Queens · Block 675 · Lot 21 · 11101

34-06 43 Street

3 floors · 6 apartments · 5,148 sq ft · built 1922 · class C2 · owner of record: Pocast Llc

12open violations
$0ECB/OATH penalties owed
1HPD class C (immediately hazardous)
63dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 63 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 63 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-10 (Accepted). Agency page

Dec 31, 2026
in 63 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 79 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 307 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 794 days
Next cycle year 2028

Open violations

ECB / OATH (0)

None open.

DOB (2)
IssuedViolationStatus
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#47700
DOB VIOLATION - ACTIVE
Jun 7, 1994LOCAL LAW 62/91 - BOILERS

#07875
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Aug 29, 1995Boiler LL6291
Active
Jun 7, 1994Boiler LL6291
Active
HPD (8) · C 1 · B 7 · A 0
IssuedClassViolationCorrect by
May 9, 2019BApt 2R · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE CEILING LIGHT FIXTURE IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJun 13, 2019
May 9, 2019BApt 2R · § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS SECONDARY EGRESS DOOR IN THE 2nd ROOM FROM EAST LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJun 13, 2019
May 9, 2019CApt 2R · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK INSTALLED AT DOOR LEADING TO ROOM WITH FIRE ESCAPE WINDOW IN THE 2nd ROOM FROM EAST LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMay 17, 2019
May 9, 2019BApt 2R · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJun 13, 2019
May 9, 2019BApt 2R · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJun 13, 2019
May 9, 2019BApt 2R · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJun 13, 2019
May 9, 2019BApt 2R · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJun 13, 2019
May 9, 2019B§ 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION AT CEILING LIGHT FIXTURE AT PUBLIC HALL, 2nd STORYJun 13, 2019

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 29, 2026, 7:06 AM ET. BBL 4006750021.