAST ELEVTION EXP2 SOUTH ELEVATION.PROVIDE SAFETY MEASURES AND REPAIR DAMAHE FACADE AS PER IRCNY-103-04
#FA20702MK
DOB VIOLATION - ACTIVE
Dec 21, 2022CONSTRUCTION
EMER WORK ORDR TO PROV SAFTY MSURES.SDEWALK SHED TO SCURE PUBSFTY @ EXP1 EAST ELEVTION&EXPO34 NRTH ELEVTION TO PRTCT PUB SFTY UNSFE FILING #908219-9A-001 DATED 8/31/2020
#FA20701MK
DOB VIOLATION - ACTIVE
Nov 21, 2022FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2021)
#00020
DOB VIOLATION - ACTIVE
May 31, 2022FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#21X0025
DOB VIOLATION - ACTIVE
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#00921
DOB VIOLATION - ACTIVE
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#00922
DOB VIOLATION - ACTIVE
Jun 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00759
DOB VIOLATION - ACTIVE
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2002520
DOB VIOLATION - ACTIVE
Nov 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00373
DOB VIOLATION - ACTIVE
Aug 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00686
DOB VIOLATION - ACTIVE
Jun 29, 2020FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2019)
#00415
DOB VIOLATION - ACTIVE
May 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00686
DOB VIOLATION - ACTIVE
Nov 8, 2019LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
#03784
DOB VIOLATION - ACTIVE
Mar 18, 2019FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2018)
#00139
DOB VIOLATION - ACTIVE
Feb 17, 2019FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00106
DOB VIOLATION - ACTIVE
May 31, 2018NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
#00506
DOB VIOLATION - ACTIVE
May 31, 2018NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
#00505
DOB VIOLATION - ACTIVE
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#05151
DOB VIOLATION - ACTIVE
Mar 27, 2018FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2017)
#00392
DOB VIOLATION - ACTIVE
Feb 16, 2017FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2016)
#10316
DOB VIOLATION - ACTIVE
Sep 1, 2016FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2015)
#00022
DOB VIOLATION - ACTIVE
Sep 1, 2016FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2014
#30013
DOB VIOLATION - ACTIVE
May 1, 2014FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00253
DOB VIOLATION - ACTIVE
DOB NOW Safety (46)
IssuedViolationStatus
Sep 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Jul 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 1, 2023Facades FISPFCS
CYCLE 9A FAILURE TO CORRECT SWARMP CONDITIONS
Active
Nov 1, 2023Facades FISPFCS
CYCLE 9A FAILURE TO CORRECT SWARMP CONDITIONS
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
Aug 11, 2023Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
Aug 11, 2023Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Report
Active
Apr 22, 2023Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Nov 21, 2022Retro-Commissioning - LL87 FTF-EN-EARCX
Active
May 31, 2022Energy Grade - LL33 FTP-EN-EGRDEA
Active
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
Jun 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Nov 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Jun 29, 2020Retro-Commissioning - LL87 FTF-EN-EARCX
Active
May 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Nov 8, 2019Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Active
Mar 18, 2019Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Feb 17, 2019Benchmarking - LL84 FTF-EN-BENCH
Active
May 31, 2018Facades FISPNRF
FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
Active
May 31, 2018Facades FISPNRF
FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
Active
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
Mar 27, 2018Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Feb 16, 2017Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Sep 1, 2016Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Sep 1, 2016Retro-Commissioning - LL87 FTF-EN-EARCX
Active
May 1, 2014Benchmarking - LL84 FTF-EN-BENCH
Active
HPD (15) · C 1 · B 4 · A 10
IssuedClassViolationCorrect by
Oct 23, 2025BApt 1F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 2nd APARTMENT FROM NORTH AT EASTNov 27, 2025
Oct 23, 2025BApt 1F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK THE CEILING IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 2nd APARTMENT FROM NORTH AT EASTNov 27, 2025
Oct 23, 2025AApt 1F · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 1F, 1st STORY, 2nd APARTMENT FROM NORTH AT EASTJan 26, 2026
Oct 23, 2025AApt 1F · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 2nd APARTMENT FROM NORTH AT EASTJan 26, 2026
Oct 23, 2025BApt 1F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 1F, 1st STORY, 2nd APARTMENT FROM NORTH AT EASTNov 27, 2025
Jun 16, 2025BApt 5D · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK PENETRATING AT EAST WALL IN THE KITCHEN LOCATED AT APT 5D, 5th STORY, 4th APARTMENT FROM NORTH AT EASTJul 21, 2025
Jun 16, 2025AApt 5D · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL IN THE KITCHEN LOCATED AT APT 5D, 5th STORY, 4th APARTMENT FROM NORTH AT EASTSep 19, 2025
Mar 26, 2024A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYJun 29, 2024
Mar 26, 2024A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYJun 29, 2024
Mar 26, 2024A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.Jun 29, 2024
Mar 26, 2024A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYJun 29, 2024
Mar 26, 2024A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORYJun 29, 2024
Mar 26, 2024C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORYApr 1, 2024
Mar 26, 2024A§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORYJun 29, 2024
Mar 26, 2024A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORYJun 29, 2024

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026ECBElevators: CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE, AS PER ASME A17.1-2013 8.6.4.13.1, AS MODIFIED BY NYC APPENDIX K. REPAIR AND EMAIL EIR@BUILDINGS.NYC.GOV FOR RE-INSPECTION. CLASS 2 ITEMS: DEBRIS PRESENT ON CAROpen
Sep 30, 2026DOB SafetyAEUHAZ: Open
Jul 30, 2026DOBCONSTRUCTION: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED THE FOLLOWING CONDITIONS AT EXPOSURE 1 AND 4 CRACKS, DEFLATED LINTELS AND DAMAGED JOINTS. REMEDY: REPAIR AND/OR REPLACEOpen
Jul 30, 2026DOB SafetyAEUHAZ: Open
Jul 27, 2026DOBCONSTRUCTION: FAILURE TO MAINTAIN BUILDING IN A COMPLIANT MANNER. NOTED AT THE TIME OF INSPECTION, OBSERVED CRACK ON THE MORTAR JOINT AT MULTIPLE LOCATION ON EXPOSURE 1, EXPOSURE 3 AND EXPOSURE 4. DAMAGED WINDOW LINTEL AND WINDOW SILL OBSERVED AT EXPOSURE AT EXPOSURE 1 AND EXPOSURE 3. REMEDY: REPAIR AND/OR REPLACOpen
Jul 27, 2026ECBConstruction: PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. NOTED AT THE TIME OF INSPECTION I OBSERVED DEFECTIVE/INADEQUATE AND DAMAGED/ROTTED MUDSILLS AT MULTIPLE LOCATIONS WHICH ARE NOT IN COMPLIANCE WITH NYC ADOpen