2 floors · 9,608 sq ft · built 1962 · class K2 · owner of record: Alzandoni, Wahdah
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 42 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 773 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 23, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.ILLUMINATION FOR EXITS DISCHARGES AND PUBLIC CORRIDORS PER BC1006.1;27-381.NOTED:NONE OF THE EMERGENCY LIGHTING AT THE 2ND FLR WAS OPERATIONAL AT THE TIME #35407535Z | Dec 11, 2019 IN VIOLATION | $312 |
| Aug 23, 2019 | Construction CLASS - 1 FAILURE TO PROVIDE AN OBSTRUCTED EXIT PASSAGEWAY.NOTED:AT SECOND FLR EMERGENCY EXIT STAIRWELL BOXES AND BAGS WERE STORED CREATING AN OBSTRUCTION OF EGRESS. EGRESS PATH(STAIRWELL)MUST BE MAINTAINED CLEAN OF ALL #35407533P | Dec 11, 2019 IN VIOLATION | $1,250 |
| Aug 23, 2019 | Construction CLASS - 2 APPROVED PLACE OF ASSEMBLY PLANS NOT AVAILABLE FOR INSPECTION.NOTED:P.A. PLAN AVAILABLE WAS OUTDATED.NEW PLANS COULD NOT BE PROVIDED AT THE TIME OF INSPECTION.REM:PROVIDE APPROVAL PLACE OF ASSEMBLY PLANS. #35407536K | Dec 11, 2019 IN VIOLATION | $500 |
| Aug 23, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTED:AT 2NF LR BOTH EGRESS DOORS WERE EQUIPPED WITH SLIDE BOLTS.SECONDARY EXIT HAD BOLT FIXED IN TIE,LOCKED POSITION WHILE PLACE OF ASSEMBLY WAS OCCUPIED #35407534R | Dec 11, 2019 IN VIOLATION | $1,250 |
| Mar 11, 2010 | Construction CLASS - 2 WORK W.O PERMIT. NOTED: INSTALLED NEW HOT WATER TANK AT LOCATION OF GUILLE'S HAIR SALON 718-727-7921 AT REAR OF LOCATION. APPROX 12 COPPER PIPE INSTALLED. REMEDY: OBTAIN PERMIT. #34835926K | Jun 9, 2010 WRITTEN OFF | $0 |
| May 27, 2008 | Construction Hazardous OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O 085805 1ST FL AS 2 RETAIL STORES BILLARD PARLOR AND ACC GARAGE AT TIME OF INSPECTION NO BILLIARD PARLOR AT 1ST 5 RETAIL SPACES CONTRARY TO C/O REMEDY: DISCONTINU #34648210L | Jul 16, 2008 IN VIOLATION | $0 |
| Oct 18, 2007 | Construction Non-Hazardous WORK DOES NOT CONFORM TO APPROVED PLANS.PLAN/ALT#451/86 4 STORES OCCUPYING 1ST FL.2 CLASS A APTS RECORD FL REAR EXTENSION ASSED WEST SIDE REAR STEEL PLATES ENCLOSING SECURITY RM 1/4 INCH ON PLAN 3/8 STEEL INSTA #34585269K | Apr 9, 2008 IN VIOLATION | $0 |
| Oct 17, 2007 | Quality of Life Non-Hazardous WORK W/O PERMIT. NOTED: REAR OF BLDG EXTENDED APPROX 10' X 30' (2) STORYS HIGH. ALL BLOCK CONSTRUCTION NO PERMITS OR APPROVALS. REMEDY: OBTAIN PERMIT OR RESTORE LEGAL PRIOR CONDITION. #34608681L | Apr 9, 2008 IN VIOLATION | $0 |
| Oct 17, 2007 | Quality of Life Non-Hazardous W/O PERMIT WORK NOTED: AT 1ST AND 2 & FL WATER & WASTE LINES INSTALLED FOR 5 BATHROOM(2) ON 1ST FL REAR OF BLDG (3) ON 2ND FL ALSO GAS LINESINSTALLED FOR (2) GAS STOVES ON 1 ST FL. AND 1 ON 2ND FL #34608680J | Apr 9, 2008 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 28, 2001 | CONSTRUCTION #0101AP | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Feb 28, 2001 | CONSTRUCTION #0102AP | DOB VIOLATION - ACTIVE |
| Apr 6, 1999 | CONSTRUCTION #0201L | DOB VIOLATION - ACTIVE |
| Apr 6, 1999 | CONSTRUCTION #0202L | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Apr 6, 1999 | ZONING #0203L | DOB VIOLATION - ACTIVE |
| Aug 27, 1997 | CONSTRUCTION #0101L | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 19, 2026, 2:15 PM ET. BBL 5010910032.