6 floors · 57 apartments · 66,000 sq ft · built 1931 · class D7 · owner of record: 916 Holding Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 46 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 62 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 66,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 167 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 167 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 290 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1142 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2851). Agency page | Dec 31, 2031 in 1872 days | Next due 2031 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-02 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 8, 2026 | Elevators CLASS - 2 CLASS 2 ITEMS: IN-CAR EMERGENCY COMMUNICATION DEVICE IS NOT CONNECTED TO A CONTINUOUSLY STAFFED LOCATION AS REQUIRED BY APPENDIX K. PROVIDE A FUNCTIONAL TWO-WAY EMERGENCY COMMUNICATION SYSTEM CONNECTED TO A CON #39203244J | Nov 20, 2026 PENDING | $625 |
| Apr 8, 2025 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #912161. REMEDY: SUBMIT ACCEPTABLE REQU #37034842M | Oct 24, 2025 IN VIOLATION | $0 |
| Jan 16, 2010 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALLS NOTED LOOSE BRICKS AND OPEN CRACK OBSERVED AT EXPOSURE #AND#4 REMEDY MAINTAIN EXTERIOR BUILDING WALL. #34821240Z | May 21, 2010 WRITTEN OFF | $0 |
| Aug 31, 2000 | Local Law Non-Hazardous FAILURE TO FILE A REPORT OF COMPLIANCE WITH LOCAL LAW 16/84 CERTIFYING TO THE INSTALLTION OF REQUIRED FIRE PROTECTION SYSTEMS.REMEDY:FILE REPORT. #34261220Z | May 18, 2001 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #03729 | DOB VIOLATION - ACTIVE |
| Sep 15, 2017 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST #01974 | DOB VIOLATION - ACTIVE |
| Jan 3, 2017 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST #04703 | DOB VIOLATION - ACTIVE |
| Nov 14, 2016 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST #05269 | DOB VIOLATION - ACTIVE |
| Mar 21, 2003 | LOCAL LAW 10/81 - ELEVATOR #01557 | DOB VIOLATION - ACTIVE |
| Feb 19, 2002 | LOCAL LAW 10/81 - ELEVATOR #01973 | DOB VIOLATION - ACTIVE |
| Mar 26, 1993 | CONSTRUCTION #NEMS01 | VIOLATION UNSERVED ECB-ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 6, 2019 | Elevators ACC1 | Active |
| Sep 15, 2017 | Elevators EVCAT1 | Active |
| Jan 3, 2017 | Elevators ACC1 | Active |
| Nov 14, 2016 | Elevators ACC1 | Active |
| Mar 21, 2003 | Elevators LL1081 | Active |
| Feb 19, 2002 | Elevators LL1081 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 10, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POTS AT 5TH STORY BALCONY FRIST FIRE ESCAPE FROM WEST AT SOUTH AT FIRE ESCAPE, 5th STORY | Dec 15, 2026 |
| Nov 4, 2026 | B | Apt 6G · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , S | Dec 9, 2026 |
| Nov 2, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | Nov 8, 2026 |
| Oct 28, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POTS AT 5TH STORY BALCONY AT FRIST FIRE ESCAPE FROM WEST AT SOUTH AT FIRE ESCAPE, 5th STORY | Dec 2, 2026 |
| Oct 26, 2026 | C | Apt 1E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''EAST'' | Nov 21, 2026 |
| Oct 26, 2026 | C | Apt 1E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''EAST'' | Nov 21, 2026 |
| Oct 21, 2026 | B | Apt 5G · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5G, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 25, 2026 |
| Oct 21, 2026 | B | Apt 5G · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5G, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Nov 25, 2026 |
| Oct 20, 2026 | A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Jan 23, 2027 |
| Sep 11, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND SOUTH WALL AT PUBLIC HALL, 1st STORY | Oct 16, 2026 |
| Sep 11, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND SOUTH WALL AT PUBLIC HALL, 1st STORY | Dec 15, 2026 |
| Sep 3, 2026 | B | Apt 4C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SUBFLOOR (SLOPING AND SAGGING) IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4C, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST | Oct 8, 2026 |
| Sep 3, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF PLANT POTS AT 5TH STORY BALCONY AT 1ST FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL AT FIRE ESCAPE | Oct 8, 2026 |
| Sep 3, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 1st STORY | Oct 8, 2026 |
| Sep 3, 2026 | B | Apt 4C · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF VINYL FLOOR TILES ( LIFTING AND MISSING) IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4C, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST | Oct 8, 2026 |
