Bronx · Block 3327 · Lot 132 · 10467

3433 Dekalb Avenue

6 floors · 84 apartments · 89,250 sq ft · built 1927 · class D7 · owner of record: Nuva Realty, Llc

302open violations
$85,625ECB/OATH penalties owed
142HPD class C (immediately hazardous)
61dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 61 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 61 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 77 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 89,250 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 182 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 182 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 305 days
Registered through 2027-09-01
Energy audit and retro-commissioning (2027) Likely applies
Local Law 87 · Calendar year 2027
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3327). Agency page

Dec 31, 2027
in 426 days
Next due 2027
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1157 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-21 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (29) · $85,625 owed
IssuedViolationHearingBalance
Aug 20, 2026Construction CLASS - 1
WORK WITHOUT A PERMIT. AT TIME OF INSPECTION OBSERVED NO PERMIT FOR WORK BEING DONE. CONSTRUCTION WORK, NEW SECTIONS OF WALL PUT UP ON BASEMENT MAKING 4 SRO'S WOTH BATHROOM AND SMALL KITCHEN. REMEDY: OBTAIN PER
#35721722J
Oct 30, 2026
PENDING
$2,500
Aug 20, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. LACK OF REQUIRED NUMBER OF MEANS OF EGRESS FOR EVERY FLOOR PER BC 1018.1(2008 CODE) 27-366 BC 1021.1(2014 CODE); BC 1006.3(2002 CODE). AT TIME OF INSPECTIO
#35728166J
Oct 30, 2026
PENDING
$2,500
Aug 20, 2026Quality of Life CLASS - 1
ILLEGAL OCCUPANCY WITH 3 OR MORE ADDITIONAL DWELLING UNITS. CELLAR LEVEL FIRST ROOM IN HALLWAY, SRO MADE WITH BED CLOTHING, KEY LOCK ON DOORNUMBERES # ON DOOR. REMEDY: RESTORE TO PRIOR LEGAL CONDITION.
#35728161K
Oct 30, 2026
PENDING
$15,000
Aug 20, 2026Construction CLASS - 1
WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, OBSERVED NO PERMITS ON FILE FOR WORK BEING DONE IN BUILDING, ELECTRICAL WORK DONE FOR 4 SRO'S FOR NEW LIGHTS/OUTLETS. REMEDY: OBTAIN WORK PERMITS.
#35721724N
Oct 30, 2026
PENDING
$2,500
Aug 20, 2026Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING RECORDS. AT TIME OF INSPECTION, OBSERVED DEPARTMENT RECORDS AND HPD 1 CARD SHOW 82 UNITS. OBSERVED 4 SRO AT CELLAR LEVEL. REMEDY: D
#35728165H
Oct 30, 2026
PENDING
$2,500
Aug 20, 2026Quality of Life CLASS - 1
ILLEGAL OCCUPANCY WITH 3 OR MORE ADDITIONAL DWELLING UNITS. AT TIME OFINSPECTION OBSERVED CELLAR LEVEL 2ND SRO MADE WITH BED, FOOD, CLOTHINGAND KEY LOCK ON DOOR(DOOR NUMBERED #2). REMEDY: RESTORE TO PRIOR LEGAL
#35728162M
Oct 30, 2026
PENDING
$15,000
Aug 20, 2026Quality of Life CLASS - 1
ILLEGAL OCCUPANCY WITH 3 OR MORE ADDITIONAL DWELLING UNITS. AT TIME OFINSPECTION OBSERVED CELLAR LEVEL LAST ROOM(#4) SRO MADE WITH BED, FOOD, CLOTHING, KEY LOCK ON DOOR. REMEDY: RESTORE TO PRIOR LEGAL CONDITION
#35728164X
Oct 30, 2026
PENDING
$15,000
Aug 20, 2026Construction CLASS - 1
WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, OBSERVED NO PERMITS ON FILE FOR WORK BEING DONE ON BASEMENT. FOUR NEW WATER LINES FOR BATHROOMAND KITCHEN, ALSO A LAUNDRY INSTALLED WITH NEW WATER LINES. REMEDY: OB
#35721723L
Oct 30, 2026
PENDING
$2,500
Aug 20, 2026Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED SRO ON CELLAR LEVEL LACK OF AIR VENTILATION AND LACK OF LIGHT EXPOSURE. REMEDY: REPAIR/REPLACE.
