| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 58 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 74 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 25,793 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 179 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 179 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 789 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-30 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 31, 2026 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY FOR VIOLATION #39174700Y. OBSERVED TRASH BINS PREVENTING EGRESS TO EMERGENCY EXIT LEADING OCCUPANTS OUT FRONT OF BUILDING IN CASE OF EMERGENCY., REMOVE OBSTRUCTIO #39202468Y | Nov 4, 2026 PENDING | $6,250 |
| Jan 21, 2026 | Construction CLASS - 3 AT TIME OF INSPECTION OBSERVED FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER AT THE REAR YARD NEAR THE STAIRCASE MASONRY STUCCO WALL IN STATE OF DISREPAIR, WALL NEED TO BE PLUMB, NOT LEANING OUT AND ALS #39174701X | Apr 1, 2026 IN VIOLATION | $500 |
| Jan 21, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED AT THE REAR YARD FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY DOOR BLOCKED WITH CARDBOARD AND TRASHCANS CREATING UNSAFE CONDITION WHEN EXITING THE BUILDING IN CASE OF EMERGENCY #39174700Y | Apr 1, 2026 IN VIOLATION | $2,500 |
| Jan 21, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION OBSERVED WORK WITHOUT ELECTRICAL PERMIT ON FILE WITH THE DOB AT EXPOSURE 3 REAR YARD AC SPLIT UNIT INSTALLED WITH ELECTRICAL DISCONNECT BOX TO PROVIDE POWER TO THE UNIT., OBTAIN PERMIT #39174699X | Apr 1, 2026 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 20, 2026 | CONSTRUCTION A STRUCTURAL STABILITY REPORT IS REQUESTED FOR APARTMENTS 20 AND 26 DUE TO OBSERVED FLOOR SLOPE AND DIFFERENTIAL ELEVATION CHANGES OCCURRING THROUGHOUT MULTIPLE AREAS OF BOTH UNITS. THE ASSESSMENT SHOULD DETERMINE WHETHER THE CONDITIONS ARE ATTRIBUTABLE TO STRUCTURAL FRAMING DISTRESS, LONG-TERM DEFL #26-00269 | DOB VIOLATION - ACTIVE |
| Apr 29, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2003294 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #23691 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Apr 29, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Mar 24, 2017 | A | Apt 1 · § 27-2005 ADM CODE REFIT ENTRANCE DOOR IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 27, 2017 |
| Mar 24, 2017 | A | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY | Jun 27, 2017 |
| Mar 24, 2017 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY | Jun 27, 2017 |
| Mar 24, 2017 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Jun 27, 2017 |
| Mar 24, 2017 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | Jun 27, 2017 |
| Mar 24, 2017 | B | Apt 1 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2017 |
| Mar 24, 2017 | B | Apt 1 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2017 |
| Mar 24, 2017 | A | Apt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 27, 2017 |
| Mar 24, 2017 | A | Apt 1 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRIC OUTLET AT EAST WALL IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 27, 2017 |
| Mar 3, 2017 | C | Apt 1 · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE UNHINGED DOOR IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 11, 2017 |
| Mar 3, 2017 | A | Apt 1 · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT WINDOW SILL IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 6, 2017 |
| Mar 3, 2017 | B | Apt 1 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF DEFECTIVE ELECTRICAL OUTLET IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 7, 2017 |
| Mar 3, 2017 | B | Apt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM EAST LOCATED AT APT 1, 1st STORY | Apr 7, 2017 |
| Mar 3, 2017 | B | Apt 1 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF DEFECTIVE GFCI OUTLET IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 7, 2017 |
| Mar 2, 2017 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING ON WALL AT PUBLIC HALL, 1st STORY | Mar 10, 2017 |
| Mar 2, 2017 | B | Apt 1 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2017 |
| Mar 2, 2017 | B | Apt 1 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2017 |
| Mar 2, 2017 | B | Apt 1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIBERGLASS PANELING AT RECESS REVEAL AT WINDOW IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2017 |
| Mar 2, 2017 | A | Apt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 5, 2017 |
| Mar 2, 2017 | A | Apt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Jun 5, 2017 |
| Mar 2, 2017 | B | Apt 1 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE (GFCI) ELECTRIC OUTLET AT NORTH WALL IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2017 |
| Oct 22, 2013 | B | SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE THE OBSTRUCTION IN FIREPROOF PASSAGEWAY GARBAGE BAGS AT FRONT WEST | Nov 26, 2013 |
| Oct 22, 2013 | B | SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. RESTORE EGRESS BY REMOVING LOCKING DEVICE AND ARRANGE TO OPEN READILY THE GATE IN FENCE AT LOT LINE AT FIRE PASSAGEWAY WEST | Nov 26, 2013 |
| Jul 27, 2009 | A | SECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX SIGN MISSING AT 1ST STORY PUBLIC HALL | Oct 30, 2009 |
| Aug 11, 2008 | A | D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CLGS PUB HALL ALL STYS. | Nov 14, 2008 |
| Oct 17, 2001 | A | Apt 15 · SECTION 27-2005 ADM CODE REFIT DOOR IN THE ENTRANCE LOCATED AT APT 15, 4th STORY | Jan 25, 2002 |
| Date | Source | What | Now |
|---|---|---|---|
| Aug 31, 2026 | ECB | Construction: FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY FOR VIOLATION #39174700Y. OBSERVED TRASH BINS PREVENTING EGRESS TO EMERGENCY EXIT LEADING OCCUPANTS OUT FRONT OF BUILDING IN CASE OF EMERGENCY., REMOVE OBSTRUCTIO | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 3, 2026, 4:11 PM ET. BBL 3024310005.