Bronx · Block 2329 · Lot 93 · 10451

345 East 146 Street

4 floors · 8 apartments · 9,375 sq ft · built 2005 · class C1 · owner of record: Ky 146 Realty, Llc.

23open violations
$9,875ECB/OATH penalties owed
2HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2024-09-30
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 45 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 45 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 61 days
Annual
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 776 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-08 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (18) · $9,875 owed
IssuedViolationHearingBalance
Mar 3, 2026Construction CLASS - 2
FAILURE TO CERTIFY CORRECTIONS FOR VIOLATION NUMBER 39147056Z, FILE A CERTIFICATE OF CORRECTION
#39178993P
May 15, 2026
IN VIOLATION
$1,250
Jan 14, 2026Construction CLASS - 1
OBSERVED THROUGHOUT BUILDING SPRINKLER HEADS OBSTRUCTED. PIPE PENETRATING WALLS AND CEILINGS AND NO FIRE STOP IN PLACE. IN BASEMENT GAS BYPASS INSTALLED IN THE LAUNDRY ROOM. PVC PIPING INSTALLED UNDER SINK WHIC
#39173842P
Sep 15, 2026
IN VIOLATION
$1,250
Jan 14, 2026Construction CLASS - 1
OBSERVED IN THE BASEMENT IN THE LAUNDRY ROOM INSTALLED GAS BYPASS WITHOUT A PERMIT ALL WORK COMPLETED NO PERMITS., OBTAIN PERMIT
#39173843R
Sep 15, 2026
IN VIOLATION
$1,250
Jan 14, 2026Construction CLASS - 2
OBSERVED THROUGHOUT BUILDING LACKING ESCUTCHEONS ON WATER LINES AND WASTE LINES IN BATHROOMS. TOILET SEATS NOT OPEN ENDED HINGED. USING FERNCO COUPLINGS ON WASTE LINES. OUTSIDE OF BUILDING FRESH AIR PLATE MISSI
#39173841N
Sep 15, 2026
IN VIOLATION
$500
Jan 9, 2026Boilers CLASS - 2
I FOUND A WILLIAMSON BOILER GWA 07 WITH LOW WATER CUT OFF DISCONNECTED/ BACKFLOW WAS LEAKING/ MISSING FIRE DAMPER ON FRESH AIR/ NEED TO SEAL AROUND FLU PIPE/ CORRECT ALL VIOLATIONS CONDITIONS/ SUBMIT CERTIFICAT
#39173164P
Mar 20, 2026
STIPULATION/IN-VIO
$1,250
May 5, 2025Construction CLASS - 2
OBSERVED HOLE PENETRATIONS AT 1ST FLOOR IN THE LAUNDRY AREA BEHIND WASHER AND SECURITY OFFICE. NON SELF CLOSING EXIT DOORS IN COMMON AREA THROUGHOUT BUILDING. POTENTIAL FIRE HAZARDS.B OBSERVED NON SELF CLOSING
#39147057K
Oct 31, 2025
IN VIOLATION
$625
May 5, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS IN LAUNDRY ROOM AREA AND SECURITY ROOM AREA. POTENTIAL
#39147056Z
Dec 4, 2026
PENDING
$2,500
Apr 29, 2025Construction CLASS - 2
FAILURE TO CERTIFY CORRECTIONS FOR VIOLATION NUMBER 39087626J, FILE A CERTIFICATE OF CORRECTION
#39146418M
Oct 31, 2025
IN VIOLATION
$1,250
Mar 6, 2023Boilers CLASS - 2
ELECTRICAL WIRES ON BOILERS, 10, 12, 14 & 15 EXPOSED-PRV DISCHARGE FOR BOILER 18 W/O A DISCHARGE PIPE-BOILER 14 NOT OPERATING TO PROVIDE HEATING.
#39080810H
May 19, 2023
ADMIT/IN-VIO
$0
Oct 26, 2021Unknown CLASS - 1
I OBSERVED IN THE BASEMENT THE GROUNDING ELECTRODE CONDUCTOR FOR THE WATER METER JUMPER NOT SECURED AND THE GROUND CLAMP INACCESSIBLE AT THE POINT OF CONNECTION TO THE MAIN WATER PIPE., PROPERLY INSTALL GROUND