#35728167L
Oct 30, 2026
PENDING
$2,500
Aug 20, 2026Quality of Life CLASS - 1
ILLEGAL OCCUPANCY WITH 3 OR MORE ADDITIONAL DWELLING UNITS. AT TIME OFINSPECTION OBSERVED CELLAR LEVEL ROOM 3 SRO MADE WITH BED, FOOR, CLOTHS, KEY LOCK ON DOOR(DOOR NUMBERED #3 ON IT). REMEDY: RESTORE TO PRIOR
#35728163Y
Oct 30, 2026
PENDING
$15,000
Oct 21, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES.NOTE:AT TIME OF INSPECTION I OBSERVED EXP#1 EAST CRACKED WATER TABLE ABOVE 1ST FLMULTI LOC.2 BROKEN WINDOW ONE ON THE 6TH FL AT THE SOUTHERN MUST SETBA
#35717911R
Oct 23, 2026
PENDING
$5,000
Apr 22, 2019Elevators CLASS - 2
52M15,05J10,03I10,78H14,71X10,42B09,57M07,46M07,35M07;52-M=PROVIDE ANDTAG DEVICE,05-J=GAP ON RETURN POST REPAIR,03-I=REPAIR RUSTED DAMAGED POST STRIKE SIDE,78-H=SHORTEN ROPE,71-X=REPAIR PIT LIGHT,42-B=REMOVE WI
#38269270Z
Aug 9, 2019
IN VIOLATION
$625
May 10, 2018Cranes and Derricks CLASS - 2
PARTIAL SWO ISSUED FOR SUSPENDED SCAFFOLD PURSUANT 28-207.2 & POSTED ON PREMISES. FAILURE TO NOTIFY DEPT 24 HOUR PRIOR TO SUSPENDED SCAFFOLD INSTALLATION. NOTED: @ TIME OF INSP SUSPENDED SCAFFOLD IN CONNECTION
#35323838H
Jun 29, 2018
DEFAULT
$5,000
Jan 17, 2018Cranes and Derricks CLASS - 2
FAILURE TO NOTIFY DEPT 24HRS PRIOR TO REMOVAL OF SUSPENDED SCAFFOLD. NOTED: AT TIME OF INSPECTION SUSPENDED SCAFFOLDS WERE REMOVED W/O PRIOR NOTIFYING DEPT. REMEDY: NOTIFY DEPT 24HRS PRIOR TO SUSPENDED SCAFFOLD
#35285663K
Apr 13, 2018
IN VIOLATION
$0
Jan 17, 2018Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING. NOTED: AT TIME OF INSPECTION CONTRUCTION DEBRIS ARE FILED UP ON THE FRONT YARD OF THE BLDG. THIS CONDITION POSES POTENTIAL HAZARD TO THE PEOPLE EHO RESIDE AT THE 1ST
#35285661R
Mar 30, 2018
WRITTEN OFF
$0
Oct 28, 2014Elevators CLASS - 2
03V01,67X10,16B07,42E10,56Y10,69B07,83B07,71I11,96B07,39O02,34O02,37O02,70O02. 03V01-CAR FLOOR STOPS OUT ON EX( ) LEVEL MUST ADJUST; 67X10- COMMUNICATION INOPERATIVE; 16B07-HOISTWAY DOORS BRAILLE TAGS MISSING
#38233563H
Mar 20, 2015
WRITTEN OFF
$0
May 29, 2014Elevators CLASS - 1
97X10. FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER SERVICE EQUIPMENT- ELEVATOR A/P BC3001.2 & 27-987 DOB RECORDS SHOW THE ONLY ELEV IN BLDG AS ACTIVE. UPON INSP THE DEVICE IS FOUND TO BE OUT OF SERVICE CREAT
#38231605H
Jul 18, 2014
WRITTEN OFF
$0
Dec 3, 2010Elevators CLASS - 1
CU32-H-10/05-L-10/12-Q-03/37-D-06/37-T-07/37-X-10/20-M-10/41-D-06/41-T-07/CU-32-CAR GUIDE SHOES ARE BADLY WORN,ELEVATOR CLIPPING RAIL BRACKETS IN HOISTWAY.05-CAR DOOR NOT CLOSING FULLY.37-PROVIDE LOCK FOR DOOR
#38213871L
Feb 4, 2011
WRITTEN OFF
$0
Aug 18, 2010Elevators CLASS - 1
CEASE USE 20/M/7CEASE USE76/E/10, 12/Q/7,16/H/11,41/T/7,58/X/10,60/Q/7,61/T/7,97/X/10-20-M-7-MISSING VISION,PANEL & BOARD/76-E-10-DEVICE ON SAFETY, RESET SAFATIES TO LIFT CEASE USE CALL 212-566-5544/16-H-11-TOP
#38212287H
Mar 25, 2011
WRITTEN OFF
$0
Jun 23, 2010Boilers CLASS - 2
B254,50.
#32068719K
Oct 12, 2010
IN VIOLATION
$0
May 4, 2010Elevators CLASS - 2
08V10,21Q03,16L10,21L10,37I10,37O07,37X10,12Q0,70O02,10H10,42E10: 21 4TH FLOOR INTERLOCK COVER MISSING. 16/21 PULL ON 4TH FLOOR STORS ELEVATION FLIGHT. 37 REPAIR DOOR AND PROVIDE LOCK. 37X WORK LIGHTING, 42 LUB
#38210557J
Jul 2, 2010
IN VIOLATION
$0
Aug 5, 2009Elevators CLASS - 2
16L10,21L10,14M07,12Q03,37D06,37X10,37T07,58F10,17L10,98U05,44D06. 16/21L10- 2ND FL HOISTWAY DOOR & INTERLOCK DEFECTIVE CAUSING ELEVATOR TO GET STUCK. 37D06- NO LOCK ON DOOR. 37X10- WORK LIGHT INOPERATIVE.
#38204848Z
