5 floors · 15 apartments · 22,328 sq ft · built 1900 · class C4 · owner of record: 348-58 W 47th St Associates, L.P.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 58 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 58 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 74 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 302 days | Registered through 2027-09-01 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-20 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 19, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR VIOLATING CONDITIONS CITED ON NOV#35374018M ISSUED ON 05/15/2018 PURSUANT TO SECTION:28-2 #35587149L | May 12, 2022 IN VIOLATION | $1,250 |
| Aug 19, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR VIOLATING CONDITIONS CITED ON NOV#35321426M ISSUED ON 04/10/2018 PURSUANT TO SECTION:28-2 #35587147H | May 12, 2022 IN VIOLATION | $1,250 |
| Aug 19, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR VIOLATING CONDITIONS CITED ON NOV#34923800P ISSUED ON 08/09/2011 PURSUANT TO SECTION:28-2 #35587148J | May 12, 2022 IN VIOLATION | $1,250 |
| Jul 27, 2019 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. OBSERVED BUILDING IN DISREPAIR. WITH TREADS ID STAIRCASE LEADING TO 3RD, 4TH, AND 5TH FLOOR LOOSE PULLING AWAY FROM WALL, LEANING AND SAGGING. REMEDY: RE #35407263Y | Dec 26, 2019 IN VIOLATION | $312 |
| May 15, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLAIMT MANNER. ENTIRE INTERIOR STAIRCASE NOOT PLUMB/LEVELED. STAIRS LEADING FROM 2ND FLOOR TO 3RD FLOOR ARE NOT STRUCTURALLY STABLE. STAIR WAS ALOT OF MOVEMENT. TEMPORARY #35374018M | Jul 11, 2019 IN VIOLATION | $625 |
| May 5, 2018 | Plumbing CLASS - 1 FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER.LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQD PER BC 903.2;27-954 FOR TRANSIENT USE.REM:DISCONTINUE ILLEGAL OCCUPANCY. #35329675J | May 9, 2019 IN VIOLATION | $1,000 |
| May 5, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.FAILURE TO PROVIDE #OF REQD MEANS OF EGRESS FOR EVERY FLOOR PER BC 102.1 AND BC 1018.1;27-366 FOR TRANSIENT USE.REM:DISCONTINUE ILLEGAL OCCUPANCY #35329676L | May 9, 2019 IN VIOLATION | $2,500 |
| May 5, 2018 | Construction CLASS - 1 BC907.2.8:FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE.REM:DISCONTINUE ILLEGAL OCCUPANCY. #35329677N | May 9, 2019 IN VIOLATION | $2,500 |
| May 5, 2018 | Quality of Life CLASS - 2 PERMANENT DWELLING USED/CONNECTED FOR OTHER THAN PERMANENT RESIDENTIAL PURPOSES C/O#29133 INDICATS BLDG TO BE LEGALLY APPROVED AS A CLASS"A'MID.NOW,APT 2E ILLEGALLY USED/CONVERTED TO TRANSIENT USE.REM:DISCONTIN #35329649X | May 9, 2019 IN VIOLATION | $1,250 |
| Apr 11, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES. NOTED: DETERIORATION OF FACADE (FRONTAGE APPRX 30') AS WELL AS CRACKING. MAJOR LOCATIONS OF DETERIORATION AND CRACKING ARE AROUND WINDOWS ON THE 2ND FLR 3RD FL #35321291Y | May 9, 2019 IN VIOLATION | $2,500 |
| Apr 10, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER: LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1 (2008 CODE) 27-366; BC 1021.1 (2014 CODE) FOR TRANSIENT USE. PREVIOUS VIOLATION #S #35321324L | May 23, 2019 IN VIOLATION | $2,500 |
| Apr 10, 2018 | Construction CLASS - 1 BC907.2.8 FAILURE TO PROVIDE CLASS "J" FIRE ALARM SYSTEM FOR TRANSIENTUSE. PREVIOUS VIOLATIONS 35220707X,35169317J,35169854P. RMDY: DISCON TINUE ILLEGAL OCCUPANCY. #35321425K | May 23, 2019 IN VIOLATION | $6,250 |
| Apr 10, 2018 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DOB FOR VIOLATING CONDITIONS CITED IN NOV # 34923800P. RMDY: FILE A CERTIFICATE OF CORRECTION. #35321426M | May 23, 2019 IN VIOLATION | $1,250 |
| Apr 10, 2018 | Plumbing CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.2; 27-954 FOR TRANSIENT USE. PREVIOUS VIOLATION #S 35169315X,35220706Y,35169852L.RMDY #35321323J | May 23, 2019 IN VIOLATION | $2,500 |
| Apr 22, 2011 | Boilers CLASS - 1 B154,3B,15,16,24B,32,38,48A,50,50A,B,C,D,E,F,G,H. SHUT DOWN FUMES. 50A- NO DAR KIT FOR OIL PUMP. 50B- FRESH AIR FAN NOT WORKING. 50C- SOOT ON BOILER. 50D- GASKET FALLING OF ON REAR DOOR. 50E- NO CLEAN OUT. #32070594Z | Aug 11, 2011 IN VIOLATION | $0 |
| Feb 17, 2009 | Construction CLASS - 1 "STOP ALL WORK".PLUMBING WORK W/O A PERMIT.APT 5A A*STOP WORK ORDER* DEMOLITION,ALTERATION,NEW INSTALLATION OF GAS,WASTE,VENT,WATER PIPING IN APT 5A FOR USE OF KITCHEN & TWO BATHROOMS.NO "PL" WORK TYPE PERMIT #34754784J | Aug 26, 2010 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 28, 2024 | CONSTRUCTION ENGINEER REPORT REQUESTED AND BUILDING RENDERED NON COMPLIANT DUE TO F IRE IN CELLAR@ APT. 1A& 1B. CHARRING NOTED ON JOIST IN CELLAR BATHROOM S , WALLS REMOVED CELLAR /GROUND FLOOR APT. 1A/1B, HOLE IN CELLAR EXTE NDS INTO EXTERIOR LIGHTWELL FLOOR. UNSAFE CONDITIONS REQUIRE VACATE OF APT. 1A & APT. 1 #CER02JG | DOB VIOLATION - ACTIVE |
