5 floors · 11 apartments · 10,225 sq ft · built 1900 · class C7 · owner of record: Manna House Workshops
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2015-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 43 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2022-12-27 (Accepted). Agency page | Dec 31, 2026 in 43 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 59 days | Annual |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 408 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 11, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8(2014 CODE); 27-371; BC 1008.1.9(2014 CODE); BC 1010.1.9(2022 CODE). AT TIME OF INSPECTION OF 5 STORY #39553972H | Aug 27, 2026 DEFAULT | $6,250 |
| May 11, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OF 5 STORY MIXED USE BUILDING WITH TEMPORARY CONSTRUCTION EQUIPMENT IN PLACE OBSERVED SIDEWALK SHED NOT MAINTAINED 1. ELECTRICAL NOT SECURE WITH EXPOSED WIRES, 2.EXPIRED PERMIT 3. ROTTING #39553973J | Jul 16, 2026 DEFAULT | $10,000 |
| Apr 7, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OF 4 STORY COMMERCIAL BUILDING OBSERVED SIDEWALK SHED NOT MAINTAINED PER CODE 1. LIGHTING NOT IN OPERATING CONDITION 2.LIGHTING NOT CONNECTED TO POWER SOURCE 3. PERMIT. ALL CREATING HAZARD #39552688X | Jun 11, 2026 DEFAULT | $10,000 |
| Jun 23, 2025 | Construction CLASS - 2 OBSERVED SIDEWALK SHED ERECTED AT EXPOSURE# 1 WITH DETERIORATED AND BROKEN MUDSILLS PROVIDING INADEQUATE SUPPORT FOR THE VERTICAL MEMBERS COMPROMISING THE STRUCTURAL INTEGRITY.MAINTAIN #39541621H | Aug 28, 2025 DEFAULT | $10,000 |
| Jun 4, 2025 | Construction CLASS - 2 NOTE: I OBSERVED SIDEWALK SHED ERECTED AT EXPOSURE# 1 WITH DETERIORATED AND BROKEN MUDSILLS PROVIDING INADEQUATE SUPPORT FOR THE VERTICAL MEMBERS COMPROMISING THE STRUCTURAL INTEGRITY. ALSO NOTED MISSING LIGHT #39541038K | Aug 14, 2025 DEFAULT | $10,000 |
| Jun 4, 2025 | Unknown CLASS - 2 NOTE: AT TIME OF INSPECTION, I OBSERVED SIDEWALK IN PLACE AT EXPOSURES# 1, UPON REVIEWING DEPARTMENT RECORDS (BIS/DOBNOW), IT WAS FOUND THAT THE SIDEWALK SHED PERMIT (M00460622) WAS EXPIRED ON 02/01/2022. AN AC #39541039M | Aug 14, 2025 DEFAULT | $6,250 |
| Feb 5, 2025 | Construction CLASS - 1 OBSERVED FACADE IN A STATE OF DISREPAIR WITH MISSING BRICKS AT CORNER EXPOSURE#1 AND 4, ALSO CRACKS. EXPOSURE#1 THE PARAPET HAS A GAP APPROX 3" FROM BUILDING., MAINTAIN EXTERIOR BUILDING WALL; REPAIR WALLS #39137546M | Apr 17, 2025 DEFAULT | $12,500 |
| Jan 29, 2025 | Unknown CLASS - 2 AT TIME OF INSPECTION OF 5 STORY MIXED USE BUILDING OBSERVED SIDEWALK SHED IN PLACE WITHOUT VALID PERMIT CAUSING HAZARDOUS CONDITIONS #39536404P | Apr 10, 2025 DEFAULT | $10,000 |
| Jul 2, 2024 | Unknown CLASS - 2 AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED ERECTED UPON SEARCH IN DOB NOW AND BIS SYSTEMS BOTH SHOWED PERMIT M00460622 HAS EXPIRED ON 2-01-22 AND HAS NOT BEEN RENEWED AS REQUIRED.RENEW AND MAINTAIN PERMIT I #39530196M | Sep 5, 2024 DEFAULT | $6,250 |
| Jun 18, 2024 | Unknown CLASS - 2 AT TIME OF INSPECTION OBSERVED SIDEWALK SHED AT EXPOS#1 M00460622-I1-SH-WITH PERMIT EXPIRES: 02/01/2022.. #39529727Y | Aug 22, 2024 DEFAULT | $6,250 |
| Apr 24, 2024 | Unknown CLASS - 2 AT TIME OF INSPECTION OF 5 STORY MIXED USE BUILDING OBSERVED SIDEWALK SHED IN PLACE WITHOUT VALID PERMIT. #39527970P | Jul 11, 2024 DEFAULT | $6,250 |
| Mar 15, 2024 | Construction CLASS - 2 AT TIME OF INSPECTION OF 5 STORY MIXED USE BUILDING OBSERVED SIDEWALK SHED IN PLACE WITH LIGHTING NOT IN OPERATING CONDITION CAUSING HAZARDOUS CONDITIONS.PROVIDE LIGHTING DUSK/DAWN #39526471X | May 23, 2024 DEFAULT | $10,000 |
| Mar 15, 2024 | Unknown CLASS - 2 AT TIME OF INSPECTION OF 5 STORY MIXED USE BUILDING OBSERVED SIDEWALK SHED IN PLACE WITH PERMIT #M00460622 EXPIRED 2-1-22 #39526488M | May 23, 2024 DEFAULT | $6,250 |
| Jul 13, 2023 | Construction CLASS - 2 AT TIME OF INSPECTION OF A 5 STOREYS BUILDING I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE # 1 UPON REVIEW THE DEPARTMENT RECORDS IT SHOWS THAT THE PERMIT HAD EXPIRED SINCE 02-01-2022BY COMPLY WITH CODE #39519195N | Sep 21, 2023 DEFAULT | $6,250 |
| Apr 30, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AS NOTED AT TIMEOF INSPECTION OBSERVED ON ALL FOUR EXPOSURES:DAMAGED/CRACKED MASONRY BRICKS DETERIORATING/MISSING MORTAR,VERTICAL AND STEP CRACKS,MISSING BR #35559851N | Jul 15, 2021 DEFAULT | $6,250 |
| Mar 19, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCE. NOTE: AT EXP#1 FRONT FACADE IN STATE OF DISREPAIR W/SECTION OF BRICKS HAVING FALLEN FROM 5THFL PARAPET WALL. SIDEWALK SHED INSTALLED. REMEDY: PERMIT#M00460622 EXP #35555954H | Jun 3, 2021 DEFAULT | $6,250 |
