19 floors · 80,649 sq ft · built 2018 · class H2 · owner of record: Onboard Hospitality Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | Feb 21, 2027 in 99 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 80,649 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1143 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 839). Agency page | Dec 31, 2029 in 1143 days | Next due 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 10, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION FOR DEMO SIGN-OFF REQUESTED BY CONTRACTOR, UPON MY REVIEW THROUGH DOB NOW SYSTEM I OBSERVED THAT FENCE PERMIT # M00258144-I1-FN WAS EXPIRED SINCE 12-17-2020 AND NO NEW PERMIT WAS IN #39508948P | Aug 17, 2023 IN VIOLATION | $625 |
| Jun 18, 2020 | Construction CLASS - 1 JOBSITE FENCE AT TIME OF MY INSPECTION OBSERVED THAT THE JOBSITE FENCEIN PLACE AT THE VIEW PANEL OBSERVED NAIL PENETRATING THROUGH THE FENCECREATING A HAZARD FOR PASSAGEWAY TO PEOPLE TO GET INJURY WITH SHARP ED #35491645Y | Feb 4, 2021 IN VIOLATION | $2,400 |
| Issued | Violation | Status |
|---|---|---|
| Nov 6, 2026 | CONSTRUCTION BOROUGH COMMISSIONER STOP WORK ORDER APPLICATION #121332664 DUE TO CONTRACTOR WITHDRAWAL. #26-02523 | DOB VIOLATION - ACTIVE |
| Mar 31, 2014 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST #01091 | DOB VIOLATION - ACTIVE |
| Mar 31, 2014 | ELEVATOR VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPT/TST #VCAT101090 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 6, 2026 | GHG Emissions - LL97 FTF-EN-LL97320 FAILURE TO FILE AN ANNUAL BUILDINGS EMISSIONS REPORT AS REQUIRED BY AD CODE SEC. 28-320.3.7 IN ACCORDANCE WITH 1 RCNY § 103-14. | Active |
| Jul 14, 2026 | GHG Emissions - LL97 FTF-EN-LL97320 | Active |
| Mar 6, 2026 | Energy Grade - LL33 FTP-EN-EGRDEA FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER AD CODE SEC. 28-309.12.3 | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 5) | Active |
| Mar 31, 2014 | Elevators E | Active |
| Mar 31, 2014 | Elevators EVCAT1 | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Nov 6, 2026 | DOB | CONSTRUCTION: BOROUGH COMMISSIONER STOP WORK ORDER APPLICATION #121332664 DUE TO CONTRACTOR WITHDRAWAL. | Open |
| Nov 6, 2026 | DOB Safety | GHG Emissions - LL97: FAILURE TO FILE AN ANNUAL BUILDINGS EMISSIONS REPORT AS REQUIRED BY AD CODE SEC. 28-320.3.7 IN ACCORDANCE WITH 1 RCNY § 103-14. | Open |
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 8:49 AM ET. BBL 1008390067.