Oct 2, 2009
DEFAULT
$0
Jun 12, 2009Elevators CLASS - 2
05J1012Q0314M1070O0298U0558F1041D0637X1041T07. 05J10 EXCESSIVE GAP AT RETURN POST. 12Q03 PROVIDE COVER FOR CAR LIGHTING. 37X10 REPAIR OVERHEAD LIGHTING.
#38202770Z
Aug 7, 2009
STIPULATION/IN-VIO
$0
Feb 9, 2009Elevators CLASS - 2
14M10.10H10.05J10.37D06.37X10.08V10.41D06.70O02.40M07.10M07 IN CAB SAFETY MIRROR MISSING 05J10 REPAIR EXCESSIVE CAB BY RETURN POST 37D06 PROVIDE LOCK 37X10 OVERHEAD WORK LIGHTS 40M07 ELEVATOR CO MAINTENACE LOG
#38200605X
Jul 24, 2009
DEFAULT
$0
Sep 15, 2008Elevators CLASS - 2
97X10.97X10.ONLY ELEVATOR IN BLDG OUT OF SERVICE RESTORE TO SERVICE
#38190374L
Mar 20, 2009
IN VIOLATION
$0
Sep 8, 2008Elevators CLASS - 2
23X10.08V10.42E10.37D06.41D06.37X10.14M10.98U05.23X10 ELEVATOR NOT RESPONDING TO ANY HALL CALL BUTTON 37X10 WORK LIGHTS 08V10 REPAIR ALL UP DIRECTIONAL FL STPS 42E10 ELIMINATE EXESSIVE SELECTOR TAPE SHEAVE NOIS
#38190369R
Dec 8, 2008
IN VIOLATION
$0
May 5, 2008Elevators Non-Hazardous
57F10.36D06.41E10.33O02.40D06. 57 REPAIR EXCESSIVE BACK CASH 36 PROVIDE LOCK 41 SELECTOR SHEAVE & TAPE 40 PROVIDE LOCK
#38184205J
May 1, 2009
IN VIOLATION
$0
Aug 20, 2007Elevators Non-Hazardous
12Q03,23X10,37Q03,36T07,36I10,36X10,40T07,59Q03,71Q03,86BB05.12Q03-INSTALL GUARDS FOR CAR LIGHT.23X10-REPAIR HALL BUTTON INDICATOR.INSTALL COVER TO JUNCTION BOXES IN SHAFTWAY.36T07- PROVIDE SIGN FOR OVERHEAD
#38169251P
Oct 5, 2007
STIPULATION/IN-VIO
$0
Aug 18, 2003Elevators Non-Hazardous
55Y13,55O2,41Q3,16B1,57H10,12Q3,2B144B10,23I10,66O2. 16- BASEMENT DOOR. 44 GOV MAKING NOISES. 23 LOBBY
#38140116N
Oct 3, 2003
DEFAULT
$0
DOB (18)
IssuedViolationStatus
Aug 20, 2026CONSTRUCTION
EMERGENCY WORK ORDER.MASONRY&WOOD FRAMED FLOORS THAT SUSTAINED DAMAGE DUE TO FIRE ON 08/20/26.SEVERE DAMAGE @ ROOF & J,K,L,M&N LINES@C WING, PARTIALLY OPEN @ C WING W/SEVERELY DAMAGED ROOF FRAME.OWNER TO HIRE NYSPE,DEMO ENDORSED GC & ASBESTOS CONT'R TO IMMED SUBMIT MEANS & METHODS BY 8/22/26
#FEU20702BP
DOB VIOLATION - ACTIVE
Aug 20, 2026CONSTRUCTION
STRUCTURE RENDERED NON-COMPLIANT. DUE TO FIRE THAT STARTED 6M BECAUSE OF INTERIOR WIRING AT CEILING ARCING AND CASUE FIRE TO CATCH AND WENT THROUGH COCKLOFT AND SPREADED TO MOST C AND B WINGS. HEAVY FIRE, SMOKE AND WATER DAMAGE, AFFECTING 6TH FLOOR. WHOLE BUILDING , PRIMARY ENTRANCE IS COMPRIMISED.
#26-02066
DOB VIOLATION - ACTIVE
Aug 20, 2026CONSTRUCTION
EMERGENCY WORK ORDER.FLRS THAT SUSTAIND DMGD DUE TO FIRE ON 08/20/26 SEVERE DMGD@ROOF@J,K,L,M,&N LINES.OPEN ROOF@"B"WING(A,B,C,H)LINES WATER DMG@"B"&"C" WINGS."A"WING PRIMARY EGRESS AFFECTD AS IT PSSE IMMED RESTORE PRIMARY EGRESS FOR "A"WING(D,E,F,&G)LINES.1.SEAL ALL ROOF OPENINGS@"B"WING,2.INSTLL T
#FEU20701BP
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#14495
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#35440
DOB VIOLATION - ACTIVE
Nov 8, 2019LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
#03747
DOB VIOLATION - ACTIVE
Sep 6, 2019(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
#03961
DOB VIOLATION - ACTIVE
Apr 18, 2018FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00214
DOB VIOLATION - ACTIVE
Nov 14, 2016(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST
#05576
DOB VIOLATION - ACTIVE
May 2, 2015FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00678
DOB VIOLATION - ACTIVE
Oct 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
#01892
DOB VIOLATION - ACTIVE
Aug 27, 2014FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00099