#39049995H
Jan 21, 2022
IN VIOLATION
$0
May 20, 2019Unknown CLASS - 1
OBSERVED IN BADSEMENT ELECTRICAL SERVICE AREA THE INSTALLATION OF THE GROUND ELECTRICAL CONDUCTOR FROM THE GROUND CLAMP AROUND THE WALL TO JUMP ACROSS THE WATER METER. THE CONDUCTOR IS EXPRESSIVELY LONG
#35422416L
Dec 6, 2019
IN VIOLATION
$0
Aug 13, 2018Boilers CLASS - 2
50A.50B.50C.50D-AS PER CLASS 2 (B254)28.301.1 FAILURE TO MAINTAIN.50A:WATER PIPING NOT SUPPORTED.50B:WATER PIPING LEFT UNCAPPED.50C:ELECTRICAL COVER FOR STACK SWITCH MISSING.50D:BACK (FROWDRAIN)NOT PIED DOWN.
#32097661J
Nov 2, 2018
DEFAULT
$0
Jul 2, 2018Construction CLASS - 1
UNLAWFUL ACTS,FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER.IN MARCH 20,2018.A ELECTRICAL VIOLATION WAS ISSUE TO THE RESPONDENT THE RESPONDENT.THE RESPONDENT FAILED TO COMPLY WITH (NYC) ELECTRICAL CODE#25
#35313570R
Feb 8, 2019
IN VIOLATION
$0
Mar 20, 2018Unknown CLASS - 1
FAILURE TO INSTALL GROUNDING ELECTRODE CONDUCTOR IN ACCORDANCE WITH SECTION. OBSERVED IN BASEMENT ELECTRICAL SERVICE AREA THE INSTALLATION OF THE GROUND CONDUCTOR FROM THE GROUND CLAMP AROUND THE WALL TO JUMP A
#35325179M
Aug 23, 2019
IN VIOLATION
$0
Jan 3, 2017Construction CLASS - 3
OCCUPANCY CONTRARY CONTRARY TO THAT ALLOWED BY THE C OF O OR BLDG. DEPT RECORDS. NOTED: CO#200985577 DATED 10/17/08 MANDATES THAT FLR 1 THRU 4 OCCUPIED AS 2 CLASS'A'APTS. EACH FLOOR AT TIME OF INSPECTION 1ST FL
#35214234Y
Feb 17, 2017
IN VIOLATION
$0
Dec 3, 2016Construction CLASS - 2
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O. MULTIPLE DWELLING W/CO#200985577F SHOWS 4 STY W/2 CLASS'A'APTS PER FLOOR NOW BEING USED ASA SHELTER W/SRO'S THROUGHOUT EACH FLOOR ILLEGALY. AT TIME OF INSPECTIO
#35223025M
Mar 3, 2017
STIPULATION/IN-VIO
$0
Nov 21, 2016Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. OBSERVED ON 11/21/16 SPRINKLER HEADS PROTRUDING OUT OF THE CEILING ON MAIN FLOOR ALSO IN BASEMENT. REMEDY: REPAIR & OR REPLACE.
#35221665L
Feb 17, 2017
IN VIOLATION
$0
Apr 25, 2011Construction CLASS - 2
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS & OR APPROVED AMENDMENTS FOR ALT 2 JOB #220099541 OF WHICH APPLICATION OF RECORD IS REQUESTING A LETTERS OF COMPLETION. NON-CONFORMING WORK NOTED: OBSEVE
#34884813P
Jun 17, 2011
STIPULATION/IN-VIO
$0
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (6) · C 2 · B 0 · A 2
IssuedClassViolationCorrect by
Nov 22, 2024I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Nov 17, 2025I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
May 8, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 11, 2026
Jun 13, 2025A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Sep 16, 2025
Jan 24, 2025C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOMJan 30, 2025
Aug 13, 2018C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM .. AT PUBLIC HALL, 1st STORYAug 21, 2018

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 16, 2026, 10:02 PM ET. BBL 2023290093.

Look up another building