21 floors · 73 apartments · 60,576 sq ft · built 2015 · class RM · owner of record: Unavailable Owner
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 61 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 77 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 60,576 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 182 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 182 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 305 days | Registered through 2027-09-01 |
| Energy audit and retro-commissioning (2027) Likely applies Local Law 87 · Calendar year 2027 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 167). Agency page | Dec 31, 2027 in 426 days | Next due 2027 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1157 days | Next cycle year 2029 |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page | On file | Cycle 10 filing on record: SAFE (2026-02-24) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 23, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION IN RESPONSE TO AN INCIDENT WHERE A PIECE OF SCAFFOLD FRAME CAME OFF THE BUILDING DURING INSTALLATION AND DAMAGED 2 PARKED CARS ON THE STREET, INSPECTION REVEAL A ROTTEN FRAME CONNECTING RO #39546291R | Jun 1, 2027 DEFAULT | $10,030 |
| Oct 23, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION IN RESPONSE TO AN INCIDENT WHERE A PIECE OF SCAFFOLD FRAME CAME OFF THE BUILDING DURING INSTALLATION AND DAMAGED 2 PARKED CARS ON THE STREET, INSPECTION REVEAL A ROTTEN FRAME CONNECTING RO #39546289H | Jul 17, 2026 DEFAULT | $12,500 |
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Dec 3, 2024 | B | Apt 10D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 10D, 10th STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17146562 ISSUED 27-JUL-24 HAS BEEN UPGRADED TO CLASS B PER ADMINI | Jan 7, 2025 |
| Dec 3, 2024 | B | Apt 10D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CELING AND EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 10D, 10th STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17146565 ISSUED 27-JUL-24 HAS BEEN UPGRADED TO CLASS B | Jan 7, 2025 |
| Aug 1, 2024 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT FRONT ENTRANCE DOOR TO BUILDING , 1st STORY | Aug 7, 2024 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 31, 2026, 1:05 PM ET. BBL 3001677501.