| Jan 6, 2006 | LOCAL LAW 62/91 - BOILERS #01079 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 6, 2006 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Dec 18, 2024 | I | § 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS AT APT.1A , 1ST STORY EAST-1 WITH VACATE NUMBER 259041, POSTED DATE 12/18/2024 IN THE ENTIRE APARTMENT LOCATED AT APT, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | — |
| Dec 18, 2024 | I | § 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS AT APT. 1B 1ST STORY SOUTH-1 WITH VACATE NUMBER 259041, POSTED DATE 12/18/2024 IN THE ENTIRE APARTMENT LOCATED AT APT, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | — |
| Oct 15, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 3rd STORY | Jan 18, 2027 |
| Oct 15, 2026 | B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 3rd STORY | Nov 19, 2026 |
| Oct 15, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1st STORY | Jan 18, 2027 |
| Oct 15, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 3rd STORY | Nov 19, 2026 |
| Oct 15, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 1st STORY | Nov 19, 2026 |
| Oct 5, 2026 | B | Apt 3E · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS ...DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 9, 2026 |
| Oct 5, 2026 | B | Apt 3E · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES ...DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 9, 2026 |
| Oct 5, 2026 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ...AT CEILING AT PUBLIC HALL, 3rd STORY | Jan 8, 2027 |
| Oct 5, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ...FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 3rd STORY | Nov 9, 2026 |
| May 8, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 11, 2026 |
| Apr 16, 2026 | C | 567 (C) § 27-2017, 27-2017.1, 27-2017.4, 27-2017.5, 27-2017.8, 27-2019, 27-2021 HMC: ABATE THE NUISANCE CONSISTING OF EVIDENCE OF RATS AND ALL UNDERLYING CAUSES CREATING THE PEST INFESTATIONS, BY USING INTEGRATED PEST MANAGEMENT (IPM), ELIMINATE ALL BURROW ENTRY AND PASSAGEWAYS, PEST NESTS, HOLES, G | May 12, 2026 |
| Feb 2, 2026 | B | Apt 3A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 9, 2026 |
| Feb 2, 2026 | C | Apt 3A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 28, 2026 |
| Jun 13, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 16, 2025 |
| Feb 7, 2025 | C | Apt 4A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Feb 13, 2025 |
| Jan 31, 2025 | C | Apt 5B · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5B, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 6, 2025 |
| Jan 13, 2025 | C | Apt 2B · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 19, 2025 |
| Jan 13, 2025 | C | Apt 2A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 19, 2025 |
| Jan 13, 2025 | C | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT WALLS AND CEILING AT CELLAR | Jan 19, 2025 |
| Jan 13, 2025 | C | § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE AT THE CELLAR AT CELLAR | Jan 19, 2025 |
| Dec 23, 2024 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BASEMENT AT BOILER ROOM | Dec 29, 2024 |
| Dec 23, 2024 | C | Apt 1B · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 6, 2025 |
| Dec 23, 2024 | B | Apt 1B · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 27, 2025 |
| Dec 23, 2024 | C | Apt UNIT 2 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT UNIT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 6, 2025 |
| Dec 23, 2024 | C | Apt UNIT 2 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT UNIT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 21, 2024 |
| Dec 23, 2024 | B | Apt 1B · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 27, 2025 |
| Dec 13, 2024 | C | Apt 1A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 19, 2024 |
| Dec 13, 2024 | C | Apt 1B · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 19, 2024 |
| Dec 12, 2024 | B | Apt 3B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 16, 2025 |
| Dec 12, 2024 | B | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS FIRE ESCAPE AT BUILDING REAR. | Jan 16, 2025 |
| Dec 12, 2024 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITION UNIT PROTUDING MORE THAN 4 INCHES FROM WINDOWSILL AT 3RD STORY BALCONY FIRE ESCAPE AT BULDNG FRONT | Jan 16, 2025 |
