7 floors · 37,726 sq ft · built 1926 · class H3 · owner of record: Brisam Clinton Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 46 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 37,726 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 167 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 167 days | Annual filing |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $656,000 in late-filing or failure-to-file penalties. Agency page | On file | Cycle 10 filing on record: SWARMP (2025-12-10) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 27, 2026 | Unknown CLASS - 1 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN THE LOBBY FLEX CORDS PASSING ON THE FLOOR COVED BY CARDBOARD, THE BODY SCANNER CORD STA #39202191K | Dec 17, 2026 PENDING | $1,600 |
| Aug 27, 2026 | Construction CLASS - 1 AT THE TIME OF INSPECTION OBSERVED THROUGHOUT THE BUILDING IN STORAGE ROOMS BOXES STACKED TO THE CEILING BLOCKING OPERATION OF SIDE WALL SPRINKLER HEADS CONTRARY TO BC 903.3.3, REPAIR AND/REPLACE #39202203Z | Dec 17, 2026 | $2,500 |
| Aug 27, 2026 | Construction CLASS - 1 ATOIOBSERVED PLASTIC PVC PIPING BEING USED FOR DRAINAGE UNDER 2 COMPARTMENT SINK WITH NO TRAP INSTALLED HAVING PVC FLEXIBLE PIP DRAINING INTO A NO HUB REDUCING FITTING CONTRARY TO . PC 1002.1 & PC 706.1 ALL FIX #39202205M | Dec 17, 2026 PENDING | $2,500 |
| Aug 27, 2026 | Unknown CLASS - 1 FAILURE TO GROUND ELECTRICAL SYSTEMS. OBSERVED IN THE BASEMENT MAIN BUILDING WATER GROUND CLAMP IS RUSTED AND BROKEN AT THE BOLT THE GROUND WIRE IS OXIDIZE. GROUND CLAMP MUST MAINTAIN CONTIUNITY TO PROTECT ELEC #39202190Z | Dec 17, 2026 PENDING | $4,800 |
| Aug 27, 2026 | Construction CLASS - 1 AT THE TIME OF INSPECTION OBSERVED 3 NEW HOT WATER HEATERS INSTALLED WITH OUT PERMITS CHECKED BIS/DOBNOW NO PERMITS ON FILE THE BUILDING PD SAID WASNT AWARE HE NEEDED PERMITS ALL WORK NEEDS PERMIT AND MUST BE D #39202204K | Dec 17, 2026 PENDING | $2,500 |
| Nov 18, 2025 | Elevators CLASS - 2 CLASS 2: CAR RE-LEVELING WITH THE DOOR OPEN CREATING A TRIPPING HAZZARD, CORRECT CAR FROM RE-LEVELING. CAR DOOR SLAMS OPEN IN THE OPENING CYCLE, ADJUST/REPAIR. #39167397P | Jan 22, 2026 DEFAULT | $1,562 |
| Nov 17, 2025 | Construction CLASS - 2 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39122558H, # 39122560R FOR MISCELLANEOUS VIOLATIONS ( SUSPENDED SCAFFOLD) ISSUED ON 08/20/2024, FILE A CERTIFICATE OF CORRECTION #39167312R | Jan 22, 2026 DEFAULT | $3,125 |
| Nov 17, 2025 | Construction CLASS - 2 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39122564Y ISSUED ON 08/20/2024 FOR NO RECORD OF DAILY INSPECTION OF SUSPENDED SCAFFOLD PERFORMED BY AUTHORIZED PERSON AT SITE, FILE A CERTIFICATE OF C #39167313Z | Jan 22, 2026 DEFAULT | $3,125 |
| Aug 15, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATIONS. LOCATED ON FIRST FLOOR (COMMON SPACE COVERED WITH VEN #39157286N | Apr 6, 2027 | $2,530 |
| Jun 25, 2025 | Elevators CLASS - 1 CEASE USE ITEM: FOUND EXCESSIVE GAP BETWEEN CAR DOOR AND RETURN WHEN IN THE CLOSED POSITION. CLASS 2 ITEM: ALARM BELL INOPERATIVE WHEN STOP SWITCH AND ALARM BELL BUTTON IS ANITIATED. #39151964X | Feb 18, 2027 | $1,280 |
| May 30, 2025 | Elevators CLASS - 2 CLASS 2 ITEMS: REPLACE PACKING ON HYDRAULIC JACK. CLEAN OIL THOROUGHLY ON TOP OF CAR AND A PIT. #39149388Y | Aug 7, 2025 DEFAULT | $1,562 |
| Aug 20, 2024 | Construction CLASS - 1 AT THE TIME OF MY INSPECTION THE REQUESTED INSPECTION LOGS FOR THE SUSPENDED SCAFFOLD WERE NOT PROVIDED BY THE COMPETENT PERSON ON SIGHT. AS PER BC 3314.4.3.4 THIS INSPECTION REPORTS SHALL BE MADE AVAILABLE.; 3 #39122560R | Nov 13, 2025 DEFAULT | $12,500 |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2022 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 #02390 | DOB VIOLATION - ACTIVE |
| Jul 15, 2020 | ELEVATOR #9027/685917 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 5, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 5, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2022 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022 | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Nov 5, 2026 | DOB Safety | AEUHAZ: | Open |
| Nov 5, 2026 | DOB Safety | AEUHAZ: | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Aug 27, 2026 | ECB | Unknown: UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN THE LOBBY FLEX CORDS PASSING ON THE FLOOR COVED BY CARDBOARD, THE BODY SCANNER CORD STA | Open |
| Aug 27, 2026 | ECB | Construction: AT THE TIME OF INSPECTION OBSERVED THROUGHOUT THE BUILDING IN STORAGE ROOMS BOXES STACKED TO THE CEILING BLOCKING OPERATION OF SIDE WALL SPRINKLER HEADS CONTRARY TO BC 903.3.3, REPAIR AND/REPLACE | Closed |
| Aug 27, 2026 | ECB | Construction: ATOIOBSERVED PLASTIC PVC PIPING BEING USED FOR DRAINAGE UNDER 2 COMPARTMENT SINK WITH NO TRAP INSTALLED HAVING PVC FLEXIBLE PIP DRAINING INTO A NO HUB REDUCING FITTING CONTRARY TO . PC 1002.1 & PC 706.1 ALL FIX | Open |
| Aug 27, 2026 | ECB | Unknown: FAILURE TO GROUND ELECTRICAL SYSTEMS. OBSERVED IN THE BASEMENT MAIN BUILDING WATER GROUND CLAMP IS RUSTED AND BROKEN AT THE BOLT THE GROUND WIRE IS OXIDIZE. GROUND CLAMP MUST MAINTAIN CONTIUNITY TO PROTECT ELEC | Open |
| Aug 27, 2026 | ECB | Construction: AT THE TIME OF INSPECTION OBSERVED 3 NEW HOT WATER HEATERS INSTALLED WITH OUT PERMITS CHECKED BIS/DOBNOW NO PERMITS ON FILE THE BUILDING PD SAID WASNT AWARE HE NEEDED PERMITS ALL WORK NEEDS PERMIT AND MUST BE D | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 15, 2026, 6:01 AM ET. BBL 1010350009.