4 floors · 8 apartments · 9,375 sq ft · built 2005 · class C1 · owner of record: Ky 146 Realty, Llc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2024-09-30 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 45 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 45 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 61 days | Annual |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 776 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-08 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 3, 2026 | Construction CLASS - 2 FAILURE TO CERTIFY CORRECTIONS FOR VIOLATION NUMBER 39147056Z, FILE A CERTIFICATE OF CORRECTION #39178993P | May 15, 2026 IN VIOLATION | $1,250 |
| Jan 14, 2026 | Construction CLASS - 1 OBSERVED THROUGHOUT BUILDING SPRINKLER HEADS OBSTRUCTED. PIPE PENETRATING WALLS AND CEILINGS AND NO FIRE STOP IN PLACE. IN BASEMENT GAS BYPASS INSTALLED IN THE LAUNDRY ROOM. PVC PIPING INSTALLED UNDER SINK WHIC #39173842P | Sep 15, 2026 IN VIOLATION | $1,250 |
| Jan 14, 2026 | Construction CLASS - 1 OBSERVED IN THE BASEMENT IN THE LAUNDRY ROOM INSTALLED GAS BYPASS WITHOUT A PERMIT ALL WORK COMPLETED NO PERMITS., OBTAIN PERMIT #39173843R | Sep 15, 2026 IN VIOLATION | $1,250 |
| Jan 14, 2026 | Construction CLASS - 2 OBSERVED THROUGHOUT BUILDING LACKING ESCUTCHEONS ON WATER LINES AND WASTE LINES IN BATHROOMS. TOILET SEATS NOT OPEN ENDED HINGED. USING FERNCO COUPLINGS ON WASTE LINES. OUTSIDE OF BUILDING FRESH AIR PLATE MISSI #39173841N | Sep 15, 2026 IN VIOLATION | $500 |
| Jan 9, 2026 | Boilers CLASS - 2 I FOUND A WILLIAMSON BOILER GWA 07 WITH LOW WATER CUT OFF DISCONNECTED/ BACKFLOW WAS LEAKING/ MISSING FIRE DAMPER ON FRESH AIR/ NEED TO SEAL AROUND FLU PIPE/ CORRECT ALL VIOLATIONS CONDITIONS/ SUBMIT CERTIFICAT #39173164P | Mar 20, 2026 STIPULATION/IN-VIO | $1,250 |
| May 5, 2025 | Construction CLASS - 2 OBSERVED HOLE PENETRATIONS AT 1ST FLOOR IN THE LAUNDRY AREA BEHIND WASHER AND SECURITY OFFICE. NON SELF CLOSING EXIT DOORS IN COMMON AREA THROUGHOUT BUILDING. POTENTIAL FIRE HAZARDS.B OBSERVED NON SELF CLOSING #39147057K | Oct 31, 2025 IN VIOLATION | $625 |
| May 5, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS IN LAUNDRY ROOM AREA AND SECURITY ROOM AREA. POTENTIAL #39147056Z | Dec 4, 2026 PENDING | $2,500 |
| Apr 29, 2025 | Construction CLASS - 2 FAILURE TO CERTIFY CORRECTIONS FOR VIOLATION NUMBER 39087626J, FILE A CERTIFICATE OF CORRECTION #39146418M | Oct 31, 2025 IN VIOLATION | $1,250 |
| Mar 6, 2023 | Boilers CLASS - 2 ELECTRICAL WIRES ON BOILERS, 10, 12, 14 & 15 EXPOSED-PRV DISCHARGE FOR BOILER 18 W/O A DISCHARGE PIPE-BOILER 14 NOT OPERATING TO PROVIDE HEATING. #39080810H | May 19, 2023 ADMIT/IN-VIO | $0 |
| Oct 26, 2021 | Unknown CLASS - 1 I OBSERVED IN THE BASEMENT THE GROUNDING ELECTRODE CONDUCTOR FOR THE WATER METER JUMPER NOT SECURED AND THE GROUND CLAMP INACCESSIBLE AT THE POINT OF CONNECTION TO THE MAIN WATER PIPE., PROPERLY INSTALL GROUND #39049995H | Jan 21, 2022 IN VIOLATION | $0 |
