3 floors · 41,260 sq ft · built 1925 · class O5 · owner of record: 3450 East Tremont Realty, Inc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 41,260 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 164 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 164 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 774 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 1, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-381. NOTED: EMERGENCY ILLUMINATED EXIT DISCHARGE LIGHTS AND EXIT SIGNS NOT W #35732709Z | May 29, 2026 POP/IN-VIO | $0 |
| May 1, 2026 | Construction CLASS - 2 EMERGENCY SIGNS AT ELEVATOR CALL STATIONS MISSING, DEFECTIVE OR NON-COMPLIANT WITH SECTION REQUIREMENTS. NOTED: AT 3RD FLOOR ELEVATOR LOBBY WAS MISSING MAP EMERGENCY SIGN OBSERVED UPON INSPECTION. REMEDY: INSTA #35732711H | May 29, 2026 POP/IN-VIO | $0 |
| May 1, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: FIRE RATED CLASSROOMS AND SMOKE DOORS NOT SELF-CLOSING DUE TO MISSING AND/OR FAULTY HARDWARE OR BINDING ON CLASSROOMS 305, 319, 321, E5, E6 OBSERVED #35732708R | May 29, 2026 POP/IN-VIO | $0 |
| May 1, 2026 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. NOTED: EMERGENCY EXTERIOR EXIT DOOR NOT SELF-CLOSING DUE TO BINDING, MISSING AND/OR FAULTY HARDWARE ON 1 OF 3 EXTERIOR STORE FRONT DOOR OBERVED UPON INSPECTION. REMEDY: REPAIR/REPLAC #35732710X | May 29, 2026 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 26, 2020 | ELEVATOR #9027/688469 | DOB VIOLATION - ACTIVE |
| Feb 3, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00049 | DOB VIOLATION - ACTIVE |
| Nov 3, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00059 | DOB VIOLATION - ACTIVE |
| Sep 28, 2019 | ELEVATOR #9027/661592 | DOB VIOLATION - ACTIVE |
| Aug 3, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00312 | DOB VIOLATION - ACTIVE |
| May 3, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00489 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Feb 3, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Nov 3, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Aug 3, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| May 3, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 18, 2026, 10:51 PM ET. BBL 2055310021.