3 floors · 6 apartments · 4,992 sq ft · built 1922 · class C2 · owner of record: 34-17 42 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 60 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-15 (Accepted). Agency page | Dec 31, 2026 in 60 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 76 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 304 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 791 days | Next cycle year 2028 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #29596 | DOB VIOLATION - ACTIVE |
| Mar 1, 2013 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT #13582 | DOB VIOLATION - ACTIVE |
| Dec 13, 2011 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT #17934 | DOB VIOLATION - ACTIVE |
| Dec 31, 2009 | LOW PRESSURE BOILER #20910 | DOB VIOLATION - ACTIVE |
| Jun 7, 1994 | LOCAL LAW 62/91 - BOILERS #00376 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Mar 1, 2013 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2011 INSPECTION REPORT | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Dec 31, 2009 | Boiler LBLVIO | Active |
| Jun 7, 1994 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 13, 2008 | B | D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS 2 STY NORTH APT MISSING. | Sep 17, 2008 |
| Aug 13, 2008 | B | Apt 2L · D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING 2 STY APT 2L. , SECTION '' '' | Sep 17, 2008 |
| Aug 13, 2008 | B | D26-19.07 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 50 WATTS INCANDESCENT OR EQUIVALENT. | Sep 17, 2008 |
| Aug 13, 2008 | B | D26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION VESTIBULE 1 STY PUB HALL. | Sep 17, 2008 |
| Apr 25, 2006 | C | SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM , DOOR LOCKED AT CELLAR, 1st STORY | May 6, 2006 |
| Jan 30, 2006 | C | Apt 1R · SECTION 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES OVEN RANGE AT KITCHEN, 1st STORY, APARTMENT | Feb 10, 2006 |
| Jul 23, 2004 | B | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE MORTISE LOCK AT FRONT ENTRANCE | Sep 1, 2004 |
| Jul 23, 2004 | B | Apt 3R · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE TOP & BOTTOM WINDOW SASH IN THE BATHROOM LOCATED AT APT 3R, 3rd STORY, APARTMENT AT NORTH | Sep 1, 2004 |
| May 14, 2004 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT PUBLIC HALL, 2nd STORY | Jun 23, 2004 |
| Feb 9, 1999 | C | Apt 1R · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT AND OR PLASTER CEILING 1 STY APT 1R BATHROOM ER1. , SECTION '' '' | Mar 1, 1999 |
| Feb 9, 1999 | B | Apt 1R · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 1 STY APT 1R MR PRIETO. , SECTION '' '' | Mar 29, 1999 |
| Feb 9, 1999 | C | Apt 1R · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT CEILING 1 STY APT 1R KITCHEN ER1. , SECTION '' '' | Mar 1, 1999 |
| Feb 9, 1999 | C | Apt 1K · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT AND OR PLASTER WEST WALL FRONT ROOM 1 STY APT 1K MR PRIETO 718 786 3681 HARRY 3 YRS ER1. LOCATED AT APT 1K | Mar 1, 1999 |
| Feb 9, 1999 | C | Apt 1R · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT AND OR PLASTER WALLS 1 STY APT 1R BATHROOM MR PRIETO ER1. , SECTION '' '' | Mar 1, 1999 |
| Feb 9, 1999 | B | Apt 1R · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FLOOR FRONT ROOM 1 STY APT 1R. , SECTION '' '' | Mar 29, 1999 |
| Apr 23, 1996 | B | Apt 3R · SECTION 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK 3 STY SOUTH APT 3R REPAIR LEAKY ROOF THRUOUT. , SECTION '' '' | Jun 10, 1996 |
| Apr 23, 1996 | B | Apt 3R · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR 3 DTY SOUTH APT 3R WEST ROOM CEILING. , SECTION '' '' | Jun 10, 1996 |
| Apr 23, 1996 | B | Apt 3R · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR 3 STY SOUTH APT 3R REAR ROOM CEILING. , SECTION '' '' | Jun 10, 1996 |
| Apr 23, 1996 | B | Apt 3R · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR 3 STY SOUTH APT 3R BATHROOM CEILING. , SECTION '' '' | Jun 10, 1996 |
| May 21, 1991 | B | SECTION 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSE HOLD ITEMS ETC AT 3 STY PUBLIC HALL. | Jul 8, 1991 |
| May 21, 1991 | B | SECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CELLAR THROUGHOUT. | Jul 8, 1991 |
| May 21, 1991 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDED CEILING AT BOILER ROOM AND REAR SOUTH AT CELLAR. | Jul 8, 1991 |
| May 21, 1991 | B | SECTION 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES REAR STACK ALL STYS. | Jul 8, 1991 |
| Jan 8, 1991 | A | Apt 3L · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALL AND CEILING 3 STY NORTH APT 3L BATHROOM. , SECTION '' '' | Apr 26, 1991 |
| Jan 8, 1991 | B | Apt 3L · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT FIXTURE CEILING 3 STY NORTH APT 3L KITCHEN. , SECTION '' '' | Feb 25, 1991 |
| Jan 8, 1991 | A | Apt 3L · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LIGHT FIXTURE CEILING 3 STY NORTH APT 3L FRONT WEST ROOM. , SECTION '' '' | Apr 26, 1991 |
| Jan 8, 1991 | B | Apt 3L · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRE CEILING 3 STY NORTH APT 3L CENTER ROOM. , SECTION '' '' | Feb 25, 1991 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 7:46 AM ET. BBL 4006750014.