| Sep 3, 2026 | B | Apt 4C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM FROM THE BUILDING ENTRANCE DOOR TO PANEL AT EAST WALL IN THE FOYER LOCATED AT APT 4C, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST | Oct 8, 2026 |
| Sep 3, 2026 | C | Apt 4C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST | Sep 29, 2026 |
| Jul 6, 2026 | C | Apt 3H · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT ALL ELECTRICAL OUTLET, FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jul 12, 2026 |
| Apr 27, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSE HOLD ITEMS AT 5TH STORY BALCONY AT 1ST FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL AT FIRE ESCAPE, 5th STORY | Jun 1, 2026 |
| Apr 27, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES TO TRASH ROOM DOOR AT PUBLIC HALL, 6th STORY | May 11, 2026 |
| Apr 27, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES TO TRASH ROOM DOOR AT PUBLIC HALL, 5th STORY | May 11, 2026 |
| Apr 22, 2026 | B | Apt 5C · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , S | May 27, 2026 |
| Apr 22, 2026 | B | Apt 5C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQ. FT. AT 1ST AND 2ND WINDOW FRAMES FROM WEST AT NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' | May 27, 2026 |
| Apr 22, 2026 | C | Apt 5C · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' | Apr 22, 2026 |
| Apr 22, 2026 | C | Apt 6B · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' | Apr 22, 2026 |
| Apr 22, 2026 | B | Apt 6B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE KNOB AT SHUT OFF VALVE AT NORTH WALL RADIATOR IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' | May 27, 2026 |
| Apr 22, 2026 | B | Apt 6B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE KNOB AT SHUT OFF VALVE AT SOUTH WALL RADIATOR IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' | May 27, 2026 |
| Apr 22, 2026 | B | Apt 6B · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SEC | May 27, 2026 |
| Apr 22, 2026 | B | Apt 6B · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE. IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , | May 27, 2026 |
| Apr 22, 2026 | C | Apt 5C · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' | Apr 22, 2026 |
| Apr 22, 2026 | B | Apt 5C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CRACKED, CHIPPED, MISSING FLOOR TILES BENEATH NORTH WALL RADIATOR IN THE 1st ROOM FROM NORTH LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' | May 27, 2026 |
| Apr 22, 2026 | B | Apt 5C · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE ESCUTCHEON PLATE AT RISER, AT CEILING IN THE BATHROOM LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' | May 27, 2026 |
| Apr 22, 2026 | B | Apt 5C · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SEC | May 27, 2026 |
| Apr 22, 2026 | B | Apt 5C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HANDLE TO RADIATOR SHUT OFF VALVE IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5C, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' | May 27, 2026 |
| Apr 13, 2026 | A | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER TACK WELDED, SECURE USING APPROPRIATE NUTS AND BOLTS AT 1ST FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL, BUILDING'S FRONT AT FIRE ESCAPE | Jul 17, 2026 |
| Apr 13, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES TO DOOR AT TRASH ROOM AT PUBLIC HALL, 6th STORY | Apr 27, 2026 |
| Mar 30, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES TO TRASH ROOM DOOR AT PUBLIC HALL, 6th STORY | Apr 13, 2026 |
| Feb 2, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | Feb 8, 2026 |
| Feb 2, 2026 | C | Apt 1B · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM EAST LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 2, 2026 |
| Jan 26, 2026 | C | Apt 3G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 21, 2026 |
| Jan 26, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM | Feb 1, 2026 |
| Jan 26, 2026 | C | Apt 6F · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 25, 2026 |
| Jan 26, 2026 | C | Apt 3G · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 25, 2026 |
| Jan 26, 2026 | C | Apt 3G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 21, 2026 |
| Jan 20, 2026 | A | Apt 2F · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT ALL WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Apr 25, 2026 |
| Jan 20, 2026 | C | Apt 2F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Jan 26, 2026 |
| Jan 20, 2026 | C | Apt 2F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 26, 2026 |
| Jan 20, 2026 | B | Apt 2F · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Feb 24, 2026 |
| Jan 20, 2026 | B | Apt 2F · § 27-2005 ADM CODE PROVIDE DOOR AT LOWER CABINET AT SINK IN THE KITCHEN LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Feb 24, 2026 |