| Dec 12, 2024 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITION UNIT PROTUDING MORE THAN 4 INCHES FROM WINDOWSILL AT 5TH STORY BALCONY FIRE ESCAPE AT BULDNG FRONT | Jan 16, 2025 |
| Dec 12, 2024 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITION UNIT PROTUDING MORE THAN 4 INCHES FROM WINDOWSILL AT 4TH STORY BALCONY FIRE ESCAPE AT BULDNG FRONT | Jan 16, 2025 |
| Dec 12, 2024 | C | Apt 3B · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES IN THE BATHROOM AND KITCHEN IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 18, 2024 |
| Dec 12, 2024 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES AIR CONDITION UNIT PROTUDING MORE THAN 4 INCHES FROM WINDOWSILL AT 2ND STORY BALCONY FIRE ESCAPE AT BULDNG FRONT, | Jan 16, 2025 |
| Dec 2, 2024 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Dec 8, 2024 |
| Dec 2, 2024 | C | Apt 4C · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Dec 1, 2024 |
| Apr 17, 2024 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 21, 2024 |
| Mar 26, 2024 | C | Apt 5A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH LEADING TO FIRE ESCAPE NW1 ROOM IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 1, 2024 |
| Mar 26, 2024 | C | Apt 2A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT THE DOOR LEADING TO FIRE ESCAPE WINDOW IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 1, 2024 |
| Mar 26, 2024 | C | Apt 2A · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES IN THE ENTRANCE LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 9, 2024 |
| Mar 25, 2024 | C | Apt 2A · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 23, 2024 |
| Mar 25, 2024 | C | Apt 2A · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 24, 2024 |
| Mar 25, 2024 | C | Apt 2A · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 24, 2024 |
| Mar 25, 2024 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED AT CELLAR | Mar 31, 2024 |
| Mar 25, 2024 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM AT CELLAR | Mar 31, 2024 |
| Mar 25, 2024 | C | Apt 2A · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 23, 2024 |
| Mar 31, 2023 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 4, 2023 |
| Mar 10, 2022 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jun 13, 2022 |
| Aug 12, 2021 | B | Apt 1C · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Sep 16, 2021 |
| Aug 12, 2021 | C | Apt 1C · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Sep 7, 2021 |
| Aug 12, 2021 | B | Apt 1C · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Sep 16, 2021 |
| Aug 12, 2021 | B | Apt 1C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Sep 16, 2021 |
| Aug 12, 2021 | B | Apt 1C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Sep 16, 2021 |
| Aug 12, 2021 | B | Apt 1C · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN BATHTUB WASTE LINE IN THE BATHROOM LOCATED AT APT 1C, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTH | Sep 16, 2021 |
| Apr 20, 2021 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 24, 2021 |
| Dec 9, 2020 | B | Apt 1C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... at ceiling approx 4 square feet IN THE BATHROOM LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 13733273 ISSUED 10-AUG-20 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-20 | Jan 13, 2021 |
| Oct 16, 2020 | C | Apt 1C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY | Nov 11, 2020 |
Showing 60 of 142. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 15, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 3rd STORY | Open |
| Oct 15, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AT PUBLIC HALL, 3rd STORY | Open |
| Oct 15, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AT PUBLIC HALL, 1st STORY | Open |
| Oct 15, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 3rd STORY | Open |
| Oct 15, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 1st STORY | Open |
| Oct 5, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS ...DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Oct 5, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES ...DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Oct 5, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ...AT CEILING AT PUBLIC HALL, 3rd STORY | Open |
| Oct 5, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE ...FIRE RETARDANT MATERIAL AT CEILING AT PUBLIC HALL, 3rd STORY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 3, 2026, 5:54 AM ET. BBL 1010370059.