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#08840
DOB VIOLATION - ACTIVE
Mar 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
#03305
DOB VIOLATION - ACTIVE
Oct 1, 2012ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST
#02155
DOB VIOLATION - ACTIVE
Dec 13, 2011ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST
#02337
DOB VIOLATION - ACTIVE
Feb 23, 2011FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00122
DOB VIOLATION - ACTIVE
Dec 2, 2010FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00677
DOB VIOLATION - ACTIVE
DOB NOW Safety (18)
IssuedViolationStatus
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 7)
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 8, 2019Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Active
Sep 6, 2019Elevators ACC1
Active
May 20, 2019Elevators EVCAT5
Active
Apr 18, 2018AEUHAZ FTC-AEU-HAZ
Active
Nov 14, 2016Elevators ACC1
Active
May 2, 2015Benchmarking - LL84 FTF-EN-BENCH
Active
Oct 31, 2014Elevators EVCAT1
Active
Aug 27, 2014AEUHAZ FTC-AEU-HAZ
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
Mar 31, 2014Elevators EVCAT1
Active
Oct 1, 2012Elevators EVCAT1
Active
Dec 13, 2011Elevators EVCAT1
Active
Feb 23, 2011AEUHAZ FTC-AEU-HAZ
Active
Dec 2, 2010AEUHAZ FTC-AEU-HAZ
Active
HPD (238) · C 142 · B 72 · A 23
IssuedClassViolationCorrect by
Aug 25, 2026I§ 27-2089 ADM CODE THE PREMISES HAVE BEEN VACATED BY AN ORDER OF THIS DEPARTMENT AND CANNOT BE REOCCUPIED EXCEPT FOR CARETAKER, UNTIL (1) AN APPLICATION AND PLAN FOR THE WORK REQUIRED BY THIS ARTICLE HAVE BEEN FILED WITH AND APPROVED BY THE DEPARTMENT OF BUILDINGS, WHERE REQUIRED, (2) SUCH WORK HAS —
Sep 18, 2026B§ 27-2005 ADM CODE PROVIDE HANDSET AT EXTERIOR OF BULKHEAD DOOR AT ROOF THAT ALLOW UNOBSTRUCTED REENTRY FROM ROOF TO PUBLIC HALL STAIRS AT PUBLIC HALL STAIRS, 6th STORY, SECTION AT SOUTHOct 23, 2026
Sep 18, 2026CApt 1A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER GLASS PANE AT 1ST WINDOW FROM WEST AT NORTH IN THE 2nd ROOM FROM EAST LOCATED AT APT 1A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHSep 24, 2026
Sep 18, 2026CApt 1B · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHSep 24, 2026
Sep 18, 2026BApt 1H · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 1H, 1st STORY, 2nd APARTMENT FROM SOUTH AT WESTOct 23, 2026
Sep 18, 2026CApt 1H · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1H, 1st STORY, 2nd APARTMENT FROM SOUTH AT WESTSep 24, 2026
Sep 3, 2026CApt 3G · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTSep 9, 2026
Sep 3, 2026CApt 4E · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4E, 4th STORY, 8th APARTMENT FROM NORTH AT EASTSep 9, 2026
Sep 3, 2026CApt 5E · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 8th APARTMENT FROM NORTH AT EASTSep 9, 2026
Sep 3, 2026CApt 5F · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTHSep 9, 2026
Sep 3, 2026CApt 5G · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5G, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTSep 9, 2026
Sep 3, 2026CApt 1G · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTSep 9, 2026
Sep 3, 2026CApt 1F · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTHSep 9, 2026
Sep 3, 2026CApt 4G · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTSep 9, 2026
Sep 3, 2026CApt 2E · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2E, 2nd STORY, 8th APARTMENT FROM NORTH AT EASTSep 9, 2026
