| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 290 days | Required only if the owner doesn't live there |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 11, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, ACTIVE 8-STORY BUILDING IN FINISH PHASE. SIDEWALK SHED AT EXPOSURE 1 NOT MAINTAINED. BURIED SHED COMPONENTS (MUDSILL) OBSERVED. ACTIVE STORAGE ZONE NOT MAINTAINED, WITH GENERATOR STORED W #39555361H | Aug 21, 2026 IN VIOLATION | $2,400 |
| Jun 11, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, ACTIVE 8-STORY BUILDING IN FINISH PHASE. MEANS OF EGRESS AT EXPOSURE 1 OBSTRUCTED BY PORTABLE TOILET AND DEBRIS, REDUCING THE REQUIRED CLEAR EXIT PATH. OBSTRUCTED EGRESS MAY DELAY OCCUPAN #39555362J | Aug 21, 2026 IN VIOLATION | $625 |
| May 14, 2026 | Construction CLASS - 1 AT THE TIME OF INSPECTION OF A 8- STORY NEW BUILDING, I OBSERVED INADEQUATE HOUSEKEEPING THROUGHOUT JOBSITE AND ENTRANCE INSIDE BUILDING LARGE AMOUNT OF DEBRIS, CARDBOARD BOX, WOOD AND GARBAGE BAG FILL WITH DEB #39554140J | Mar 12, 2027 | $2,500 |
| May 14, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION OF A 8-STORY NEW BUILDING, ACTIVE SITE I OBSERVED WORKER ON 8-FLOOR INTERIOR STAIRWAY USING A-FRAME LADDER NOT AS PER MANUFACTURER SPECIFICATIONS A-FRAME LADDER WAS CLOSED AND LEANING #39554141L | Mar 12, 2027 | $1,250 |
| May 14, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION OF A 8-STORY NB, ACTIVE JOBSITE STUCCO WORK IN PROGRESS USING SUPPORTED PIPE SCAFFOLDING, I ALSO OBSERVED STUCCO RESIDUE AND DEBRIS IN ADJACENT PROPERTIES AND FLYING IN AIR. FAILURE TO #39554143P | Mar 12, 2027 PENDING | $5,000 |
| May 14, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION, WORKERS WERE OBSERVED USING ELECTRIC HAND GRINDERS TO CUT PIPE AND CERAMIC TILE CONTRARY TO MANUFACTURER SPECIFICATIONS. GRINDERS WERE MISSING REQUIRED SIDE HANDLES, RESULTING IN UNST #39554142N | Mar 12, 2027 | $1,250 |
| Apr 23, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, ACTIVE 8-STORY NEW BUILDING. PUMP JACK INSTALLED AT EXPOSURE 2 NOT SHOWN ON APPROVED PLANS. CONDITION MAY RESULT IN IMPROPER INSTALLATION AND UNSAFE OPERATION, CREATING RISK OF COLLAPSE A #39553411H | Dec 4, 2026 IN VIOLATION | $625 |
| Apr 23, 2026 | Unknown CLASS - 1 AT TIME OF INSPECTION, 8-STORY NEW BUILDING. SITE SAFETY MANAGER PAUL JOHNSON NOT PRESENT; ALTERNATE GENESIS RIERA PROVIDING COVERAGE WITHOUT DOB NOTIFICATION. FAILURE TO PROPERLY DESIGNATE AND NOTIFY CREATES I #39553420J | Jan 15, 2027 | $5,000 |
| Apr 23, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, ACTIVE 8-STORY NEW BUILDING. PUMP JACK INSTALLED AT ROOF LEVEL AT EXPOSURE 2 FROM ADJACENT ROOF TO BUILDING ROOF WITHOUT LOAD IMPOSED LETTER. CONDITION IS NOT VERIFIED FOR SAFE USE AND MA #39553412J | Dec 4, 2026 IN VIOLATION | $1,250 |
None open.
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 15, 2026, 8:43 PM ET. BBL 2028390032.