| May 20, 2019 | Unknown CLASS - 1 OBSERVED IN BADSEMENT ELECTRICAL SERVICE AREA THE INSTALLATION OF THE GROUND ELECTRICAL CONDUCTOR FROM THE GROUND CLAMP AROUND THE WALL TO JUMP ACROSS THE WATER METER. THE CONDUCTOR IS EXPRESSIVELY LONG #35422416L | Dec 6, 2019 IN VIOLATION | $0 |
| Aug 13, 2018 | Boilers CLASS - 2 50A.50B.50C.50D-AS PER CLASS 2 (B254)28.301.1 FAILURE TO MAINTAIN.50A:WATER PIPING NOT SUPPORTED.50B:WATER PIPING LEFT UNCAPPED.50C:ELECTRICAL COVER FOR STACK SWITCH MISSING.50D:BACK (FROWDRAIN)NOT PIED DOWN. #32097661J | Nov 2, 2018 DEFAULT | $0 |
| Jul 2, 2018 | Construction CLASS - 1 UNLAWFUL ACTS,FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.IN MARCH 20,2018.A ELECTRICAL VIOLATION WAS ISSUE TO THE RESPONDENT THE RESPONDENT.THE RESPONDENT FAILED TO COMPLY WITH (NYC) ELECTRICAL CODE#25 #35313570R | Feb 8, 2019 IN VIOLATION | $0 |
| Mar 20, 2018 | Unknown CLASS - 1 FAILURE TO INSTALL GROUNDING ELECTRODE CONDUCTOR IN ACCORDANCE WITH SECTION. OBSERVED IN BASEMENT ELECTRICAL SERVICE AREA THE INSTALLATION OF THE GROUND CONDUCTOR FROM THE GROUND CLAMP AROUND THE WALL TO JUMP A #35325179M | Aug 23, 2019 IN VIOLATION | $0 |
| Jan 3, 2017 | Construction CLASS - 3 OCCUPANCY CONTRARY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG. DEPT RECORDS. NOTED: CO#200985577 DATED 10/17/08 MANDATES THAT FLR 1 THRU 4 OCCUPIED AS 2 CLASS'A'APTS. EACH FLOOR AT TIME OF INSPECTION 1ST FL #35214234Y | Feb 17, 2017 IN VIOLATION | $0 |
| Dec 3, 2016 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O. MULTIPLE DWELLING W/CO#200985577F SHOWS 4 STY W/2 CLASS'A'APTS PER FLOOR NOW BEING USED ASA SHELTER W/SRO'S THROUGHOUT EACH FLOOR ILLEGALY. AT TIME OF INSPECTIO #35223025M | Mar 3, 2017 STIPULATION/IN-VIO | $0 |
| Nov 21, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 11/21/16 SPRINKLER HEADS PROTRUDING OUT OF THE CEILING ON MAIN FLOOR ALSO IN BASEMENT. REMEDY: REPAIR & OR REPLACE. #35221665L | Feb 17, 2017 IN VIOLATION | $0 |
| Apr 25, 2011 | Construction CLASS - 2 WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS & OR APPROVED AMENDMENTS FOR ALT 2 JOB #220099541 OF WHICH APPLICATION OF RECORD IS REQUESTING A LETTERS OF COMPLETION. NON-CONFORMING WORK NOTED: OBSEVE #34884813P | Jun 17, 2011 STIPULATION/IN-VIO | $0 |
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 22, 2024 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Nov 17, 2025 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| May 8, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 11, 2026 |
| Jun 13, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 16, 2025 |
| Jan 24, 2025 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Jan 30, 2025 |
| Aug 13, 2018 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM .. AT PUBLIC HALL, 1st STORY | Aug 21, 2018 |