Sep 3, 2026CApt 2F · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2F, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHSep 9, 2026
Sep 3, 2026CApt 3E · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 8th APARTMENT FROM NORTH AT EASTSep 9, 2026
Sep 3, 2026CApt 3F · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHSep 9, 2026
Sep 1, 2026CApt 1A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 4th APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 5D · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5D, 5th STORY, 7th APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 3C · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY, 6th APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 5J · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER DAMAGE AT CEILING AND WALLS DUE TO A RECENT FIRE IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 4th APARTMENT FROM SOUTH AT WESTSep 7, 2026
Sep 1, 2026CApt 5J · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANEL AT UPPER AND LOWER SASHES AT 1ST AND 2ND WINDOWS FROM SOUTH AT WEST WALL LEADING TO FIRE ESCAPE IN THE 1st ROOM FROM NORTH LOCATED AT APT 5J, 5th STORY, 4th APARTMENT FROM SOUTH AT WESTSep 7, 2026
Sep 1, 2026CApt 5J · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5J, 5th STORY, 4th APARTMENT FROM SOUTH AT WESTSep 7, 2026
Sep 1, 2026CApt 5K · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5K, 5th STORY, 1st APARTMENT FROM WEST AT NORTHSep 7, 2026
Sep 1, 2026CApt 4A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4A, 4th STORY, 4th APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 4C · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE AT CEILING AND WALLS DUE TO A RECENT FIRE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 6th APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 4C · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4C, 4th STORY, 6th APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 4D · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4D, 4th STORY, 7th APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 4F · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4F, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHSep 7, 2026
Sep 1, 2026CApt 4I · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4I, 4th STORY, 3rd APARTMENT FROM SOUTH AT WESTSep 7, 2026
Sep 1, 2026CApt 4J · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4J, 4th STORY, 4th APARTMENT FROM SOUTH AT WESTSep 7, 2026
Sep 1, 2026CApt 4L · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE AT CEILING AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 4L · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING, WALL OUTLETS AND LIGHT SWITCHES IN THE ENTIRE APARTMENT LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 4L · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4L, 4th STORY, 1st APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 4M · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE AT CEILING AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 4M, 4th STORY, 2nd APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 4M · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING, WALL OUTLETS AND LIGHT SWITCHES IN THE ENTIRE APARTMENT LOCATED AT APT 4M, 4th STORY, 2nd APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 4M · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4M, 4th STORY, 2nd APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 3B · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3B, 3rd STORY, 5th APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 3D · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3D, 3rd STORY, 7th APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 3D · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER DAMAGE AT CEILING AND WALLS DUE TO A RECENT FIRE IN THE ENTIRE APARTMENT LOCATED AT APT 3D, 3rd STORY, 7th APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 3D · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT ENTRY DOOR AT ROOM WITH THE FIRE ESCAPE WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 3D, 3rd STORY, 7th APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 3J · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER DAMAGE AT CEILING AND WALLS DUE TO A RECENT FIRE IN THE ENTIRE APARTMENT LOCATED AT APT 3J, 3rd STORY, 4th APARTMENT FROM SOUTH AT WESTSep 7, 2026
Sep 1, 2026AApt 3J · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISITING OF WOOD STUD AND SHEETROCK WALLS ERECTED FROM FLOOR TO CEILING CREATING AN ADDITIONAL ROOM IN THE 3rd ROOM FROM NORTH AT WEST LDec 5, 2026
Sep 1, 2026CApt 3J · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3J, 3rd STORY, 4th APARTMENT FROM SOUTH AT WESTSep 7, 2026
Sep 1, 2026CApt 3N · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING, WALL OUTLETS, AND LIGHT SWITCHES IN THE ENTIRE APARTMENT LOCATED AT APT 3N, 3rd STORY, 3rd APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 3N · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3N, 3rd STORY, 3rd APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 2D · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2D, 2nd STORY, 7th APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026AApt 2D · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF WOOD STUD AND SHEETROCK WALLS ERECTED FROM FLOOR TO CEILING CREATED AN ADDITIONAL ROOM IN THE 1st ROOM FROM EAST AT NORTH LOCDec 5, 2026
Sep 1, 2026CApt 2G · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTSep 7, 2026
Sep 1, 2026CApt 2J · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER DAMAGE AT CEILING AND WALLS DUE TO A RECENT FIRE IN THE ENTIRE APARTMENT LOCATED AT APT 2J, 2nd STORY, 4th APARTMENT FROM SOUTH AT WESTSep 7, 2026
Sep 1, 2026CApt 2J · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2J, 2nd STORY, 4th APARTMENT FROM SOUTH AT WESTSep 7, 2026
Sep 1, 2026CApt 2K · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER DAMAGE AT CEILING AND WALLS DUE TO A RECENT FIRE IN THE ENTIRE APARTMENT LOCATED AT APT 2K, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHSep 7, 2026
Sep 1, 2026CApt 2K · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2K, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHSep 7, 2026
Sep 1, 2026CApt 2K · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING, WALL OUTLETS AND LIGHT SWITCHES IN THE ENTIRE APARTMENT LOCATED AT APT 2K, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHSep 7, 2026
Sep 1, 2026CApt 2L · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE AT CEILING AND WALLS DUE TO A RECENT FIRE IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 2L · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 2N · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER DAMAGE AT CEILING AND WALLS DUE TO A RECENT FIRE IN THE ENTIRE APARTMENT LOCATED AT APT 2N, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 2N · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2N, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTSep 7, 2026