| Jan 19, 2021 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS. BUILDING EXTERIOR WALLS IN SEVERE STATE OF DISREPAIR WITH A FALLEN SECTION OF BRICKS OF APPROXIMATELY 2'X4' FEET AREA ABOVE 5TH STORY WINDOW PARAPET WALL LEVEL EXPOS #39035053R | Aug 19, 2021 DEFAULT | $12,500 |
| Jul 11, 2020 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING WALL OR APPURTENANCES.AT EXPOSURE 1(FRONT) BETWEEN 3RD+4TH FLOOR BRICK VENEER SCALING+DELANING AT VARIOUS LOCATIONS.REM:MAINTAIN EXTERIOR BUILDING WALL. #35454418L | Sep 17, 2020 DEFAULT | $6,250 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #03739 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #03690 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #15356 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION #35563 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #16023 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #36659 | DOB VIOLATION - ACTIVE |
| Jul 21, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00102 | DOB VIOLATION - ACTIVE |
| Apr 14, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00058 | DOB VIOLATION - ACTIVE |
| Apr 14, 2021 | CONSTRUCTION FTM BUILDING IN CODE COMPLIANT MANNER/EVALUATE FRAMING OF BUILDING (LEANING BULKHEAD & FRAMING/FIRE). CEILING JOIST AND COLUMNS IN BASEMENT IN SEVERE CONDITION DUE TO PREVIOUS FIRE/STAIRCASE SIGNIFANT CRACKS/BULKHEAD LEANED/CRACKS IN EXP #3. REMEDY: HIRE NYS PE TO EVAL WHOLE BLDG. OBTAIN PERMIT TO R #CEU11101GS | DOB VIOLATION - ACTIVE |
| Jan 19, 2021 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING EXTERIOR WALLS. BUILDING EXTERIOR WALLS IN SEVERE STATE OF DISREPAIR WITH A FALLEN SECTION OF BRICKS OF APPROXIMATELY 2'X4' FEET AREA ABOVE 5TH STORY WINDOW PARAPET WALL LEVEL EXPOSURE # 4. ALSO, BULGING WITH MISSING SECTIONS OF CEMENT STUCCO THROUGHOUT. PARAPET WALL EXP #21-00057 | DOB VIOLATION - ACTIVE |
| Apr 6, 2018 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT #03119 | DOB VIOLATION - ACTIVE |
| Feb 24, 2017 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT #02235 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 11) | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jul 21, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Apr 14, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Apr 6, 2018 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT | Active |
| Feb 24, 2017 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 1, 2015 | I | SECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE ?27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A V | — |
| Nov 17, 2025 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Nov 15, 2023 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Apr 1, 2021 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Oct 25, 2019 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Oct 9, 2018 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Nov 2, 2022 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Feb 15, 2022 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Nov 22, 2024 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Nov 6, 2017 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Oct 25, 2016 | I | SECTION27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE ?27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A V | — |
| Apr 29, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 2, 2026 |
| Jun 4, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 7, 2025 |
| Apr 1, 2024 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 5, 2024 |
| Mar 15, 2023 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jun 18, 2023 |
| Feb 15, 2022 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | May 21, 2022 |
| Jan 14, 2022 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT THE FIRST STORY PUBLIC HALL | Jan 20, 2022 |
| Jan 14, 2022 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. | Apr 19, 2022 |
| Jan 14, 2022 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. | Apr 19, 2022 |
| Jan 14, 2022 | A | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX AT THE FIRST STORY PUBLIC HALL | Apr 19, 2022 |
| Jan 14, 2022 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. | Apr 19, 2022 |
| Jan 14, 2022 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED | Apr 19, 2022 |
| Dec 27, 2021 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT NORTH. SOUTH, EAST AND WEST WALLS AND CEILING AT ALL STORIES AT PUBLIC HALL STAIRS | Jan 31, 2022 |
| Dec 27, 2021 | A | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. | Apr 1, 2022 |
| Dec 27, 2021 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. | Apr 1, 2022 |