| Jan 20, 2026 | B | Apt 2F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR AT SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Feb 24, 2026 |
| Jan 20, 2026 | B | Apt 2F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENAMEL FINISH BY METHOD OF REGLAZING AT BATHTUB IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Feb 24, 2026 |
| Jan 20, 2026 | B | Apt 2F · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER HINGE AT CLOSET DOOR IN THE PRIVATE HALLWAY LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Feb 24, 2026 |
| Jan 20, 2026 | B | Apt 2F · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Feb 24, 2026 |
| Jan 20, 2026 | B | Apt 2F · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Feb 24, 2026 |
| Jan 20, 2026 | C | Apt 2F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Feb 15, 2026 |
| Jan 20, 2026 | C | Apt 2F · 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | Feb 15, 2026 |
| Dec 22, 2025 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | Dec 28, 2025 |
| Dec 18, 2025 | C | Apt 6K · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6K, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''WEST'' | Dec 17, 2025 |
| Nov 24, 2025 | A | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER TACK WELDED, PROPERLY SECURE BY USING NUTS AND BOLT TO SECURE 1ST FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL, WEST SECTION. AT FIRE ESCAPE | Feb 27, 2026 |
| Nov 24, 2025 | B | Apt 6F · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE DOOR KNOB, AT DOOR IN THE ENTRANCE LOCATED AT APT 6F, 6th STORY, 2nd APARTMENT FROM WEST AT NORTH | Dec 29, 2025 |
Showing 60 of 147. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Nov 10, 2026 | HPD B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POTS AT 5TH STORY BALCONY FRIST FIRE ESCAPE FROM WEST AT SOUTH AT FIRE ESCAPE, 5th STORY | Open |
| Nov 4, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 1st APARTMENT FROM WEST AT NORTH , S | Open |
| Nov 2, 2026 | HPD C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | Open |
| Oct 28, 2026 | HPD B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POTS AT 5TH STORY BALCONY AT FRIST FIRE ESCAPE FROM WEST AT SOUTH AT FIRE ESCAPE, 5th STORY | Open |
| Oct 26, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''EAST'' | Open |
| Oct 26, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1E, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''EAST'' | Open |
| Oct 21, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5G, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Oct 21, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5G, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Open |
| Oct 20, 2026 | HPD A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Open |
| Oct 20, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5G, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Closed |
| Sep 11, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND SOUTH WALL AT PUBLIC HALL, 1st STORY | Open |
| Sep 11, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND SOUTH WALL AT PUBLIC HALL, 1st STORY | Open |
| Sep 8, 2026 | ECB | Elevators: CLASS 2 ITEMS: IN-CAR EMERGENCY COMMUNICATION DEVICE IS NOT CONNECTED TO A CONTINUOUSLY STAFFED LOCATION AS REQUIRED BY APPENDIX K. PROVIDE A FUNCTIONAL TWO-WAY EMERGENCY COMMUNICATION SYSTEM CONNECTED TO A CON | Open |
| Sep 3, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SUBFLOOR (SLOPING AND SAGGING) IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4C, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST | Open |
| Sep 3, 2026 | HPD B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF PLANT POTS AT 5TH STORY BALCONY AT 1ST FIRE ESCAPE FROM WEST AT SOUTH EXTERIOR WALL AT FIRE ESCAPE | Open |
| Sep 3, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 1st STORY | Open |
| Sep 3, 2026 | HPD B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF VINYL FLOOR TILES ( LIFTING AND MISSING) IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 4C, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST | Open |
| Sep 3, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL BUZZER INTERCOM SYSTEM FROM THE BUILDING ENTRANCE DOOR TO PANEL AT EAST WALL IN THE FOYER LOCATED AT APT 4C, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST | Open |
| Sep 3, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 3rd APARTMENT FROM WEST AT NORTH , SECTION AT EAST | Open |
| Aug 14, 2026 | ECB | Elevators: CLASS 2 ITEMS: IN-CAR EMERGENCY COMMUNICATION DEVICE IS NOT CONNECTED TO A CONTINUOUSLY STAFFED LOCATION AS REQUIRED BY APPENDIX K. PROVIDE A FUNCTIONAL TWO-WAY EMERGENCY COMMUNICATION SYSTEM CONNECTED TO A CON | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 15, 2026, 1:04 PM ET. BBL 2028510036.