Queens · Block 4957 · Lot 43 · 11354

34-12 Union Street

2 floors · 2 apartments · 2,310 sq ft · built 1931 · class S2 · owner of record: Union 34 Assoicates

12open violations
$7,510ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 57 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-15 (Accepted). Agency page

Dec 31, 2026
in 57 days
1 of 2 without an accepted 2026 report yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1153 days
Next cycle year 2029

Open violations

ECB / OATH (7) · $7,510 owed
IssuedViolationHearingBalance
Jul 12, 2021Boilers CLASS - 2
BOILER UN REGISTERED ,IN OPEN BASEMENT NOT FIRE RATED,BLR MISSING INSULATION,NO COMBUSTION AIR ,COMBUSTIBLE MATERIAL NEAR BOILER,EXPOSED WIRES, DEBRIS ON TOP OF WARM AIR FURNACE PULLING WIRES,CORRECT ALL VIOLAT
#39044248L
Nov 16, 2021
STIPULATION/IN-VIO
$315
Oct 15, 2019Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #32097827K ISSUED ON 11-27-2018 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1 RCNY 102-01(D)(2).AN ACCEPTIBEL CERT
#37015714Y
Feb 18, 2020
DEFAULT
$3,125
Oct 15, 2019Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #32097828M ISSUED ON 11-27-2018 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1 RCNY 102-01(D)(2).AN ACCEPTIBEL CERT
#37015715X
Feb 18, 2020
DEFAULT
$3,125
Nov 27, 2018Construction CLASS - 2
FOUND (1) BURNHAM STEAM BOILER. (MDL IN7) 11/2017 DATE CODE, SERIAL #65625634 THAT WAS INSTALLED WITHOUT A PERMIT. REM: OBTAIN WORK PERMIT FOR NEW BOILER.
#32097827K
Feb 5, 2019
STIPULATION/IN-VIO
$630
Nov 27, 2018Boilers CLASS - 2
32A,36,50A,50B,50C-UNREGISTERED BURNHAM STEAM BOILER (MDL #1N7). 50A)MISSING MANUAL RESET LOW WATER CUT-OFF. 50B)MISSING PIPE INSULATION. 50C)BOILER ROOM REQUIRED. REM: CORRECT VIOLATING CONDITIONS AND SUBMIT C
#32097828M
Feb 5, 2019
STIPULATION/IN-VIO
$315
Mar 5, 2010Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER DEFECTS ARE:1)SUBSTANDARD FIRE RATING @ CELLAR BOILER & HWH AREA FOUND SHEET METAL ATTACHED TO WOOD CEILING JOISTS (NO FIRE-RATED ENCLOSURE).2)@ CELLAR REAR
#34841726R
May 4, 2010
IN VIOLATION
$0
Mar 5, 2010Construction CLASS - 2
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. PRO CERT ALT II JOB 401586734 DWG: 5.15.03. NOTED: 1) PLAN PROPOSES 2 DOORS AT STOREFRONT - FOUND 1 DOOR. 2) WALL AT KITCHEN
#34841735Z
May 4, 2010
IN VIOLATION
$0
DOB (5)
IssuedViolationStatus
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#05258
DOB VIOLATION - ACTIVE
Feb 24, 2017LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
#14716
DOB VIOLATION - ACTIVE
Mar 3, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
#17290
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#18792
DOB VIOLATION - ACTIVE
Feb 10, 1997LOCAL LAW 62/91 - BOILERS

#36556
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Feb 24, 2017Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
Active
Mar 3, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
Feb 10, 1997Boiler LL6291
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 4, 2026, 1:37 AM ET. BBL 4049570043.

Look up another building