Sep 1, 2026CApt 1J · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER DAMAGE AT CEILING AND WALLS DUE TO A RECENT FIRE IN THE ENTIRE APARTMENT LOCATED AT APT 1J, 1st STORY, 4th APARTMENT FROM SOUTH AT WESTSep 7, 2026

Showing 60 of 238. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Sep 18, 2026HPD B§ 27-2005 ADM CODE PROVIDE HANDSET AT EXTERIOR OF BULKHEAD DOOR AT ROOF THAT ALLOW UNOBSTRUCTED REENTRY FROM ROOF TO PUBLIC HALL STAIRS AT PUBLIC HALL STAIRS, 6th STORY, SECTION AT SOUTHOpen
Sep 18, 2026HPD C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER GLASS PANE AT 1ST WINDOW FROM WEST AT NORTH IN THE 2nd ROOM FROM EAST LOCATED AT APT 1A, 1st STORY, 2nd APARTMENT FROM WEST AT NORTHOpen
Sep 18, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 18, 2026HPD B§ 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 1H, 1st STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Sep 18, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1H, 1st STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Sep 3, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3G, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Sep 3, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4E, 4th STORY, 8th APARTMENT FROM NORTH AT EASTOpen
Sep 3, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5E, 5th STORY, 8th APARTMENT FROM NORTH AT EASTOpen
Sep 3, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 3, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5G, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Sep 3, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Sep 3, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 2nd APARTMENT FROM EAST AT SOUTHOpen
Sep 3, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Sep 3, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2E, 2nd STORY, 8th APARTMENT FROM NORTH AT EASTOpen
Sep 3, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2F, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 3, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 8th APARTMENT FROM NORTH AT EASTOpen
Sep 3, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 1, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 4th APARTMENT FROM NORTH AT EASTOpen
Sep 1, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5D, 5th STORY, 7th APARTMENT FROM NORTH AT EASTOpen
Sep 1, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY, 6th APARTMENT FROM NORTH AT EASTOpen
Sep 1, 2026HPD C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER DAMAGE AT CEILING AND WALLS DUE TO A RECENT FIRE IN THE ENTIRE APARTMENT LOCATED AT APT 5J, 5th STORY, 4th APARTMENT FROM SOUTH AT WESTOpen
Sep 1, 2026HPD C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GLASS PANEL AT UPPER AND LOWER SASHES AT 1ST AND 2ND WINDOWS FROM SOUTH AT WEST WALL LEADING TO FIRE ESCAPE IN THE 1st ROOM FROM NORTH LOCATED AT APT 5J, 5th STORY, 4th APARTMENT FROM SOUTH AT WESTOpen
Sep 1, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5J, 5th STORY, 4th APARTMENT FROM SOUTH AT WESTOpen
Sep 1, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 5K, 5th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Sep 1, 2026HPD C§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 4A, 4th STORY, 4th APARTMENT FROM NORTH AT EASTOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 31, 2026, 1:49 AM ET. BBL 2033270132.

Look up another building