| Dec 27, 2021 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. | Apr 1, 2022 |
| Dec 27, 2021 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED | Apr 1, 2022 |
| Dec 27, 2021 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. | Apr 1, 2022 |
| Dec 27, 2021 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING AT BULKHEAD | Apr 1, 2022 |
| Dec 27, 2021 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIALS AT ALL WALLS AND CEILING AT BULKHEAD | Jan 31, 2022 |
| Dec 27, 2021 | A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT NORTH, SOUTH, EAST AND WEST WALLS AND CEILING AT ALL STORIES AT PUBLIC HALL STAIRS | Apr 1, 2022 |
| Dec 27, 2021 | A | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX ... AT PUBLIC HALL, 1st STORY | Apr 1, 2022 |
| Dec 16, 2021 | A | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT SOUTH SECTION, BUILDING FRONT AT FIRE ESCAPE | Mar 21, 2022 |
| Dec 15, 2021 | C | § 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS. | Dec 19, 2021 |
| Dec 8, 2021 | C | Apt 16 · § 27-2056.7 ADM CODE: CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES. | Dec 12, 2021 |
| Apr 1, 2021 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 5, 2021 |
| Feb 6, 2017 | A | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT BUILDING FRONT FIRE ESCAPE | May 12, 2017 |
| Jun 22, 2015 | A | SECTION 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT BUILDING FRONT STACK AT FIRE ESCAPE, 1st STORY | Sep 25, 2015 |
| Jun 12, 2015 | A | SECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT LOBBY, 1st STORY | Sep 15, 2015 |
| Jun 12, 2015 | B | Apt 17 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 17, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 17, 2015 |
| Jun 12, 2015 | B | Apt 17 · SECTION 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 17, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 17, 2015 |
| Mar 19, 2015 | A | SECTION 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCY?S HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Jun 22, 2015 |
| Sep 10, 2008 | A | SECTION 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT FRONT FIRE ESCAPE | Dec 14, 2008 |
| Jun 19, 2008 | B | D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT YARD. | Jul 24, 2008 |
| Jun 19, 2008 | A | D26-12.03 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT FRONT FIRE ESCAPES ALL STYS. | Sep 22, 2008 |
| Jun 19, 2008 | A | D26-12.03 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT REAR FIRE ESCAPES ALL STYS. | Sep 22, 2008 |
| Jun 19, 2008 | A | SECTION 62 M/D LAW REARRANGE TELEVISION AND/OR RADIO ANTENNA TO BE AT LEAST 10 FEET ABOVE ROOF AND NOT ATTACHED TO ANY FIRE ESCAPE OR SOIL OR VENT LINE ROOF CENTER EAST AND REAR FIRE ESCAPE. | Sep 22, 2008 |
| Jun 19, 2008 | A | D26-11.01, 11.03, 11.05 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE REAR YARD. | Sep 22, 2008 |
| Jun 19, 2008 | A | D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PAVING AT REAR YARD. | Sep 22, 2008 |
| Jun 19, 2008 | B | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRIC WIRE CELLAR CEILING THROUGHOUT. | Jul 24, 2008 |
| Mar 13, 2006 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT PUBLIC HALL, 1st STORY | Apr 22, 2006 |
| Jan 10, 2006 | A | SECTION 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | Apr 20, 2006 |
| Jan 10, 2006 | A | SECTION 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY | Apr 20, 2006 |
| Jan 10, 2006 | A | SECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX ... AT PUBLIC HALL, 1st STORY | Apr 20, 2006 |
| Jan 10, 2006 | B | Apt 9 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR .... IN THE ENTIRE APARTMENT LOCATED AT APT 9, 3rd STORY, APARTMENT AT EAST | Feb 19, 2006 |
| Dec 21, 2005 | A | SECTION 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER (MISSING) AT NORTH FIRE ESCAPE , 1st STORY | Mar 31, 2006 |
| Apr 22, 2003 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAIL BOX LOCKS AT LAUNDRY ROOM, 1st STORY | Jun 1, 2003 |
| Apr 22, 2003 | C | Apt 13 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 13, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | May 3, 2003 |
| Apr 22, 2003 | B | Apt 13 · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS AT TOP AND BOTTOM SASHES IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 13, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 1, 2003 |
| Apr 22, 2003 | B | Apt 13 · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE IN THE ENTIRE APARTMENT LOCATED AT APT 13, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 1, 2003 |
Showing 60 of 79. Full list on the agency site.